{"title":"Serial-to-Ethernet Device Servers","description":"\u003cp\u003eTurn any RS232, RS422, or RS485 serial device into a networked device — accessible and controllable over standard 10\/100 Ethernet from anywhere on your network. A cost-effective way to modernize legacy serial equipment for remote access, monitoring, and centralized management.\u003c\/p\u003e","products":[{"product_id":"csw-h85n-serial-to-wifi-device-server","title":"CSW-H85N Serial RS232 \/ RS422 \/ RS485 to WiFi Network Device Server","description":"\u003cp\u003eThe EZTCP CSW-H85N by Sollae Systems is an RS-232 \/ RS-422 \/ RS-485 serial to wireless LAN (WiFi) adapter that enables you to add wireless networking capabilities to your industrial equipment via RS232, RS422 and RS485.\u003c\/p\u003e\n\u003cp\u003eBy applying this serial to wireless LAN adapter, you can control and monitor your serial devices from anywhere in the world over wireless LAN. The CSW-H85N comes preloaded with Soft AP so that it can simply be linked to any devices with wireless LAN by operating as a virtual AP. Thanks to this feature, it makes it easier for you to construct networks with mobile devices such as smartphones, tablet PCs and laptops where a wireless LAN network is inaccessible.\u003c\/p\u003e\n\u003cp\u003eThis serial to wireless LAN adapter offers enhanced security protocol, WPA Enterprise for business purposes to ensure high protection and reliability. With infrastructure and Ad-hoc networking provided, this serial to wireless LAN adapter can be used for various wireless applications such as: Internet Signboards, Energy Management, and Medical Monitoring.\u003c\/p\u003e\n\u003ch4\u003eFeatures:\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eIEEE 802.11 b\/g\u003c\/li\u003e\n\u003cli\u003eSoft AP (setting and connection through a smart phone or laptop without an AP available)\u003c\/li\u003e\n\u003cli\u003eSetting up main parameters (IP, SSID and security functions related to WLAN) on the Web\u003c\/li\u003e\n\u003cli\u003eMulti-Monitoring (maximum 4 channels)\u003c\/li\u003e\n\u003cli\u003eSSL (Secure Sockets Layer)\u003c\/li\u003e\n\u003cli\u003eIPv4 \/ IPv6 dual stack\u003c\/li\u003e\n\u003cli\u003eWPA Enterprise (EAP-TLS, EAP-TTLS, PEAP)\u003c\/li\u003e\n\u003cli\u003eSeparator settings for packet fragmentation\u003c\/li\u003e\n\u003cli\u003e2dBi dipole antenna, Reverse Polarity SMA connector for external antennas\u003c\/li\u003e\n\u003cli\u003eSerial to wireless LAN adapter with RS232\/RS422\/RS485 interface\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSpecifications:\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eSerial Physical Interface\u003c\/li\u003e\n\u003cul\u003e\n\u003cli\u003eSerial Interface RS232 - RXD, TXD, RTS, CTS, DTR, DSR, GND\u003c\/li\u003e\n\u003cli\u003eRS422 - RX+, RX-, TX+, TX-, GND\u003c\/li\u003e\n\u003cli\u003eRS485 - TRX+, TRX-, GND\u003c\/li\u003e\n\u003cli\u003e±15KV ESD Protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003eSerial Port Property\u003c\/li\u003e\n\u003cul\u003e\n\u003cli\u003eBaudrate 300bps ~ 230,400bps\u003c\/li\u003e\n\u003cli\u003eData Bits 8 bits, 7 bits with Parity\u003c\/li\u003e\n\u003cli\u003eParity None, Even, Odd, Mark, Space\u003c\/li\u003e\n\u003cli\u003eStop Bit 1, 1.5, 2\u003c\/li\u003e\n\u003cli\u003eFlow Control RTS\/CTS (Hardware), Xon\/Xoff (Software)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003eNetwork Interface\u003c\/li\u003e\n\u003cul\u003e\n\u003cli\u003eWireless LAN Interface IEEE802.11b\/g Wireless LAN\u003c\/li\u003e\n\u003cli\u003eSupplied with a dipole 2dBi Antenna\u003c\/li\u003e\n\u003cli\u003eReverse Polarity SMA connector for external antennas\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003eSoftware Functions\u003c\/li\u003e\n\u003cul\u003e\n\u003cli\u003eWireless LAN Mode Ad-Hoc, Infrastructure\u003c\/li\u003e\n\u003cli\u003eSoft AP: WEP, Simple DHCP Server\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003eProtocols\u003c\/li\u003e\n\u003cul\u003e\n\u003cli\u003eIPv4\/IPv6 Dual Stack, ICMPv6\/TCPv6\/UDPv6\u003cbr\u003eTCP, UDP, IP, ICMP, ARP, TELNET\u003cbr\u003eDHCP, DNS, DDNS\u003cbr\u003eTELNET COM Port Control Option (RFC 2217)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003eSecurity\u003c\/li\u003e\n\u003cul\u003e\n\u003cli\u003eWEP, WPA-PSK, WPA2-PSK\u003c\/li\u003e\n\u003cli\u003eWPA-Enterprise: EAP-TLS, EAP-TTLS, PEAP\u003c\/li\u003e\n\u003cli\u003eSSL(Secure Socket Layer)\u003c\/li\u003e\n\u003cli\u003eIP \u0026amp; MAC Filtering - Restrict Host or Network\u003c\/li\u003e\n\u003cli\u003ePassword for Configuring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003eCommunication Mode\u003c\/li\u003e\n\u003cul\u003e\n\u003cli\u003eTCP Server (T2S)\u003c\/li\u003e\n\u003cli\u003eTCP Client (COD)\u003c\/li\u003e\n\u003cli\u003eTCP Server\/Client with AT Command (ATC) - Patent\u003c\/li\u003e\n\u003cli\u003eUDP Mode (U2S)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003eAdditional Functions\u003c\/li\u003e\n\u003cul\u003e\n\u003cli\u003eDebug Function\u003c\/li\u003e\n\u003cli\u003eMulti Monitoring(Maximum 4 TCP connections simultaneously)\u003c\/li\u003e\n\u003cli\u003eTCP Server \/ Client Mode\u003c\/li\u003e\n\u003cli\u003eSeparator settings for packet fragmentation\u003c\/li\u003e\n\u003cli\u003eFirmware upgrade via Network\u003c\/li\u003e\n\u003cli\u003eSending MAC address Option\u003c\/li\u003e\n\u003cli\u003eFactory Reset\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003eIndicators (LEDs)\u003c\/li\u003e\n\u003cul\u003e\n\u003cli\u003ePower Red\u003c\/li\u003e\n\u003cli\u003eStatus Yellow, The current status\u003c\/li\u003e\n\u003cli\u003eWireless LAN Link Green\u003c\/li\u003e\n\u003cli\u003eWireless LAN RXD Yellow\u003c\/li\u003e\n\u003cli\u003eWireless LAN TXD Green\u003c\/li\u003e\n\u003cli\u003eSerial RXD Yellow\u003c\/li\u003e\n\u003cli\u003eSerial TXD Green\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003eManagement:\u003c\/li\u003e\n\u003cul\u003e\n\u003cli\u003eezManager Configuration and Monitoring through Network and Serial\u003c\/li\u003e\n\u003cli\u003eTELNET TELNET Login\u003c\/li\u003e\n\u003cli\u003eAT Command Configuring in ATC Mode - Patent\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003eSupplementary Software\u003c\/li\u003e\n\u003cul\u003e\n\u003cli\u003eezManager Configuration Tool for Windows through Network and serial\u003c\/li\u003e\n\u003cli\u003eezVSP Serial to Network Virtual Driver for Windows\u003c\/li\u003e\n\u003cli\u003eezTerm Simple TCP\/IP Communication Test Tool\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003eDimensions\u003c\/li\u003e\n\u003cul\u003e\n\u003cli\u003eSize 88.5mm x 57.0mm x 23.0mm (Without an Antenna)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003eOperating Environments\u003c\/li\u003e\n\u003cul\u003e\n\u003cli\u003eInput Voltage DC 5±0.5V\u003c\/li\u003e\n\u003cli\u003eCurrent Consumption 210mA Typical\u003c\/li\u003e\n\u003cli\u003eOperating Temperature -20℃ ~ +60℃\u003c\/li\u003e\n\u003cli\u003eStorage Temperature -40℃ ~ +60℃\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003eCertifications\u003c\/li\u003e\n\u003cul\u003e\n\u003cli\u003eKC Certificate(KN 301 489-1, KN 301 489-17, KN 32, KN 35, KS X 3123:2018)\u003c\/li\u003e\n\u003cli\u003eCE RED 2014\/53\/EU, RoHS 2011\/65\/EU\u003c\/li\u003e\n\u003cli\u003eFCC FCC Part 15 Subpart C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e Package includes:\u003c\/h4\u003e\n\u003cdiv style=\"padding-left: 30px;\"\u003e1X CSW-H85N Serial WLAN Device Server\u003cbr\u003e1X Dipole Antenna\u003c\/div\u003e\n\u003cdiv style=\"padding-left: 30px;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eDelivery is\u003cspan\u003e \u003c\/span\u003estock\u003cspan\u003e \u003c\/span\u003eto 2 weeks, please contact us prior to ordering for availability.\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\n\u003c\/div\u003e\n\u003ch4\u003e\n\u003cbr\u003eDocumentation \u0026amp; Resources:\u003c\/h4\u003e\n\u003cdiv\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/www.eztcp.com\/en\/products\/csw-h85n.php\" title=\"EZTCP CSW-H85N \/ Serial WLAN Device Server Web Page\" target=\"_blank\"\u003eEZTCP CSW-H85N \/ Serial WLAN Device Server Web Page\u003c\/a\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/www.eztcp.com\/en\/download\/utility.php\" title=\"EZTCP Utility Downloads\" target=\"_blank\"\u003eEZTCP Utility Downloads\u003c\/a\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/www.eztcp.com\/en\/download\/pds_files\/cswh85nen.pdf\" title=\"EZTCP CSW-H85N Serial WLAN Device Server User Manual\" target=\"_blank\"\u003eEZTCP CSW-H85N Serial WLAN Device Server User Manual\u003c\/a\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cbr\u003eVideos:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eCSW-H85N Introductory video\u003c\/p\u003e\n\u003cp\u003e\u003ciframe width=\"560\" height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/pjtJzZHV56s\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e","brand":"Sollae Systems","offers":[{"title":"Default Title","offer_id":14006828892244,"sku":"CSW-H85N-BO","price":192.56,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1641\/0911\/products\/csw-h85n-serial-wlan-device-server-210683.jpg?v=1594221431"},{"product_id":"cse-h53n-industrial-rs232-ethernet-device-server","title":"Sollae Systems ezTCP CSE-H53N Industrial RS-232 to Ethernet Converter","description":"\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eTransform your RS-232 serial devices into network-ready equipment with industrial-grade reliability and advanced IPv4 and IPv6 support.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eThe Sollae Systems ezTCP CSE-H53N is an industrial-grade RS232 serial-to-Ethernet converter designed for demanding environments. With support for both IPv4 and IPv6, industrial temperature range (-40°C to +85°C), and advanced features like SSL\/TLS security and multiple simultaneous connections, the CSE-H53N delivers enterprise-level performance for mission-critical applications.\u003c\/p\u003e\n\u003chr class=\"my-7 border-neutral-300 dark:border-neutral-700\"\u003e\n\u003ch2 class=\"mb-2 mt-4 break-words text-xl font-semibold\"\u003eWhy Choose the CSE-H53N?\u003c\/h2\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e🌐\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eFuture-Proof IPv6 Support\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eFull IPv4\/IPv6 dual stack implementation with stateless and stateful (DHCPv6) address auto-configuration. Ready for modern networks and future IPv6 deployments.\u003c\/p\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e🏭\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eIndustrial-Grade Reliability\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eExtreme temperature range (-40°C to +85°C) and robust design make this converter perfect for harsh industrial environments where consumer-grade equipment fails.\u003c\/p\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e🔒\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eEnterprise Security\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eBuilt-in SSL\/TLS encryption, IP\/MAC filtering, and password protection ensure your serial data remains secure across the network.\u003c\/p\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e🔄\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eMultiple Connection Support\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eMonitor and control from multiple locations simultaneously. Multiple clients can connect to a single CSE-H53N for distributed monitoring and control applications (firmware v2.3A or later).\u003c\/p\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e⚡\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eHigh-Speed Performance\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eRS-232 support up to 230.4 kbps ensures fast, reliable data transfer for even the most demanding serial applications.\u003c\/p\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e🎯\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eFlexible Configuration\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eConfigure via Ethernet (ezManager), serial port, AT commands, or Telnet. Choose the method that works best for your deployment scenario.\u003c\/p\u003e\n\u003chr class=\"my-7 border-neutral-300 dark:border-neutral-700\"\u003e\n\u003ch2 class=\"mb-2 mt-4 break-words text-xl font-semibold\"\u003eCSE-H53N Technical Specifications\u003c\/h2\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003eSerial Interface\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003ePhysical Interface:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003ePort:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e1 x RS-232 (DB9 Male connector)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eSignals:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eRXD, TXD, GND, RTS, CTS, DTR, DSR\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eMaximum Baud Rate:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e230.4 kbps\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eSupported Baud Rates:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e300, 600, 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200, 230400 bps\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eSerial Parameters:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eData Bits:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e8 bits, 7 bits (with parity)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eParity:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eNone, Even, Odd, Mark, Space\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eStop Bits:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e1, 1.5, 2\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eFlow Control:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eNone, RTS\/CTS, XON\/XOFF\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003ePin Assignment (DB9 Male):\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003ePin 2:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eRXD (Receive Data) - Input\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003ePin 3:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eTXD (Transmit Data) - Output\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003ePin 4:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eDTR (Data Terminal Ready) - Output (Active during TCP connection)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003ePin 5:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eGND (Ground)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003ePin 6:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eDSR (Data Set Ready) - Input\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003ePin 7:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eRTS (Request To Send) - Output\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003ePin 8:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eCTS (Clear To Send) - Input\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003eNetwork Interface\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eEthernet:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003ePort:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e1 x RJ-45 (10\/100 Mbps)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eSpeed:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e10Base-T or 100Base-TX (Auto-Sensing)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eCable Detection:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eAuto MDI\/MDIX (works with straight or crossover cables)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eConnector LEDs:\u003c\/span\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eGreen: Link status (On = connected, Blink = data activity)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eYellow: Speed indicator (Off = 10Mbps, On = 100Mbps)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eNetwork Protocols:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eIPv4:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eTCP, UDP, IP, ICMP, ARP, DHCP, PPPoE, DNS, DDNS\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eIPv6:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eICMPv6, TCPv6, UDPv6, IPv6 fragmentation\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eIPv6 Configuration:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eStateless and Stateful (DHCPv6) auto-configuration\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eManagement:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eTelnet, HTTP (ezManager)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eAdvanced:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eTelnet COM Port Control Option (RFC 2217)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003eCommunication Modes\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eTCP Server (T2S):\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003ePassive connection mode\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eWaits for incoming TCP client connections\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eDefault local port: 1470\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eIdeal for centralized monitoring applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eTCP Client (COD):\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eActive connection mode\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eInitiates connection to remote TCP server\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eConfigurable peer IP address and port\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003ePerfect for data logging and cloud integration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eAT Command Mode (ATC):\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eControl connections dynamically via AT commands\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eBoth active and passive connections supported\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eAllows runtime configuration changes\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003ePatented Sollae Systems technology\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eUDP Mode (U2S):\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eConnectionless communication\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eBroadcast and multicast support\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eLow-latency data transfer\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eN:M topology (many-to-many communication)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003ePower Specifications\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eInput Voltage:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eDC 5V ±0.5V (±10%)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eCurrent Consumption:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e200mA typical\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003ePower Connector:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eDC jack (Outer: Ø3.5mm, Inner: Ø1.35mm)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eProtection:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eOver-current, reverse voltage, and surge protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003eEnvironmental Specifications\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eOperating Temperature:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e-40°C to +85°C (-40°F to 185°F)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eStorage Temperature:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e-40°C to +85°C\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eHumidity:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e5% to 95% RH, non-condensing\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eCertifications:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eKC, CE, FCC Class A, RoHS compliant\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003ePhysical Specifications\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eDimensions:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e89mm (W) x 57mm (L) x 24mm (H) (3.5\" x 2.24\" x 0.94\")\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eWeight:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eApproximately 65g (2.3 oz)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eMounting:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eDesktop (compact footprint)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eEnclosure:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eIndustrial-grade plastic housing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003eStatus Indicators (LEDs)\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eTop Panel LEDs:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003ePWR (Red):\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003ePower indicator (On = power supplied)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eSTS (Yellow):\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eStatus indicator\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eBlinks every second = Obtaining IP address\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eBlinks 4 times = No IP address (DHCP\/PPPoE failure)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eOn = TCP connection established\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eOff = ISP mode\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSimultaneous blink with LINK\/RXD\/TXD = Serial Configuration mode\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eLINK (Green):\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eEthernet link status (On = connected)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eRXD (Yellow):\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eEthernet receive activity (Blinks = receiving data)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eTXD (Green):\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eEthernet transmit activity (Blinks = transmitting data)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eSerial Activity LEDs:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eSerial RXD (Yellow):\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eSerial receive activity\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eSerial TXD (Green):\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eSerial transmit activity\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr class=\"my-7 border-neutral-300 dark:border-neutral-700\"\u003e\n\u003ch2 class=\"mb-2 mt-4 break-words text-xl font-semibold\"\u003eReal-World Applications\u003c\/h2\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e🏭\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eIndustrial Automation \u0026amp; SCADA\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eConnect PLCs, RTUs, and industrial controllers to SCADA systems\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eRemote monitoring and control of manufacturing equipment\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eBuilding automation and energy management\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eFactory floor data collection and distribution\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eProcess control and monitoring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e🏥\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eHealthcare \u0026amp; Medical Equipment\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eNetwork legacy diagnostic equipment and patient monitors\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eLaboratory automation and LIMS integration\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eMedical imaging device connectivity\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eHospital infrastructure management\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eRemote equipment monitoring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e🚂\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eTransportation \u0026amp; Infrastructure\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eRailway signaling and control systems\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eTraffic management and ITS applications\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eAirport ground support equipment\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eParking management and access control\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eFleet management systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e⚡\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eEnergy \u0026amp; Utilities\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eSmart grid monitoring and control\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSubstation automation\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eRemote meter reading (AMR\/AMI)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003ePower distribution management\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eEnvironmental monitoring stations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e📡\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eTelecommunications\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eSerial console access to network equipment\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eRemote management of telecom infrastructure\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eBase station monitoring and control\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eNetwork operations center (NOC) equipment\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e🔬\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eLaboratory \u0026amp; Research\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eNetwork analytical instruments and data loggers\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eAutomated testing equipment\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eQuality control systems\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eResearch data acquisition\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eEnvironmental monitoring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e🏗️\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eSecurity \u0026amp; Access Control\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eCard readers and access control panels\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eCCTV camera control (PTZ)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eIntrusion detection systems\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eFire alarm panels\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eBiometric sensors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e💻\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eIT Infrastructure\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eSerial console servers\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eOut-of-band management\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eKVM over IP applications\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eNetwork equipment management\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eServer room monitoring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAs well as industrial environments, the CSE-H53N is ideal for diverse applications such as \u003ca href=\"https:\/\/www.eztcp.com\/en\/applications\/internet-signboard\" title=\"Advertisement Systems (LED Signboards over Internet)\" target=\"_blank\"\u003eAdvertisement Systems (LED Signboards over Internet)\u003c\/a\u003e, \u003ca href=\"https:\/\/www.eztcp.com\/en\/applications\/remote-console\" title=\"Remote Console Monitoring\" target=\"_blank\"\u003eRemote Console Monitoring\u003c\/a\u003e, and \u003ca href=\"https:\/\/www.eztcp.com\/en\/applications\/plc-control\" title=\"Control PLC Over The Internet\" target=\"_blank\"\u003eControl PLC over Internet\u003c\/a\u003e.\u003c\/p\u003e\n\u003chr class=\"my-7 border-neutral-300 dark:border-neutral-700\"\u003e\n\u003ch2 class=\"mb-2 mt-4 break-words text-xl font-semibold\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e✓\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eCSE-H53N Serial to Ethernet Converter\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e(1 unit)\u003cbr\u003e✓\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eQuick Start Guide\u003c\/span\u003e\u003cbr\u003e✓\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eSoftware available for download:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003eezManager (Configuration utility for Windows)\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003eezVSP (Virtual Serial Port driver for Windows)\u003c\/li\u003e\n\u003cli\u003eezTerm (TCP\/IP communication test tool)\u003c\/li\u003e\n\u003cli\u003eUser manual (PDF)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cem class=\"italic\"\u003eAll software is available for download from the Sollae Systems ezTCP website. See the link under the \u003cstrong\u003eTechnical Support \u0026amp; Resources\u003c\/strong\u003e section below.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eOptional Accessories\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/envistiamall.com\/products\/ac-dc-wall-mount-adapter-5v-5w-dc-power-connector\" title=\"AC\/DC WALL MOUNT ADAPTER 5V 5W W\/ 2.1MM X 5.5MM DC OUTPUT CONNECTOR\" rel=\"noopener\" target=\"_blank\"\u003e+5V AC\/DC Wall Mount Power Supply\u003c\/a\u003e\u003c\/p\u003e\n\u003chr class=\"my-7 border-neutral-300 dark:border-neutral-700\"\u003e\n\u003ch2 class=\"mb-2 mt-4 break-words text-xl font-semibold\"\u003eQuick Setup Guide\u003c\/h2\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eStep 1: Physical Connections\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eConnect your RS-232 device to the DB9 Male port\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eConnect Ethernet cable to your network (straight or crossover - auto-detected)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eConnect 5V DC power adapter\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003ePWR LED will illuminate when powered on\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eStep 2: Network Configuration\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eDefault Settings:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eIP Address:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e10.1.0.1\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eSubnet Mask:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e255.0.0.0\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eLocal Port:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e1470\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eCommunication Mode:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eTCP Server\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eBaud Rate:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e19,200 bps\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eData Format:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e8-N-1 (8 data bits, No parity, 1 stop bit)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cstrong\u003e\u003cspan class=\"font-semibold\"\u003eConfiguration Methods:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eOption A - ezManager (Recommended):\u003c\/span\u003e\u003c\/p\u003e\n\u003col class=\"ml-8 list-outside list-decimal\"\u003e\n\u003cli class=\"py-0.5\"\u003eDownload and run ezManager (no installation required)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eClick [Search All] to discover CSE-H53N on your network\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSelect the device by MAC address\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eConfigure network and serial parameters\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eClick [Write] to save settings\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eDevice will reboot automatically\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eOption B - Serial Configuration:\u003c\/span\u003e\u003c\/p\u003e\n\u003col class=\"ml-8 list-outside list-decimal\"\u003e\n\u003cli class=\"py-0.5\"\u003eConnect RS-232 cable between PC and CSE-H53N\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003ePress function button for 1-3 seconds to enter Serial Configuration mode\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eOpen ezManager, select [Serial] tab\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSelect COM port and click [Open]\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eClick [Read] to load current settings\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eModify parameters as needed\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eClick [Write] to save\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eOption C - AT Commands:\u003c\/span\u003e\u003c\/p\u003e\n\u003col class=\"ml-8 list-outside list-decimal\"\u003e\n\u003cli class=\"py-0.5\"\u003eSet communication mode to \"AT Command\" via ezManager\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eConnect via serial terminal (115,200 bps, 8-N-1)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eUse AT commands to configure parameters\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSave with AT+PWP command\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eStep 3: Test Communication\u003c\/span\u003e\u003c\/h3\u003e\n\u003col class=\"ml-8 list-outside list-decimal\"\u003e\n\u003cli class=\"py-0.5\"\u003eUse ezManager's [Simple Test] feature\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eConfigure TCP connection (IP address and port)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eOpen serial port with matching parameters\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSend test data in both directions to verify operation\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eTotal setup time: 5-10 minutes\u003c\/span\u003e\u003c\/p\u003e\n\u003chr class=\"my-7 border-neutral-300 dark:border-neutral-700\"\u003e\n\u003ch2 class=\"mb-2 mt-4 break-words text-xl font-semibold\"\u003eAdvanced Features \u0026amp; Capabilities\u003c\/h2\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eIPv6 Dual Stack Implementation\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eThe CSE-H53N is fully IPv6-ready with comprehensive support:\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eIPv6 Features:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eFull IPv4\/IPv6 dual stack operation\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eStateless address auto-configuration (SLAAC)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eStateful address configuration (DHCPv6)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eIPv6 fragmentation support\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eICMPv6, TCPv6, UDPv6 protocols\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSeamless IPv4\/IPv6 interoperability\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eWhy IPv6 Matters:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eFuture-proof your infrastructure\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eLarger address space eliminates NAT complexity\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eImproved security with IPsec integration\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eBetter support for mobile and IoT devices\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSimplified network configuration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eMultiple Connection Support\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eSimultaneous Monitoring (Firmware v2.3A+):\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eMultiple TCP clients can connect to one CSE-H53N simultaneously\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003ePerfect for distributed monitoring applications\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eEach client receives the same serial data\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eIdeal for redundant monitoring systems\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eNo additional hardware required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eUse Cases:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eMultiple operators monitoring the same equipment\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eRedundant data logging systems\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eDistributed SCADA architectures\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eMulti-site monitoring applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eSSL\/TLS Security\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eSecure Socket Layer Protection:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eEncrypt serial data over the network\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eProtect sensitive information in transit\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eIndustry-standard SSL\/TLS protocols\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eCertificate-based authentication\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003ePrevents eavesdropping and tampering\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eSecurity Features:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eIP address filtering (whitelist\/blacklist)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eMAC address filtering\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003ePassword-protected configuration\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSecure firmware updates\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eAccess control lists\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003ePacket Fragmentation Control\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eSeparator Settings:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eDefine custom packet delimiters\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eControl when data is transmitted over network\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eOptimize for different protocols and applications\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eReduce network overhead\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eImprove application-level parsing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eData Frame Interval:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eConfigure timeout for packet assembly\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eBalance real-time performance vs. network efficiency\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eAdjustable from 0ms (immediate) to custom values\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eOptimize for your specific application\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eTelnet COM Port Control (RFC 2217)\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eRemote Serial Port Control:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eChange serial parameters remotely over network\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eAdjust baud rate, parity, data bits, stop bits\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eControl flow control settings\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eMonitor serial port status\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eNo physical access required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eBenefits:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eRemote troubleshooting and diagnostics\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eDynamic serial parameter adjustment\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eCentralized serial port management\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eReduced site visits and maintenance costs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eDynamic DNS (DDNS) Support\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eAlways Accessible:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eAutomatic DNS updates when IP address changes\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eUse hostname instead of IP address\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003ePerfect for dynamic IP environments\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSupports major DDNS providers\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSimplified remote access\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003ePPPoE Support\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eDirect Internet Connection:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eConnect directly to DSL\/cable modems\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eNo router required for simple deployments\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eAutomatic authentication and connection\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eIdeal for remote installations\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eReduced hardware costs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eAT Command Mode\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003ePatented Dynamic Control:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eChange connection parameters at runtime\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eEstablish\/terminate connections via serial commands\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eNo device reboot required\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003ePerfect for applications requiring dynamic connectivity\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eUnique Sollae Systems technology\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eAT Command Capabilities:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eConfigure IP addresses and ports\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eEstablish TCP connections\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eControl DHCP and PPPoE\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSet DNS servers\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eModify timeout values\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSave settings to flash memory\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr class=\"my-7 border-neutral-300 dark:border-neutral-700\"\u003e\n\u003ch2 class=\"mb-2 mt-4 break-words text-xl font-semibold\"\u003eSoftware Suite\u003c\/h2\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eezManager - Configuration Utility\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eComprehensive Management Tool for Windows:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eFeatures:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eNo installation required (portable application)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eAutomatic device discovery via MAC or IP address\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eIntuitive graphical interface\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eReal-time status monitoring\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eFirmware update management\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eConfiguration backup and restore\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSimple test utility included\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eBatch configuration for multiple devices\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eConfiguration Methods:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eVia Ethernet (LAN)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eVia Serial port\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eRemote configuration via Telnet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eezVSP - Virtual Serial Port Driver\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eWindows Virtual COM Port Driver:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eFeatures:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eCreates virtual COM ports on Windows PC\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eLegacy applications work without modification\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSupports multiple virtual ports\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eAutomatic reconnection on network interruption\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eCompatible with Windows 7\/8\/10\/11\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eNo application changes required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eHow It Works:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eThe CSE-H53N appears as a local COM port on your Windows PC. Your existing serial software communicates with the virtual port, and ezVSP handles all network communication transparently.\u003c\/p\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eezTerm - Communication Test Tool\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eSimple TCP\/IP Testing:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eFeatures:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eQuick TCP\/IP communication testing\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eBoth TCP and UDP support\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eServer and client modes\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eHex and ASCII data display\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eData logging capabilities\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003ePerfect for troubleshooting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eSmartphone Applications\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eMobile Configuration:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eezManager app available for iOS and Android\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eConfigure devices from your smartphone or tablet\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eMonitor status remotely\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003ePerfect for field installations\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eFree download from app stores\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr class=\"my-7 border-neutral-300 dark:border-neutral-700\"\u003e\n\u003ch2 class=\"mb-2 mt-4 break-words text-xl font-semibold\"\u003eOperation Modes\u003c\/h2\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eNormal Mode\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eStandard Operation:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eFor normal data communication\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eFour communication modes available (TCP Server, TCP Client, AT Command, UDP)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eConfiguration via ezManager or Telnet\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eReal-time status monitoring\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eDefault operating mode\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eSerial Configuration Mode\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eSerial Port Configuration:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eConfigure via RS-232 port\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSerial parameters: 115,200 bps, 8-N-1\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eUse ezManager Serial tab\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eNo network connection required\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003ePerfect for initial setup or network troubleshooting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eHow to Enter:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003ePress function button for 1-3 seconds\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eAll LEDs (STS, LINK, RXD, TXD) blink simultaneously\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eConnect via serial port at 115,200 bps\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eISP Mode (In-System Programming)\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eFirmware Updates:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eFor upgrading firmware\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eBypass security settings (password recovery)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eDirect firmware upload via ezManager\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eFactory reset capability\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eEmergency recovery mode\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eHow to Enter:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003ePress function button for more than 3 seconds during power-on\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSTS LED turns off\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eUpload firmware via ezManager\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr class=\"my-7 border-neutral-300 dark:border-neutral-700\"\u003e\n\u003ch2 class=\"mb-2 mt-4 break-words text-xl font-semibold\"\u003eNetwork Topology Examples\u003c\/h2\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003e1:1 Direct Connection\u003c\/span\u003e\u003c\/h3\u003e\n\u003cdiv class=\"my-4 w-full max-w-full overflow-hidden\"\u003e\u003ccode class=\"rounded bg-muted px-1 py-0.5 font-mono text-sm\"\u003e[PC] ←→ [CSE-H53N] ←→ [Serial Device]\u003c\/code\u003e\u003c\/div\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eSimple point-to-point connection for testing or isolated systems.\u003c\/p\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eLAN Integration\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"font-semibold\"\u003e[Network Switch] ←→ [CSE-H53N] ←→ [Serial Device]\u003cbr\u003e                 ←→ [PC 1]\u003cbr\u003e                 ←→ [PC 2]\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"my-4 w-full max-w-full overflow-hidden\"\u003e\n\u003cdiv class=\"code-block group relative my-1 rounded-[18px] overflow-hidden bg-muted\"\u003e\n\u003cdiv class=\"flex items-center justify-between px-3 py-2 bg-[#f5f5f7]\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eMultiple PCs access one serial device over local network.\u003c\/p\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eInternet Access via Router\u003c\/span\u003e\u003c\/h3\u003e\n\u003cdiv class=\"my-4 w-full max-w-full overflow-hidden\"\u003e\u003ccode class=\"rounded bg-muted px-1 py-0.5 font-mono text-sm\"\u003e[Internet] ←→ [Router] ←→ [CSE-H53N] ←→ [Serial Device]\u003c\/code\u003e\u003c\/div\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eRemote access to serial devices from anywhere in the world.\u003c\/p\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eSerial Tunneling\u003c\/span\u003e\u003c\/h3\u003e\n\u003cdiv class=\"my-4 w-full max-w-full overflow-hidden\"\u003e\u003ccode class=\"rounded bg-muted px-1 py-0.5 font-mono text-sm\"\u003e[Serial Device A] ←→ [CSE-H53N A] ←→ [Network] ←→ [CSE-H53N B] ←→ [Serial Device B]\u003c\/code\u003e\u003c\/div\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eExtend serial connections over long distances via Ethernet.\u003c\/p\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eMultiple Monitoring\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"font-semibold\"\u003e                    ←→ [Monitor PC 1]\u003cbr\u003e[CSE-H53N] ←→ [Network] ←→ [Monitor PC 2]\u003cbr\u003e                    ←→ [Monitor PC 3]\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eMultiple clients simultaneously monitor one serial device (firmware v2.3A+).\u003c\/p\u003e\n\u003chr class=\"my-7 border-neutral-300 dark:border-neutral-700\"\u003e\n\u003ch2 class=\"mb-2 mt-4 break-words text-xl font-semibold\"\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eQ: What's the difference between the CSE-H53N and other serial converters?\u003c\/span\u003e\u003cbr\u003eA: The CSE-H53N offers industrial temperature range (-40°C to +85°C), full IPv6 support, SSL\/TLS security, multiple simultaneous connections, and advanced features like AT command mode and RFC 2217 support. It's designed for professional and industrial applications requiring reliability and advanced functionality.\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eQ: Does the CSE-H53N support IPv6?\u003c\/span\u003e\u003cbr\u003eA: Yes! The CSE-H53N has full IPv4\/IPv6 dual stack support with both stateless (SLAAC) and stateful (DHCPv6) address auto-configuration. It's fully ready for modern IPv6 networks.\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eQ: Can multiple computers access the serial device simultaneously?\u003c\/span\u003e\u003cbr\u003eA: Yes, with firmware version 2.3A or later, multiple TCP clients can connect to the CSE-H53N simultaneously. All connected clients receive the same serial data, perfect for distributed monitoring applications.\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eQ: What is AT Command mode?\u003c\/span\u003e\u003cbr\u003eA: AT Command mode is a patented Sollae Systems feature that allows you to control TCP\/IP connections dynamically via serial AT commands. You can establish connections, change IP addresses, modify ports, and configure network parameters without rebooting the device.\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eQ: How do I configure the CSE-H53N?\u003c\/span\u003e\u003cbr\u003eA: You have multiple options: (1) ezManager via Ethernet, (2) ezManager via serial port, (3) AT commands via serial terminal, or (4) Telnet. Choose the method that works best for your deployment.\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eQ: What is the default IP address?\u003c\/span\u003e\u003cbr\u003eA: The default IP address is 10.1.0.1 with subnet mask 255.0.0.0. The default local port is 1470, and the default serial settings are 19,200 bps, 8-N-1.\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eQ: Can I use this outdoors?\u003c\/span\u003e\u003cbr\u003eA: The CSE-H53N is rated for industrial temperatures (-40°C to +85°C) but is not waterproof. For outdoor use, install in a weatherproof enclosure (NEMA 4X or IP65 rated).\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eQ: Does it support SSL\/TLS encryption?\u003c\/span\u003e\u003cbr\u003eA: Yes, the CSE-H53N includes SSL\/TLS support for secure data transmission over the network. This protects your serial data from eavesdropping and tampering.\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eQ: What operating systems are supported?\u003c\/span\u003e\u003cbr\u003eA: The device works with any OS that supports TCP\/IP (Windows, Linux, macOS, Unix, etc.). The ezManager and ezVSP utilities are Windows-only, but you can configure via Telnet or AT commands from any platform.\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eQ: How do I update the firmware?\u003c\/span\u003e\u003cbr\u003eA: Use ezManager to upload new firmware. Enter ISP mode by pressing the function button for more than 3 seconds during power-on, then use ezManager's firmware update feature.\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eQ: What is RFC 2217 support?\u003c\/span\u003e\u003cbr\u003eA: RFC 2217 (Telnet COM Port Control Option) allows you to remotely change serial port parameters (baud rate, parity, data bits, etc.) over the network without physical access to the device.\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eQ: Can I use straight or crossover Ethernet cables?\u003c\/span\u003e\u003cbr\u003eA: Either! The CSE-H53N supports Auto MDI\/MDIX, which automatically detects and adapts to both cable types.\u003c\/p\u003e\n\u003ch2 class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\n\u003cspan class=\"italic\"\u003eTechnical Support \u0026amp; Resources\u003c\/span\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003cdiv\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/www.eztcp.com\/en\/products\/cse-h53n.php\" title=\"EZTCP CSE-H53N \/ Industrial RS232 Ethernet Device Server Web Page\" target=\"_blank\"\u003eCSE-H53N Industrial RS232 Ethernet Device Server Product Page\u003c\/a\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/www.eztcp.com\/en\/download\/utility.php\" title=\"EZTCP Utility Downloads\" target=\"_blank\"\u003eezTCP Utility Downloads\u003c\/a\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003ca href=\"https:\/\/www.eztcp.com\/en\/download\/pds_files\/ds_cseh53nen.pdf\" title=\"ezTCP CS-H53N Serial RS-232 to Ethernet Converter Datasheet\" rel=\"noopener\" target=\"_blank\"\u003e\u003cstrong\u003eCSE-H53N RS232 Ethernet Device Server Datasheet\u003c\/strong\u003e\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/www.eztcp.com\/en\/download\/pds_files\/cseh53nen.pdf\" title=\"EZTCP CSE-H53N Industrial RS232 Ethernet Device Server User Manual\" target=\"_blank\"\u003eCSE-H53N Industrial RS232 Ethernet Device Server User Manual\u003c\/a\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003ch3\u003e\n\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003eVideos\u003c\/h3\u003e\n\u003cp\u003eCSE-H53N Introductory video\u003c\/p\u003e\n\u003cp\u003e\u003ciframe width=\"560\" height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/BU2-Sg16M7I\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e","brand":"Sollae Systems","offers":[{"title":"Default Title","offer_id":14008787468372,"sku":"CSE-H53N-BO","price":83.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1641\/0911\/products\/cse-h53n-eztcp-industrial-rs232-ethernet-device-server-162303.jpg?v=1594221422"},{"product_id":"cse-h55n2-industrial-rs422-rs485-ethernet-device-server","title":"Sollae Systems ezTCP CSE-H55N2 Industrial RS-422\/RS-485 to Ethernet Converter","description":"\u003cp class=\"mb-2 mt-4 break-words text-xl font-semibold\"\u003eProfessional-Grade Multi-Drop Serial Networking with IPv4\/IPv6 Dual Stack Support: \u003cspan class=\"font-semibold\"\u003eTransform your RS-422\/RS-485 serial networks into IP-enabled infrastructure with industrial-grade reliability and advanced IPv4 and IPv6 support.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eThe Sollae Systems CSE-H55N2 is an industrial-grade RS-422\/RS-485 to Ethernet converter designed for demanding multi-drop serial networks. With support for both IPv4 and IPv6, extreme temperature range (-40°C to +85°C), and advanced features like SSL\/TLS security and multiple simultaneous connections, the CSE-H55N2 delivers enterprise-level performance for mission-critical industrial automation, SCADA, and building management systems.\u003c\/p\u003e\n\u003chr class=\"my-7 border-neutral-300 dark:border-neutral-700\"\u003e\n\u003ch2 class=\"mb-2 mt-4 break-words text-xl font-semibold\"\u003eWhy Choose the CSE-H55N2?\u003c\/h2\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e🔄\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eRS-422\/RS-485 Versatility\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eSupport for both RS-422 (full-duplex, point-to-point or multi-drop) and RS-485 (half-duplex, multi-drop up to 32 devices). One converter handles all your long-distance serial networking needs up to 4,000 feet.\u003c\/p\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e🌐\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eFuture-Proof IPv6 Support\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eFull IPv4\/IPv6 dual stack implementation with stateless and stateful (DHCPv6) address auto-configuration. Ready for modern networks and future IPv6 deployments with ICMPv6, TCPv6, and UDPv6 support.\u003c\/p\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e🏭\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eIndustrial-Grade Reliability\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eExtreme temperature range (-40°C to +85°C) and enhanced noise immunity make this converter perfect for harsh industrial environments. Upgraded from CSE-H55N with improved stability against electrical damage and noise on RS-422\/485 lines.\u003c\/p\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e🔒\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eEnterprise Security\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eBuilt-in SSL\/TLS encryption, IP\/MAC filtering, and password protection ensure your serial data remains secure across the network. Perfect for sensitive industrial control applications.\u003c\/p\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e🔄\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eMultiple Connection Support\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eMonitor and control from multiple locations simultaneously. Multiple clients can connect to a single CSE-H55N2 for distributed monitoring and control applications (firmware v2.3A or later).\u003c\/p\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e⚡\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eHigh-Speed Performance\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eRS-422\/RS-485 support up to 230.4 kbps ensures fast, reliable data transfer for even the most demanding serial applications. Long-distance capability up to 4,000 feet (1,200m).\u003c\/p\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e🛡️\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eEnhanced Protection\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eEmbedded 3.9kΩ biasing resistors and TVS (Transient Voltage Suppression) protection on all serial lines. Over-current, reverse voltage, and surge protection on power input.\u003c\/p\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e🎯\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eFlexible Configuration\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eConfigure via Ethernet (ezManager), serial port, AT commands, or Telnet. Choose the method that works best for your deployment scenario. Mobile apps available for iOS and Android.\u003c\/p\u003e\n\u003chr class=\"my-7 border-neutral-300 dark:border-neutral-700\"\u003e\n\u003ch2 class=\"mb-2 mt-4 break-words text-xl font-semibold\"\u003eCSE-H55N2 Technical Specifications\u003c\/h2\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003eSerial Interface\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003ePhysical Interface:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eType:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eRS-422 or RS-485 (software selectable)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eConnector:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e6-pin Terminal Block (3.5mm pitch)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eProtection:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eEmbedded 3.9kΩ biasing resistors and TVS on all lines\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eMaximum Distance:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e4,000 feet (1,200m)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eRS-422 Configuration:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eSignals:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eTX+, TX-, RX+, RX-, GND (2x)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eMode:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eFull-duplex\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eTopology:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003ePoint-to-point or multi-drop (1:N)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003ePin Assignment:\u003c\/span\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003ePin 1: TX+ (Transmit Data +)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003ePin 2: TX- (Transmit Data -)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003ePin 3: GND (Ground)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003ePin 4: RX+ (Receive Data +)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003ePin 5: RX- (Receive Data -)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003ePin 6: GND (Ground)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eRS-485 Configuration:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eSignals:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eTRX+, TRX-, GND (2x)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eMode:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eHalf-duplex\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eTopology:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eMulti-drop (up to 32 devices)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003ePin Assignment:\u003c\/span\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003ePin 1: TRX+ (Transmit\/Receive Data +)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003ePin 2: TRX- (Transmit\/Receive Data -)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003ePin 3: GND (Ground)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003ePin 6: GND (Ground)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eSerial Parameters:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eMaximum Baud Rate:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e230.4 kbps\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eSupported Baud Rates:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e300, 600, 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200, 230400 bps\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eData Bits:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e8 bits, 7 bits (with parity)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eParity:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eNone, Even, Odd, Mark, Space\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eStop Bits:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e1, 1.5, 2\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eFlow Control:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eNone, RTS\/CTS\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eNote:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eWhen Data Bits is set to 7, NONE parity cannot be used.\u003c\/p\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003eNetwork Interface\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eEthernet:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003ePort:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e1 x RJ-45 (10\/100 Mbps)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eSpeed:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e10Base-T or 100Base-TX (Auto-Sensing)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eCable Detection:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eAuto MDI\/MDIX (works with straight or crossover cables)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eConnector LEDs:\u003c\/span\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eGreen: Link status (On = connected, Blink = data activity)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eYellow: Speed indicator (Off = 10Mbps, On = 100Mbps)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eNetwork Protocols:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eIPv4:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eTCP, UDP, IP, ICMP, ARP, DHCP, PPPoE, DNS, DDNS, Telnet\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eIPv6:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eICMPv6, TCPv6, UDPv6, IPv6 fragmentation\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eIPv6 Configuration:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eStateless and Stateful (DHCPv6) auto-configuration\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eSecurity:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eSSL\/TLS (Secure Socket Layer)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eManagement:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eTelnet, HTTP (ezManager)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eAdvanced:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eTelnet COM Port Control Option (RFC 2217)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003eCommunication Modes\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eTCP Server (T2S):\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003ePassive connection mode\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eWaits for incoming TCP client connections\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eDefault local port: 1470\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eIdeal for centralized monitoring applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eTCP Client (COD):\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eActive connection mode\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eInitiates connection to remote TCP server\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eConfigurable peer IP address and port\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003ePerfect for data logging and cloud integration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eAT Command Mode (ATC):\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eControl connections dynamically via AT commands\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eBoth active and passive connections supported\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eAllows runtime configuration changes\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003ePatented Sollae Systems technology\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eUDP Mode (U2S):\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eConnectionless communication\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eBroadcast and multicast support\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eLow-latency data transfer\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eN:M topology (many-to-many communication)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003ePower Specifications\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eInput Voltage:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eDC 5V ±0.5V (±10%)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eCurrent Consumption:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e190mA typical\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003ePower Connector:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eDC jack (Outer: Ø3.5mm, Inner: Ø1.35mm)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eProtection:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eOver-current, reverse voltage, and surge protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003eEnvironmental Specifications\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eOperating Temperature:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e-40°C to +85°C (-40°F to 185°F)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eStorage Temperature:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e-40°C to +85°C\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eHumidity:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e5% to 95% RH, non-condensing\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eCertifications:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eKC, CE, FCC Class A, RoHS compliant\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003ePhysical Specifications\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eDimensions:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e94mm (W) x 57mm (L) x 24mm (H) (3.7\" x 2.24\" x 0.94\")\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eWeight:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eApproximately 64g (2.26 oz)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eMounting:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eDesktop (compact footprint)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eEnclosure:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eIndustrial-grade plastic housing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003eStatus Indicators (LEDs)\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eTop Panel LEDs:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003ePWR (Red):\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003ePower indicator (On = power supplied)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eSTS (Yellow):\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eStatus indicator\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eBlinks every second = Obtaining IP address\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eBlinks 4 times = No IP address (DHCP\/PPPoE failure)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eOn = TCP connection established\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eOff = ISP mode\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSimultaneous blink with LINK\/RXD\/TXD = Serial Configuration mode\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eLINK (Green):\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eEthernet link status (On = connected)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eRXD (Yellow):\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eEthernet receive activity (Blinks = receiving data)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eTXD (Green):\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eEthernet transmit activity (Blinks = transmitting data)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eFront Panel LEDs:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eSerial RXD (Yellow):\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eSerial receive activity\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eSerial TXD (Green):\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eSerial transmit activity\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr class=\"my-7 border-neutral-300 dark:border-neutral-700\"\u003e\n\u003ch2 class=\"mb-2 mt-4 break-words text-xl font-semibold\"\u003eReal-World Applications\u003c\/h2\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e🏭\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eIndustrial Automation \u0026amp; SCADA\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eConnect PLCs, RTUs, and industrial controllers to SCADA systems\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eMulti-drop RS-485 networks for sensor arrays and I\/O modules\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eRemote monitoring and control of manufacturing equipment\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eBuilding automation and energy management\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eFactory floor data collection and distribution\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eProcess control and monitoring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e⚡\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eEnergy \u0026amp; Utilities\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eSmart grid monitoring and control\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSubstation automation (IEC 61850)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eRemote meter reading (AMR\/AMI) via RS-485 networks\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003ePower distribution management\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eEnvironmental monitoring stations\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSolar and wind farm monitoring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e🏗️\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eBuilding Management Systems (BMS)\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eHVAC control systems\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eLighting control networks\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eAccess control and security systems\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eFire alarm panels\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eEnergy management systems\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eMulti-building campus networks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e🚂\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eTransportation \u0026amp; Infrastructure\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eRailway signaling and control systems\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eTraffic management and ITS applications\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eAirport ground support equipment\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eParking management systems\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eToll collection systems\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eFleet management\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e📡\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eTelecommunications\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eSerial console access to network equipment\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eRemote management of telecom infrastructure\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eBase station monitoring and control\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eNetwork operations center (NOC) equipment\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eMulti-drop equipment monitoring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e🔬\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eLaboratory \u0026amp; Research\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eNetwork analytical instruments via RS-485\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eAutomated testing equipment\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eQuality control systems\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eResearch data acquisition\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eEnvironmental monitoring networks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e🏥\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eHealthcare \u0026amp; Medical\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eLaboratory automation systems\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eMedical equipment networking\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eBuilding management in healthcare facilities\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eEnvironmental monitoring (temperature, humidity)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eEquipment status monitoring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e💧\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eWater \u0026amp; Wastewater Treatment\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eSCADA systems for water treatment plants\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eRemote pump station monitoring\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eFlow meter data collection\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eChemical dosing control\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eMulti-site monitoring networks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAs well as industrial environments, the CSE-H55N2 is ideal for serial RS-422 \/ RS-485 to Ethernet control of diverse applications such as:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.eztcp.com\/en\/applications\/manage-solar\" title=\"Serial RS-422 \/ RS-485 to Ethernet control of Solar Energy Management Systems\" target=\"_blank\"\u003eSolar Energy Management Systems\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.eztcp.com\/en\/applications\/rs485-substitution\" title=\"Converting RS422\/RS485 Systems to TCP\/IP Networks\" target=\"_blank\"\u003eConverting RS422\/RS485 Systems to TCP\/IP Networks\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.eztcp.com\/en\/applications\/pantilt-control\" title=\"Remote Controlling Pan Tilt Cameras with RS422\/RS485 to Ethernet Adapter\" target=\"_blank\"\u003eRemote Controlling Pan Tilt Cameras\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr class=\"my-7 border-neutral-300 dark:border-neutral-700\"\u003e\n\u003ch2 class=\"mb-2 mt-4 break-words text-xl font-semibold\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e✓\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eCSE-H55N2 RS-422\/RS-485 to Ethernet Converter\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e(1 unit)\u003cbr\u003e✓\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eQuick Start Guide\u003c\/span\u003e\u003cbr\u003e✓\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eSoftware available for download:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eezManager (Configuration utility for Windows)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eezVSP (Virtual Serial Port driver for Windows)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eezTerm (TCP\/IP communication test tool)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eUser manual (PDF)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eDatasheet (PDF)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cem class=\"italic\"\u003eAll software is available for download from the Sollae Systems ezTCP website. See the link under the \u003cstrong\u003eTechnical Support \u0026amp; Resources\u003c\/strong\u003e section below.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eOptional Accessories\u003c\/h3\u003e\n\u003cp\u003e\u003ca rel=\"noopener\" title=\"AC\/DC WALL MOUNT ADAPTER 5V 5W W\/ 2.1MM X 5.5MM DC OUTPUT CONNECTOR\" href=\"https:\/\/envistiamall.com\/products\/ac-dc-wall-mount-adapter-5v-5w-dc-power-connector\" target=\"_blank\"\u003e+5V AC\/DC Wall Mount Power Supply\u003c\/a\u003e\u003c\/p\u003e\n\u003chr class=\"my-7 border-neutral-300 dark:border-neutral-700\"\u003e\n\u003ch2 class=\"mb-2 mt-4 break-words text-xl font-semibold\"\u003eQuick Setup Guide\u003c\/h2\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eStep 1: Physical Connections\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cstrong\u003e\u003cspan class=\"font-semibold\"\u003eFor RS-422 (Full-Duplex):\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eConnect TX+, TX-, RX+, RX- to terminal block pins 1, 2, 4, 5\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eConnect GND to pins 3 and 6\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eConfigure as RS-422 in ezManager\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cstrong\u003e\u003cspan class=\"font-semibold\"\u003eFor RS-485 (Half-Duplex):\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eConnect TRX+, TRX- to terminal block pins 1, 2\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eConnect GND to pins 3 and 6\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eConfigure as RS-485 in ezManager\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eEnable termination resistors on first and last devices only\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cstrong\u003e\u003cspan class=\"font-semibold\"\u003eNetwork \u0026amp; Power:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eConnect Ethernet cable to your network (straight or crossover - auto-detected)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eConnect 5V DC power adapter\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003ePWR LED will illuminate when powered on\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eStep 2: Network Configuration\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eDefault Settings:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eIP Address:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e10.1.0.1\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eSubnet Mask:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e255.0.0.0\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eLocal Port:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e1470\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eCommunication Mode:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eTCP Server\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eSerial Type:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eRS-485\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eBaud Rate:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e19,200 bps\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eData Format:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e8-N-1 (8 data bits, No parity, 1 stop bit)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cstrong\u003e\u003cspan class=\"font-semibold\"\u003eConfiguration Methods:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cstrong\u003e\u003cspan class=\"font-semibold\"\u003eOption A - ezManager via Ethernet (Recommended):\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003col class=\"ml-8 list-outside list-decimal\"\u003e\n\u003cli class=\"py-0.5\"\u003eDownload and run ezManager (no installation required)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eClick [MAC Address Search] or [IP Address Search] to discover CSE-H55N2\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSelect the device\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eConfigure network, serial, and communication parameters\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eClick [Write] to save settings\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eDevice will reboot automatically\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cstrong\u003e\u003cspan class=\"font-semibold\"\u003eOption B - Serial Configuration:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003col class=\"ml-8 list-outside list-decimal\"\u003e\n\u003cli class=\"py-0.5\"\u003ePress function button for 1-3 seconds to enter Serial Configuration mode\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eAll LEDs (STS, LINK, RXD, TXD) blink simultaneously\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eOpen ezManager, select [Serial] tab\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSelect COM port and click [Open]\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eClick [Read] to load current settings\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eModify parameters as needed\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eClick [Write] to save\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cstrong\u003e\u003cspan class=\"font-semibold\"\u003eOption C - AT Commands:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003col class=\"ml-8 list-outside list-decimal\"\u003e\n\u003cli class=\"py-0.5\"\u003eSet communication mode to \"AT Command\" via ezManager\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eConnect via serial terminal (matching baud rate, 8-N-1)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eUse AT commands to configure parameters\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSave with AT+PWP command\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eStep 3: Test Communication\u003c\/span\u003e\u003c\/h3\u003e\n\u003col class=\"ml-8 list-outside list-decimal\"\u003e\n\u003cli class=\"py-0.5\"\u003eUse ezManager's [Simple Test] feature\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eConfigure TCP connection (IP address and port)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eOpen serial port with matching parameters\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSend test data in both directions to verify operation\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eTotal setup time: 5-10 minutes\u003c\/span\u003e\u003c\/p\u003e\n\u003chr class=\"my-7 border-neutral-300 dark:border-neutral-700\"\u003e\n\u003ch2 class=\"mb-2 mt-4 break-words text-xl font-semibold\"\u003eAdvanced Features \u0026amp; Capabilities\u003c\/h2\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eRS-422\/RS-485 Flexibility\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eRS-422 Mode (Full-Duplex):\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003ePoint-to-Point (1:1):\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eDirect connection between two devices\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eMulti-Drop (1:N):\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eOne master transmitter, multiple receivers\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eMaximum Distance:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e4,000 feet (1,200m)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eAdvantages:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eFull-duplex, simultaneous bidirectional communication\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eUse Cases:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eLong-distance point-to-point links, distributed monitoring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eRS-485 Mode (Half-Duplex):\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eMulti-Drop Network:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eUp to 32 devices on one bus\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eMaximum Distance:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e4,000 feet (1,200m)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eTopology:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eDaisy-chain (linear bus)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eAdvantages:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eMultiple devices on single cable pair, cost-effective\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eUse Cases:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eModbus RTU, Profibus, BACnet MS\/TP, building automation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eBuilt-in Protection:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003e3.9kΩ Biasing Resistors:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eEmbedded on all serial lines for idle state stability\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eTVS Protection:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eTransient Voltage Suppression protects against electrical spikes\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eEnhanced Noise Immunity:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eUpgraded design from CSE-H55N for improved stability\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eIPv6 Dual Stack Implementation\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eThe CSE-H55N2 is fully IPv6-ready with comprehensive support:\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eIPv6 Features:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eFull IPv4\/IPv6 dual stack operation\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eStateless address auto-configuration (SLAAC)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eStateful address configuration (DHCPv6)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eIPv6 fragmentation support\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eICMPv6, TCPv6, UDPv6 protocols\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSeamless IPv4\/IPv6 interoperability\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eWhy IPv6 Matters:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eFuture-proof your infrastructure\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eLarger address space eliminates NAT complexity\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eImproved security with IPsec integration\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eBetter support for IoT devices\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSimplified network configuration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eMultiple Connection Support\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eSimultaneous Monitoring (Firmware v2.3A+):\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eMultiple TCP clients can connect to one CSE-H55N2 simultaneously\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003ePerfect for distributed monitoring applications\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eEach client receives the same serial data\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eIdeal for redundant monitoring systems\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eNo additional hardware required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eUse Cases:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eMultiple operators monitoring the same equipment\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eRedundant data logging systems\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eDistributed SCADA architectures\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eMulti-site monitoring applications\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eBackup monitoring stations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eSSL\/TLS Security\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eSecure Socket Layer Protection:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eEncrypt serial data over the network\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eProtect sensitive information in transit\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eIndustry-standard SSL\/TLS protocols\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eCertificate-based authentication\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003ePrevents eavesdropping and tampering\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eSecurity Features:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eIP address filtering (whitelist\/blacklist)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eMAC address filtering\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003ePassword-protected configuration\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSecure firmware updates\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eAccess control lists\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003ePacket Fragmentation Control\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eSeparator Settings:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eDefine custom packet delimiters\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eControl when data is transmitted over network\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eOptimize for different protocols and applications\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eReduce network overhead\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eImprove application-level parsing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eData Frame Interval:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eConfigure timeout for packet assembly\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eBalance real-time performance vs. network efficiency\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eAdjustable from 0ms (immediate) to custom values\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eOptimize for your specific application\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eTelnet COM Port Control (RFC 2217)\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eRemote Serial Port Control:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eChange serial parameters remotely over network\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eAdjust baud rate, parity, data bits, stop bits\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eControl flow control settings\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eMonitor serial port status\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eNo physical access required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eBenefits:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eRemote troubleshooting and diagnostics\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eDynamic serial parameter adjustment\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eCentralized serial port management\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eReduced site visits and maintenance costs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eDynamic DNS (DDNS) Support\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eAlways Accessible:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eAutomatic DNS updates when IP address changes\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eUse hostname instead of IP address\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003ePerfect for dynamic IP environments\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSupports major DDNS providers\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSimplified remote access\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003ePPPoE Support\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eDirect Internet Connection:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eConnect directly to DSL\/cable modems\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eNo router required for simple deployments\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eAutomatic authentication and connection\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eIdeal for remote installations\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eReduced hardware costs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eAT Command Mode\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003ePatented Dynamic Control:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eChange connection parameters at runtime\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eEstablish\/terminate connections via serial commands\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eNo device reboot required\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003ePerfect for applications requiring dynamic connectivity\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eUnique Sollae Systems technology\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eAT Command Capabilities:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eConfigure IP addresses and ports\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eEstablish TCP connections\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eControl DHCP and PPPoE\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSet DNS servers\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eModify timeout values\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSave settings to flash memory\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr class=\"my-7 border-neutral-300 dark:border-neutral-700\"\u003e\n\u003ch2 class=\"mb-2 mt-4 break-words text-xl font-semibold\"\u003eSoftware Suite\u003c\/h2\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eezManager - Configuration Utility\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eComprehensive Management Tool for Windows:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eFeatures:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eNo installation required (portable application)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eAutomatic device discovery via MAC or IP address\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eIntuitive graphical interface\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eReal-time status monitoring\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eFirmware update management\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eConfiguration backup and restore\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSimple test utility included\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eBatch configuration for multiple devices\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eConfiguration Methods:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eVia Ethernet (LAN)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eVia Serial port\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eRemote configuration via Telnet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eezVSP - Virtual Serial Port Driver\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eWindows Virtual COM Port Driver:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eFeatures:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eCreates virtual COM ports on Windows PC\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eLegacy applications work without modification\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSupports multiple virtual ports\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eAutomatic reconnection on network interruption\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eCompatible with Windows 7\/8\/10\/11\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eNo application changes required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eHow It Works:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eThe CSE-H55N2 appears as a local COM port on your Windows PC. Your existing serial software communicates with the virtual port, and ezVSP handles all network communication transparently.\u003c\/p\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eezTerm - Communication Test Tool\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eSimple TCP\/IP Testing:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eFeatures:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eQuick TCP\/IP communication testing\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eBoth TCP and UDP support\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eServer and client modes\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eHex and ASCII data display\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eData logging capabilities\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003ePerfect for troubleshooting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eSmartphone Applications\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eMobile Configuration:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eezManager app available for iOS and Android\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eConfigure devices from your smartphone or tablet\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eMonitor status remotely\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003ePerfect for field installations\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eFree download from app stores\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr class=\"my-7 border-neutral-300 dark:border-neutral-700\"\u003e\n\u003ch2 class=\"mb-2 mt-4 break-words text-xl font-semibold\"\u003eRS-485 Network Configuration Guide\u003c\/h2\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eTermination Resistors\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eRS-485 networks require 120Ω termination resistors at both ends of the bus:\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eEnable termination\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eon the first and last devices only\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eDisable termination\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eon all middle devices\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eImproper termination causes communication errors and reflections\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eUse quality 120Ω resistors rated for your application\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eBiasing Resistors\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eThe CSE-H55N2 includes embedded 3.9kΩ biasing resistors:\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003ePurpose:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eMaintain idle state voltage levels on the bus\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eBenefit:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003ePrevents false triggering and improves noise immunity\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eBuilt-in:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eNo external biasing resistors required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eWiring Best Practices\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eCable Selection:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eUse\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003etwisted pair cable\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e(Cat5e or better, or dedicated RS-485 cable)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eShielded cable\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003erecommended in electrically noisy environments\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eCharacteristic impedance:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e120Ω for proper termination\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eTopology:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eUse\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003edaisy-chain topology\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e(linear bus)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eAvoid\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003estar topology\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e(creates reflections)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eKeep\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003estubs\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eshorter than 1 meter\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eMaximum bus length:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e4,000 feet (1,200m)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eGrounding:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eConnect\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eGND\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eat both ends (pins 3 and 6)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eMaintain\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eproper grounding\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eto prevent ground loops\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eUse\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003esingle-point ground\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003ewhen possible\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eShield grounding:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eGround shield at one end only to prevent ground loops\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eMulti-Drop Addressing\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eFor RS-485 networks with multiple devices:\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eEach device needs a\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eunique address\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e(configured in serial device)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eCSE-H55N2 acts as\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003etransparent bridge\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e(no addressing required)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eUse\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eModbus RTU\u003c\/span\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eProfibus\u003c\/span\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eBACnet MS\/TP\u003c\/span\u003e, or other multi-drop protocols\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eConfigure\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eappropriate timeout\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003evalues for polling applications\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eMaximum devices:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e32 per bus (standard RS-485 limit)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eSignal Quality\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eDifferential Signaling:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eRS-485 uses differential signaling (Data+ and Data-)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eCommon-mode noise rejection:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eExcellent immunity to electrical interference\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eVoltage levels:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eTypically ±200mV to ±6V differential\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eNoise Immunity:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eTVS protection:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eBuilt-in transient voltage suppression\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eBiasing resistors:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eEmbedded 3.9kΩ resistors for idle state stability\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eShielded cable:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eUse in high-EMI environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr class=\"my-7 border-neutral-300 dark:border-neutral-700\"\u003e\n\u003ch2 class=\"mb-2 mt-4 break-words text-xl font-semibold\"\u003eRS-422 Network Configuration Guide\u003c\/h2\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003e1:1 Configuration (Point-to-Point)\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eStandard RS-422 Connection:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eConnect TX+ to RX+, TX- to RX- on both ends\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eFull-duplex communication\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eMaximum distance: 4,000 feet (1,200m)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eNo termination resistors required for short distances\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eUse 120Ω termination for long distances or high speeds\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003e1:N Configuration (Multi-Drop)\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eOne Transmitter, Multiple Receivers:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eOne CSE-H55N2 transmits (TX+, TX-)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eMultiple devices receive (RX+, RX-)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eUp to 10 receivers typical (depends on driver capability)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eTermination resistors at both ends of receive line\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eIdeal for distributed monitoring applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eSignal Ground, Biasing, and Termination\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eGround Connection:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eConnect GND (pins 3 and 6) at both ends\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003ePrevents ground potential differences\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eImproves signal integrity\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eBiasing Resistors:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eEmbedded 3.9kΩ biasing resistors included\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eMaintains idle state voltage levels\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eNo external biasing required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eTermination Resistors:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e120Ω resistors at both ends of long cables\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003ePrevents signal reflections\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eRequired for high-speed or long-distance applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr class=\"my-7 border-neutral-300 dark:border-neutral-700\"\u003e\n\u003ch2 class=\"mb-2 mt-4 break-words text-xl font-semibold\"\u003eOperation Modes\u003c\/h2\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eNormal Mode\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eStandard Operation:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eFor normal data communication\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eFour communication modes available (TCP Server, TCP Client, AT Command, UDP)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eConfiguration via ezManager or Telnet\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eReal-time status monitoring\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eDefault operating mode\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eSerial Configuration Mode\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eSerial Port Configuration:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eConfigure via RS-422\/485 port\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eUse ezManager Serial tab\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eNo network connection required\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003ePerfect for initial setup or network troubleshooting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eHow to Enter:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003ePress function button for 1-3 seconds\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eAll LEDs (STS, LINK, RXD, TXD) blink simultaneously\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eConnect via serial port with matching parameters\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eISP Mode (In-System Programming)\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eFirmware Updates:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eFor upgrading firmware\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eBypass security settings (password recovery)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eDirect firmware upload via ezManager\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eFactory reset capability\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eEmergency recovery mode\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eHow to Enter:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003ePress function button for more than 3 seconds during power-on\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSTS LED turns off\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eUpload firmware via ezManager\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr class=\"my-7 border-neutral-300 dark:border-neutral-700\"\u003e\n\u003ch2 class=\"mb-2 mt-4 break-words text-xl font-semibold\"\u003eNetwork Topology Examples\u003c\/h2\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003e1:1 Direct Connection\u003c\/span\u003e\u003c\/h3\u003e\n\u003cdiv class=\"my-4 w-full max-w-full overflow-hidden\"\u003e\u003ccode class=\"rounded bg-muted px-1 py-0.5 font-mono text-sm\"\u003e[PC] ←→ [CSE-H55N2] ←→ [RS-422\/485 Device]\u003c\/code\u003e\u003c\/div\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eSimple point-to-point connection for testing or isolated systems.\u003c\/p\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eLAN Integration\u003c\/span\u003e\u003c\/h3\u003e\n\u003cdiv class=\"my-4 w-full max-w-full overflow-hidden\"\u003e\n\u003cdiv class=\"code-block group relative my-1 rounded-[18px] overflow-hidden bg-muted\"\u003e\n\u003cdiv class=\"flex items-center justify-between px-3 py-2 bg-[#f5f5f7]\"\u003e\n\u003cdiv class=\"font-mono text-[11px] capitalize text-muted-foreground\"\u003e[Network Switch] ←→ [CSE-H55N2] ←→ [RS-485 Bus] ←→ [Device 1] [Device 2] ... [Device 32]\u003cbr\u003e                 ←→ [PC 1]\u003cbr\u003e                 ←→ [PC 2]\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eMultiple PCs access RS-485 multi-drop network over local network.\u003c\/p\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eInternet Access via Router\u003c\/span\u003e\u003c\/h3\u003e\n\u003cdiv class=\"my-4 w-full max-w-full overflow-hidden\"\u003e\u003ccode class=\"rounded bg-muted px-1 py-0.5 font-mono text-sm\"\u003e[Internet] ←→ [Router] ←→ [CSE-H55N2] ←→ [RS-485 Network]\u003c\/code\u003e\u003c\/div\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eRemote access to serial devices from anywhere in the world.\u003c\/p\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eSerial Tunneling\u003c\/span\u003e\u003c\/h3\u003e\n\u003cdiv class=\"my-4 w-full max-w-full overflow-hidden\"\u003e\u003ccode class=\"rounded bg-muted px-1 py-0.5 font-mono text-sm\"\u003e[RS-485 Device A] ←→ [CSE-H55N2 A] ←→ [Network] ←→ [CSE-H55N2 B] ←→ [RS-485 Device B]\u003c\/code\u003e\u003c\/div\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eExtend serial connections over long distances via Ethernet.\u003c\/p\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eMultiple Monitoring\u003c\/span\u003e\u003c\/h3\u003e\n\u003cdiv class=\"my-4 w-full max-w-full overflow-hidden\"\u003e\n\u003cdiv class=\"code-block group relative my-1 rounded-[18px] overflow-hidden bg-muted\"\u003e\n\u003cdiv class=\"flex items-center justify-between px-3 py-2 bg-[#f5f5f7]\"\u003e\n\u003cdiv class=\"font-mono text-[11px] capitalize text-muted-foreground\"\u003e                    ←→ [Monitor PC 1]\u003cbr\u003e[CSE-H55N2] ←→ [Network] ←→ [Monitor PC 2]\u003cbr\u003e                    ←→ [Monitor PC 3]\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eMultiple clients simultaneously monitor one RS-485 network (firmware v2.3A+).\u003c\/p\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eMulti-Drop RS-485 Network\u003c\/span\u003e\u003c\/h3\u003e\n\u003cdiv class=\"my-4 w-full max-w-full overflow-hidden\"\u003e\n\u003cdiv class=\"code-block group relative my-1 rounded-[18px] overflow-hidden bg-muted\"\u003e\n\u003cdiv class=\"flex items-center justify-between px-3 py-2 bg-[#f5f5f7]\"\u003e\n\u003cdiv class=\"font-mono text-[11px] capitalize text-muted-foreground\"\u003e[CSE-H55N2] ←→ [RS-485 Bus] ←→ [Sensor 1] [Sensor 2] ... [Sensor 32]\u003cbr\u003e     ↑              (Termination)                    (Termination)\u003cbr\u003e     |\u003cbr\u003e[Ethernet Network]\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eClassic RS-485 multi-drop topology with up to 32 devices.\u003c\/p\u003e\n\u003chr class=\"my-7 border-neutral-300 dark:border-neutral-700\"\u003e\n\u003ch2 class=\"mb-2 mt-4 break-words text-xl font-semibold\"\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eQ: What's the difference between the CSE-H55N2 and the CSE-H53N?\u003c\/span\u003e\u003cbr\u003eA: The CSE-H55N2 supports RS-422\/RS-485 (long-distance, multi-drop capable), while the CSE-H53N supports RS-232 only (short-distance, point-to-point). The CSE-H55N2 is ideal for industrial multi-drop networks up to 4,000 feet, while the CSE-H53N is for simple RS-232 device networking.\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eQ: What's the difference between the CSE-H55N2 and the original CSE-H55N?\u003c\/span\u003e\u003cbr\u003eA: The CSE-H55N2 is an upgraded version with improved stability against noise and electrical damage on RS-422\/485 lines. It features enhanced protection with embedded TVS and better noise immunity. The software functionality remains the same.\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eQ: Can I use this for Modbus RTU networks?\u003c\/span\u003e\u003cbr\u003eA: Yes! The CSE-H55N2 is perfect for Modbus RTU over RS-485. It acts as a transparent bridge, allowing your Modbus master to communicate with up to 32 Modbus slave devices over Ethernet. The converter doesn't interpret Modbus protocol—it simply passes data transparently.\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eQ: How many devices can I connect on an RS-485 network?\u003c\/span\u003e\u003cbr\u003eA: Standard RS-485 supports up to 32 devices (unit loads) per bus. The CSE-H55N2 counts as one device. For larger networks, use RS-485 repeaters to extend beyond 32 devices.\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eQ: Do I need termination resistors?\u003c\/span\u003e\u003cbr\u003eA: Yes, RS-485 networks require 120Ω termination resistors at both ends of the bus (first and last devices). The CSE-H55N2 includes embedded biasing resistors but you must add external termination resistors at the bus ends.\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eQ: What's the maximum cable distance?\u003c\/span\u003e\u003cbr\u003eA: RS-422\/RS-485 supports up to 4,000 feet (1,200m) at lower baud rates. At maximum baud rate (230.4 kbps), distance may be limited to 100-300 feet depending on cable quality and environmental noise.\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eQ: Does the CSE-H55N2 support IPv6?\u003c\/span\u003e\u003cbr\u003eA: Yes! The CSE-H55N2 has full IPv4\/IPv6 dual stack support with both stateless (SLAAC) and stateful (DHCPv6) address auto-configuration. It's fully ready for modern IPv6 networks.\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eQ: Can multiple computers access the serial network simultaneously?\u003c\/span\u003e\u003cbr\u003eA: Yes, with firmware version 2.3A or later, multiple TCP clients can connect to the CSE-H55N2 simultaneously. All connected clients receive the same serial data, perfect for distributed monitoring applications.\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eQ: What is AT Command mode?\u003c\/span\u003e\u003cbr\u003eA: AT Command mode is a patented Sollae Systems feature that allows you to control TCP\/IP connections dynamically via serial AT commands. You can establish connections, change IP addresses, modify ports, and configure network parameters without rebooting the device.\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eQ: How do I configure the CSE-H55N2?\u003c\/span\u003e\u003cbr\u003eA: You have multiple options: (1) ezManager via Ethernet, (2) ezManager via serial port, (3) AT commands via serial terminal, or (4) Telnet. Choose the method that works best for your deployment.\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eQ: What is the default IP address?\u003c\/span\u003e\u003cbr\u003eA: The default IP address is 10.1.0.1 with subnet mask 255.0.0.0. The default local port is 1470, serial type is RS-485, and the default serial settings are 19,200 bps, 8-N-1.\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eQ: Can I use this outdoors?\u003c\/span\u003e\u003cbr\u003eA: The CSE-H55N2 is rated for industrial temperatures (-40°C to +85°C) but is not waterproof. For outdoor use, install in a weatherproof enclosure (NEMA 4X or IP65 rated).\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eQ: Does it support SSL\/TLS encryption?\u003c\/span\u003e\u003cbr\u003eA: Yes, the CSE-H55N2 includes SSL\/TLS support for secure data transmission over the network. This protects your serial data from eavesdropping and tampering.\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eQ: What operating systems are supported?\u003c\/span\u003e\u003cbr\u003eA: The device works with any OS that supports TCP\/IP (Windows, Linux, macOS, Unix, etc.). The ezManager and ezVSP utilities are Windows-only, but you can configure via Telnet or AT commands from any platform.\u003c\/p\u003e\n\u003ch2 class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"italic\"\u003eTechnical Support \u0026amp; Resources\u003c\/span\u003e\u003c\/h2\u003e\n\u003cdiv\u003e\u003cstrong\u003e\u003ca title=\"EZTCP CSE-H55N2 \/ Industrial RS422\/RS485 Ethernet Device Server Web Page\" href=\"https:\/\/www.eztcp.com\/en\/products\/cse-h55n2.php\" target=\"_blank\"\u003eCSE-H55N2 Industrial \u003cspan\u003eRS422\/RS485 \u003c\/span\u003eEthernet Device Server Product Page\u003c\/a\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cstrong\u003e\u003ca title=\"EZTCP Utility Downloads\" href=\"https:\/\/www.eztcp.com\/en\/download\/utility.php\" target=\"_blank\"\u003eEZTCP Utility Downloads\u003c\/a\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003ca rel=\"noopener\" title=\"EZTCP CSE-H55N2 Industrial RS422\/RS485 Serial to Ethernet Device Server Datasheet\" href=\"\/https:\/\/www.eztcp.com\/en\/download\/pds_files\/ds_cseh55n2en.pdf\" target=\"_blank\"\u003e\u003cstrong\u003eCSE-H55N2 Industrial RS422\/RS485 Ethernet Device Server Datasheet\u003c\/strong\u003e\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cstrong\u003e\u003ca title=\"EZTCP CSE-H55N2 Industrial RS422\/RS485 Ethernet Device Server User Manual\" href=\"https:\/\/www.eztcp.com\/en\/download\/pds_files\/cseh55n2en.pdf\" target=\"_blank\"\u003eCSE-H55N2 Industrial RS422\/RS485 Ethernet Device Server User Manual\u003c\/a\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003ch3\u003e\n\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003eVideos\u003c\/h3\u003e\n\u003cp\u003eSollae Systems ezTCP CSE-H55N2 Introductory video\u003c\/p\u003e\n\u003cp\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/qtR4_T-2-Zc\" height=\"315\" width=\"560\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e","brand":"Sollae Systems","offers":[{"title":"Default Title","offer_id":14015809486932,"sku":"CSE-H55N2-BO","price":114.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1641\/0911\/products\/cse-h55n2-eztcp-industrial-rs422rs485-ethernet-device-server-353555.jpg?v=1594221422"},{"product_id":"cse-m73a-eztcp-rs232-rs422-rs485-serial-to-ethernet-module","title":"CSE-M73A Serial RS232 \/ RS422 \/ RS485 to Ethernet Network Module","description":"\u003cp\u003eThe ezTCP CSE-M73A from Sollae Systems is an embedded serial to Ethernet module. Embedded with an optimized TCP\/IP stack, this module is equipped with an Ethernet RJ45 connector and a serial port interfaced with RS232, RS422, and RS485. The CSE-M73A provides conversion functions to remotely control and manage serial devices over Ethernet.\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003eThe CSE-M73A is especially suitable for \u003ca href=\"https:\/\/www.eztcp.com\/en\/applications\/multi-conn\" title=\"Multi Monitoring with the ezTCP CSE-M73A Serial Ethernet Module\" target=\"_blank\"\u003eMulti Monitoring\u003c\/a\u003e, \u003ca href=\"https:\/\/www.eztcp.com\/en\/applications\/manage-solar\" title=\"Solar Energy Management Systems with the ezTCP CSE-M73A Serial Ethernet Module\" target=\"_blank\"\u003eSolar Energy Management Systems\u003c\/a\u003e, etc.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e1 x RS232\/RS422\/RS485\u003c\/li\u003e\n\u003cli\u003e10\/100Mbps Ethernet\u003c\/li\u003e\n\u003cli\u003eRJ45 connector embedded\u003c\/li\u003e\n\u003cli\u003eCompact module type (64.4mm x 40mm x 17mm)\u003c\/li\u003e\n\u003cli\u003eMulti-Monitoring (maximum 8 channels)\u003c\/li\u003e\n\u003cli\u003eSSL (Secure Sockets Layer)\u003c\/li\u003e\n\u003cli\u003eSeparator settings for packet fragmentation\u003c\/li\u003e\n\u003cli\u003eFlexible configuration and network communication by 'AT Commands' (patent)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSerial Interface\n\u003cul\u003e\n\u003cli\u003eRS232 - RXD, TXD, CTS, RTS, GND\u003cbr\u003e3.3V level with 5V tolerant input - RXD, TXD, RTS, CTS, GND\u003cbr\u003eRS422 - TX+, TX-, RX+, RX-, GND\u003cbr\u003eRS485 - TRX+, TRX- , GND\u003c\/li\u003e\n\u003cli\u003eConnector: 1 X 6 2.54mm pitch pin header\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eSerial Port Property\n\u003cul\u003e\n\u003cli\u003eBaud Rate: 300 bps ~ 230,400 bps\u003c\/li\u003e\n\u003cli\u003eData Bits: 5, 6, 7, 8 bits\u003c\/li\u003e\n\u003cli\u003eParity: None, Even, Odd, Mark, Space\u003c\/li\u003e\n\u003cli\u003eStop Bit: 1, 1.5, 2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eNetwork Interface\n\u003cul\u003e\n\u003cli\u003e10Base-T\/100Base-TX Ethernet (RJ45)\u003c\/li\u003e\n\u003cli\u003eEthernet Speed Auto Sense\u003c\/li\u003e\n\u003cli\u003e1:1 or Cross-over Cable Auto Sense\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003eSoftware Functions\u003c\/li\u003e\n\u003cul\u003e\n\u003cli\u003eProtocols\n\u003cul\u003e\n\u003cli\u003eTCP, UDP, IP, ICMP, ARP, Ethernet, TELNET\u003cbr\u003eTFTP, DHCP, PPPoE, DNS, DDNS\u003cbr\u003eTelnet COM Port Control Option (RFC 2217)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eSecurity\n\u003cul\u003e\n\u003cli\u003eSSL(Secure Socket Layer)\u003c\/li\u003e\n\u003cli\u003eSSH (Secure Shell)\u003c\/li\u003e\n\u003cli\u003eIP \u0026amp; MAC Filtering - Restrict Host or Network\u003c\/li\u003e\n\u003cli\u003ePassword for Configuring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eCommunication Mode\n\u003cul\u003e\n\u003cli\u003eTCP Server (T2S)\u003c\/li\u003e\n\u003cli\u003eTCP Client (COD)\u003c\/li\u003e\n\u003cli\u003eTCP Server\/Client with AT Command (ATC) - Patent\u003c\/li\u003e\n\u003cli\u003eUDP Mode (U2S)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eAdditional Functions\n\u003cul\u003e\n\u003cli\u003eMulti-monitoring(Max. 8 TCP connections simultaneously)\u003c\/li\u003e\n\u003cli\u003eRemote Debug Function\u003c\/li\u003e\n\u003cli\u003eTCP Server\/Client Mode\u003c\/li\u003e\n\u003cli\u003eSending MAC address Option\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003eIndicators (LEDs)\u003c\/li\u003e\n\u003cul\u003e\n\u003cli\u003ePower: Red\u003c\/li\u003e\n\u003cli\u003eLAN Link\/LAN RXD: Green\u003c\/li\u003e\n\u003cli\u003eStatus\/LAN TXD: Yellow\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003eManagement:\n\u003cul\u003e\n\u003cli\u003eezManager: Configuration and Monitoring Tool through Network and Serial\u003c\/li\u003e\n\u003cli\u003eTelnet: Telnet Login\u003c\/li\u003e\n\u003cli\u003eAT Command: Configuring in ATC mode - Patent\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eSupplementary Software\n\u003cul\u003e\n\u003cli\u003eezManager: Configuration Tool for Windows\u003c\/li\u003e\n\u003cli\u003eezVSP: Serial to Network Virtual Driver for Windows\u003c\/li\u003e\n\u003cli\u003eezTERM: Simple TCP\/IP Communication Test Tool\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eDimensions\n\u003cul\u003e\n\u003cli\u003eSize: 64.4mm x 40mm x 17mm (2.54in x 1.57in x 0.67in)\u003c\/li\u003e\n\u003cli\u003eWeight: 19 Grams (0.7 Ounces)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eOperating Environment\n\u003cul\u003e\n\u003cli\u003eInput Voltage: 5VDC\u003c\/li\u003e\n\u003cli\u003eCurrent Consumption: 200mA typical\u003c\/li\u003e\n\u003cli\u003eOperating Temperature: 0C ~ +55C\u003c\/li\u003e\n\u003cli\u003eStorage Temperature: -45C ~ +85C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e* The above information is subject to change. Envistia Mall and Sollae Systems are not responsible for any changes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e Package includes:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"padding-left: 30px;\"\u003e1X CSE-M73A ezTCP Serial Ethernet Module\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDelivery of evaluation quantities is\u003cspan\u003e \u003c\/span\u003estock\u003cspan\u003e \u003c\/span\u003eto 2 weeks, if the item is out of stock, please contact us for availability.\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDocumentation \u0026amp; Resources:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.eztcp.com\/en\/products\/cse-m73a\" title=\"CSE-M73A \/ Serial Ethernet Module\" target=\"_blank\"\u003e\u003cstrong\u003eEZTCP CSE-M73A Serial Ethernet Module Product Page\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.eztcp.com\/en\/download\/utility.php\" target=\"_blank\"\u003e\u003cstrong\u003eEZTCP Utility Downloads\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eVideos:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eCSE-M73A ezTCP Serial Ethernet Module Product Video\u003c\/p\u003e\n\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/z5Mf3QQQwC8\" height=\"315\" width=\"560\" allowfullscreen=\"\" allow=\"accelerometer; autoplay; encrypted-media; gyroscope; picture-in-picture\" frameborder=\"0\"\u003e\u003c\/iframe\u003e","brand":"Sollae Systems","offers":[{"title":"Default Title","offer_id":40496620175555,"sku":"CSE-M73A-BO","price":59.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1641\/0911\/products\/cse-m73a-eztcp-serial-rs232-rs422-rs485-to-ethernet-module-573744.jpg?v=1629778992"},{"product_id":"serial-rs232-rs422-rs485-to-ethernet-converter-slan","title":"SystemBase sLAN\/All Serial to Ethernet Converter (RS-232\/422\/485)","description":"\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eConnect any serial device to your Ethernet network - RS-232, RS-422, or RS-485 - with one versatile, industrial-grade converter.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eThe SystemBase sLAN\/All is the professional's choice for serial-to-Ethernet conversion. With support for all three major serial standards, ultra-compact design, and industrial-grade reliability, this converter handles any serial networking challenge you can throw at it.\u003c\/p\u003e\n\u003chr class=\"my-7 border-neutral-300 dark:border-neutral-700\"\u003e\n\u003ch2 class=\"mb-2 mt-4 break-words text-xl font-semibold\"\u003eWhy the sLAN\/All is Your Best Investment\u003c\/h2\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e🔄\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eUltimate Versatility\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eOne device supports RS-232, RS-422, AND RS-485. No need to stock multiple converter types. The sLAN\/All adapts to any serial interface with simple configuration.\u003c\/p\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e📦\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eUltra-Compact Design\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eAt just 54mm x 72mm x 28.4mm and weighing only 100g, the sLAN\/All is one of the smallest serial-to-Ethernet converters available. Perfect for space-constrained installations.\u003c\/p\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e💪\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eIndustrial-Grade Durability\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eBuilt to withstand extreme environments with an operating temperature range of -40°C to 85°C. Designed for continuous 24\/7\/365 operation in the harshest industrial settings.\u003c\/p\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e🚀\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eHigh-Speed Performance\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eSupport for baud rates up to 921.6 kbps ensures fast, reliable data transfer. RS-422\/485 modes support long-distance communication up to 4,000 feet (1,200m).\u003c\/p\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e🛡️\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eMaximum Protection\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eESD protection: Contact ±2-4kV, Air ±2-8kV\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSurge and EFT protection per KS C standards\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eBuilt-in termination resistors for RS-422\/485\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e🎯\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003ePlug-and-Play Simplicity\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eWeb-based configuration, automatic device discovery with SGConfig utility, and virtual COM port software make setup effortless—even for complex multi-drop RS-485 networks.\u003c\/p\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e⚡\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eLow Power Consumption\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eMaximum 1.25W power consumption with 5V DC input. Energy-efficient design for always-on applications.\u003c\/p\u003e\n\u003chr class=\"my-7 border-neutral-300 dark:border-neutral-700\"\u003e\n\u003ch2 class=\"mb-2 mt-4 break-words text-xl font-semibold\"\u003esLAN\/All Technical Specifications\u003c\/h2\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003eSerial Interface Options\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eRS-232 Mode:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003ePort:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e1 x RS-232 (DB9 Male connector)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eSignals:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eTXD, RXD, RTS, CTS, DTR, DSR, DCD, RI, GND\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eMaximum Distance:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e50 feet (15m)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\u003cspan class=\"font-semibold\"\u003eFull duplex communication\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eRS-422 Mode:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003ePort:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e1 x RS-422 (DB9 Male connector)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eSignals:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eTXD+, TXD-, RXD+, RXD-, GND\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eMaximum Distance:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e4,000 feet (1,200m)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\u003cspan class=\"font-semibold\"\u003eFull duplex communication\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eMulti-drop mode:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eMaster\/Slave configuration supported\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eRS-485 Mode:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003ePort:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e1 x RS-485 (DB9 Male connector)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eSignals:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eTRXD+, TRXD-, GND\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eMaximum Distance:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e4,000 feet (1,200m)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\u003cspan class=\"font-semibold\"\u003eHalf duplex communication\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eMulti-drop support:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eUp to 32 devices per network\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eBuilt-in termination resistors (120Ω)\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e- Enable\/Disable via software\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003eCommon Serial Parameters (All Modes)\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eMaximum Baud Rate:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e921.6 kbps\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eSupported Baud Rates:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e150, 300, 600, 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200, 230400, 460800, 921600 bps\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eData Bits:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e8 (only)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eStop Bits:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e1, 2\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eParity:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eNone, Even, Odd\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eFlow Control:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eNone, RTS\/CTS (RS-232 mode only)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003eNetwork Interface\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eEthernet Port:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e1 x 10\/100 Mbps Auto-MDIX (RJ-45)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eNetwork Protocols:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eTCP, UDP, ICMP, DHCP, HTTP, IPv4\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eOperating Modes:\u003c\/span\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eCOM Redirector\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e- Virtual COM port functionality\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eTCP Server\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e- Listen for incoming connections\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eTCP Client\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e- Connect to remote host\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eUDP Server\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e- Receive UDP packets\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eUDP Client\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e- Send UDP packets\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eIP Configuration:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eStatic IP or DHCP\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eDefault IP Address:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e192.168.0.223\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eConnection Management:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eMultiple simultaneous connections\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eSecurity:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003ePassword-protected configuration (Default ID: slan, PW: 99999999)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003ePower Specifications\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eInput Voltage:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e5V DC, 1A or higher\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003ePower Consumption:\u003c\/span\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eMaximum: 1.25W\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eOperating: 1W\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eStandby: 0.5W\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003ePower Connector:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eDC Jack (External: Φ3.5mm, Internal: Φ1.35mm)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eIncluded:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e5V DC power adapter\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003eProtection \u0026amp; Reliability\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eESD Protection:\u003c\/span\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eContact: Min ±2kV, Max ±4kV\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eAir: Min ±2kV, Max ±8kV\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eStandards Compliance:\u003c\/span\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eKS C 9610-4-2 (ESD)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eKS C 9610-4-4 (EFT)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eKS C 9610-4-5 (Surge)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eMTBF:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e1,448,154 hours (165+ years)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003eConfiguration \u0026amp; Management\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eSetup Methods:\u003c\/span\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eWeb-based configuration interface (HTTP)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSGConfig utility (Windows 7 or above)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eTestView testing software\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eSoftware Included:\u003c\/span\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eCOM Port Redirector (Virtual COM Port driver)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSGConfig (Configuration utility)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eTestView (Testing and diagnostics)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eStatus Indicators:\u003c\/span\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eRDY (Yellow) - Blinks during operation\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eTXD (Green) - Blinks when transmitting serial data\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eRXD (Red) - Blinks when receiving serial data\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eLAN Port LEDs - Yellow (Link\/Activity), Green (100Mbps)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eReset Button:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003ePress \u0026lt; 3 seconds to reboot, \u0026gt; 3 seconds for factory reset\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eFirmware Updates:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eRemote updates via web interface\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003eEnvironmental Specifications\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eOperating Temperature:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e-40°C to 85°C (-40°F to 185°F) - Industrial grade\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eStorage Temperature:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e-40°C to 85°C\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eHumidity:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e5% to 90% RH, non-condensing\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eCertifications:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eCE, FCC Class A (Industrial use), RoHS compliant\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003ePhysical Specifications\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eDimensions:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e54mm (W) x 72mm (L) x 28.4mm (H) (2.13\" x 2.83\" x 1.12\")\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eWeight:\u003c\/span\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eProduct only: 100g (3.5 oz)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eGross weight (with packaging): 322g (11.4 oz)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eMounting:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eDesktop (compact footprint)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eEnclosure:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eIndustrial-grade plastic housing\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eConnectors:\u003c\/span\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e1 x DB9 Male (RS-232\/422\/485)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e1 x RJ-45 (Ethernet)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e1 x DC Jack (Power input)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e1 x Reset button\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr class=\"my-7 border-neutral-300 dark:border-neutral-700\"\u003e\n\u003ch2 class=\"mb-2 mt-4 break-words text-xl font-semibold\"\u003eReal-World Applications\u003c\/h2\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e🏭\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eIndustrial Automation \u0026amp; SCADA\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eConnect PLCs, RTUs, and industrial controllers to SCADA systems\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eMulti-drop RS-485 networks for sensor arrays and I\/O modules\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eRemote monitoring and control of manufacturing equipment\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eBuilding automation and energy management systems\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eFactory floor data collection and distribution\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e🏥\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eHealthcare \u0026amp; Medical Equipment\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eNetwork legacy diagnostic equipment and patient monitors\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eLaboratory automation and LIMS integration\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eMedical imaging device connectivity\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eMeasuring instruments and gas detectors\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eHospital infrastructure management\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e🚂\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eTransportation \u0026amp; Infrastructure\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eRailway signaling and control systems\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eTraffic management and ITS (Intelligent Transportation Systems)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eAirport ground support equipment\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eParking management and access control\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eLogistics and conveyor belt systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e⚡\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eEnergy \u0026amp; Utilities\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eSmart grid monitoring and control\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003ePower management devices\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eRemote meter reading (AMR\/AMI)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eWater and pollution detectors\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eEnvironmental monitoring stations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e📡\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eTelecommunications\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eSerial console access to network equipment\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eRemote management of telecom infrastructure\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eBase station monitoring and control\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eNetwork operations center (NOC) equipment\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e🏪\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eRetail \u0026amp; Point of Sale\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eCard readers and barcode scanners\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003ePOS devices and kiosks\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSerial printers and ATM machines\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eCredit card terminals\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eInventory management systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e🔬\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eLaboratory \u0026amp; Research\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eNetwork analytical instruments and data loggers\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eControllers on inspection equipment\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eAutomated testing equipment\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eQuality control systems\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eResearch data acquisition\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e🏗️\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eSecurity \u0026amp; Access Control\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eBiometric sensors and alarm devices\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eCard readers and access control panels\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eCCTV camera control (PTZ)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eIntrusion detection systems\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSecurity devices\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e🎮\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eConsumer Electronics\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eGame console connectivity\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eHome appliance networking\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003ePower management devices\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eData collection and distribution devices\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr class=\"my-7 border-neutral-300 dark:border-neutral-700\"\u003e\n\u003ch2 class=\"mb-2 mt-4 break-words text-xl font-semibold\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e✓\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003esLAN\/All V2.0 Serial to Ethernet Converter\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e(1 unit)\u003cbr\u003e✓\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003e5V DC Power Adapter\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e(1A or higher)\u003cbr\u003e✓\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eLAN Cable\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e(Ethernet cable)\u003cbr\u003e✓\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eEject Pin\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e(for DB9 connector)\u003cbr\u003e✓\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eQuick Start Guide\u003c\/span\u003e\u003cbr\u003e\u003cspan class=\"font-semibold\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cem class=\"italic\"\u003eAll software is available for download from the SystemBase website. See the link under the \u003cstrong\u003eTechnical Support \u0026amp; Resources\u003c\/strong\u003e section below.\u003c\/em\u003e\u003c\/p\u003e\n\u003chr class=\"my-7 border-neutral-300 dark:border-neutral-700\"\u003e\n\u003ch2 class=\"mb-2 mt-4 break-words text-xl font-semibold\"\u003eQuick Setup Guide\u003c\/h2\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eStep 1: Choose Your Serial Interface\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eThe sLAN\/All uses a single DB9 Male connector that supports all three serial modes. Configure the interface type via the web interface or SGConfig utility.\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cstrong\u003e\u003cspan class=\"font-semibold\"\u003eFor RS-232:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eConnect your RS-232 device to the DB9 port\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eConfigure Interface setting to \"RS-232\" in web interface\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003ePins: TXD(3), RXD(2), RTS(7), CTS(8), DTR(4), DSR(6), DCD(1), RI(9), GND(5)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cstrong\u003e\u003cspan class=\"font-semibold\"\u003eFor RS-422:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eConnect your RS-422 device to the DB9 port\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eConfigure Interface setting to \"RS-422\" in web interface\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eConfigure RS-422 Multi-Drop Mode (Master or Slave)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003ePins: TXD+(2), TXD-(1), RXD+(3), RXD-(7), GND(5)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cstrong\u003e\u003cspan class=\"font-semibold\"\u003eFor RS-485:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eConnect your RS-485 device to the DB9 port\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eConfigure Interface setting to \"RS-485\" in web interface\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eEnable\/disable termination resistor as needed\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003ePins: TRXD+(2), TRXD-(1), GND(5)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eStep 2: Power \u0026amp; Network Connection\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eConnect the included 5V DC power adapter to the DC jack\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eConnect Ethernet cable to your network (supports both straight and crossover cables)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eRDY LED will blink when device is operating\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eLAN Port LEDs indicate network connection status\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eStep 3: Network Configuration\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cstrong\u003e\u003cspan class=\"font-semibold\"\u003eOption A - Use Default IP Address:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eConfigure your PC to access 192.168.0.x network\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eOpen web browser and navigate to\u003cspan\u003e \u003c\/span\u003e\n\u003cdiv\u003ehttp:\/\/192.168.0.223\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eLogin with default credentials (ID: slan, Password: 99999999)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cstrong\u003e\u003cspan class=\"font-semibold\"\u003eOption B - Use SGConfig Utility:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eRun SGConfig on Windows PC\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eClick [Search] to discover sLAN\/All devices on network\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSelect device and click [Configure]\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eStep 4: Configure Settings\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eNetwork Settings:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eSet Static IP or DHCP, configure IP address, subnet mask, gateway\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eSerial Settings:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eConfigure operation mode, baud rate, data bits, stop bits, parity, flow control\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eInterface:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eSelect RS-232, RS-422, or RS-485\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eClick [Submit] to save changes\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eReboot device to apply settings\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eStep 5: Test \u0026amp; Deploy\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eUse TestView software to verify communication\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eInstall COM Port Redirector if using virtual COM port mode\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eMonitor status via web interface or SGConfig\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eTotal setup time: 5-10 minutes\u003c\/span\u003e\u003c\/p\u003e\n\u003chr class=\"my-7 border-neutral-300 dark:border-neutral-700\"\u003e\n\u003ch2 class=\"mb-2 mt-4 break-words text-xl font-semibold\"\u003eAdvanced Features \u0026amp; Capabilities\u003c\/h2\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eFlexible Serial Interface Selection\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eThe sLAN\/All uses a single DB9 connector that supports all three serial standards:\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eSoftware configuration\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e- Switch between RS-232, RS-422, and RS-485 via web interface\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eNo hardware jumpers\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e- All configuration is done through software\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003ePin mapping\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e- Automatic pin assignment based on selected interface\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eHot-swappable\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003ebetween modes (after reboot)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eRS-485 Multi-Drop Networking\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003ePerfect for industrial applications requiring multiple devices on one network:\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eSupport for up to 32 devices per RS-485 bus\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSoftware-configurable termination resistors (120Ω)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eHalf-duplex communication\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eTransparent data transmission\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eCompatible with Modbus RTU, Profibus, BACnet MS\/TP, and other protocols\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eRS-422 Multi-Drop Mode\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eUnique RS-422 multi-drop capability:\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eMaster mode:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eFor primary controller\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eSlave mode:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eFor secondary devices\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003ePoint-to-point:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eSet both devices to Master for 1:1 connections\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eFull-duplex communication\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eLong-distance support up to 4,000 feet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eVirtual COM Port Technology\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eThe included COM Port Redirector creates virtual COM ports on Windows systems:\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eLegacy applications work without modification\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSupports multiple virtual ports simultaneously\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eAutomatic reconnection on network interruption\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eCompatible with Windows 7\/8\/10\/11\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eMultiple Operating Modes\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cstrong\u003e\u003cspan class=\"font-semibold\"\u003eCOM Redirector Mode:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eCreates virtual COM port on Windows PC\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSerial port settings follow virtual COM port configuration\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003ePerfect for legacy software compatibility\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cstrong\u003e\u003cspan class=\"font-semibold\"\u003eTCP Server Mode:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eDevice listens for incoming connections on configured port (default: 4001)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eMultiple clients can connect simultaneously\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eTransparent data transfer between socket and serial port\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eIdeal for centralized monitoring applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cstrong\u003e\u003cspan class=\"font-semibold\"\u003eTCP Client Mode:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eDevice initiates connection to remote server\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eConfigure target IP address and port\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eAutomatic reconnection on network interruption\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003ePerfect for data logging and cloud integration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cstrong\u003e\u003cspan class=\"font-semibold\"\u003eUDP Server Mode:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eReceives UDP packets on configured port\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eForwards data to serial port\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSends serial data as UDP packets to client\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eLow-latency communication\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cstrong\u003e\u003cspan class=\"font-semibold\"\u003eUDP Client Mode:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eSends serial data as UDP packets to configured server\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eConfigure target IP address and port\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eIdeal for broadcast\/multicast applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eIntelligent Data Handling\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cstrong\u003e\u003cspan class=\"font-semibold\"\u003eLatency Time Configuration:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eSet to 0 for real-time operation (immediate forwarding)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSet to non-zero to buffer data and reduce network traffic\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eConfigurable in milliseconds\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eBalances real-time performance vs. network efficiency\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cstrong\u003e\u003cspan class=\"font-semibold\"\u003eTCP Alive Check:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eMonitors network connection health at configured intervals\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eAutomatically terminates\/resets failed connections\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eConfigurable from 0-65,535 seconds\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSet to 0 to disable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cstrong\u003e\u003cspan class=\"font-semibold\"\u003eTCP No-Delay Option:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eDisabled:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eBuffers TCP data before processing (better for high-speed\/packet-based)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eEnabled:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eProcesses TCP data immediately (minimizes delay)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eOptimizes for different application requirements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eNetwork Discovery \u0026amp; Management\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eAutomatic device discovery\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003evia SGConfig utility\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eWeb-based configuration\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eaccessible from any browser\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003ePassword protection\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003efor secure access\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eFactory reset\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003evia reset button (press \u0026gt; 3 seconds)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eRemote firmware updates\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003evia web interface\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eReal-time status monitoring\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003ewith LED indicators\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eAuto-MDIX Support\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eAutomatically detects straight or crossover Ethernet cables\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eNo need for specific cable types\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSimplifies installation and reduces errors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr class=\"my-7 border-neutral-300 dark:border-neutral-700\"\u003e\n\u003ch2 class=\"mb-2 mt-4 break-words text-xl font-semibold\"\u003eSoftware Suite\u003c\/h2\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eCOM Port Redirector (Virtual COM Port Driver)\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eCreates virtual COM ports on Windows systems, allowing legacy serial applications to communicate over the network without modification.\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cstrong\u003e\u003cspan class=\"font-semibold\"\u003eFeatures:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eMultiple virtual COM ports per device\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eAutomatic reconnection\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eFlow control support\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eCompatible with Windows 7 and above\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eHow it works:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eWhen Operation Mode is set to \"COM Redirector,\" the sLAN\/All serial port appears as a local COM port on your Windows PC. Your existing serial software works without any changes.\u003c\/p\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eSGConfig Configuration Utility\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eComprehensive Windows application for device management:\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cstrong\u003e\u003cspan class=\"font-semibold\"\u003eFeatures:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eAutomatic device discovery on network\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eIntuitive GUI for all configuration parameters\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eBatch configuration for multiple devices\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eReal-time monitoring and diagnostics\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eConfiguration backup and restore\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eCompatible with Windows 7 and above\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eTestView Testing Software\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eProfessional testing and diagnostic tool:\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cstrong\u003e\u003cspan class=\"font-semibold\"\u003eFeatures:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eSerial port communication testing\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eNetwork connectivity verification\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eData transmission monitoring\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eProtocol analysis\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003ePerformance benchmarking\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eTroubleshooting wizards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr class=\"my-7 border-neutral-300 dark:border-neutral-700\"\u003e\n\u003ch2 class=\"mb-2 mt-4 break-words text-xl font-semibold\"\u003eRS-485 Configuration Guide\u003c\/h2\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eTermination Resistors\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eRS-485 networks require 120Ω termination resistors at both ends of the bus:\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eEnable termination\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eon the first and last devices only via web interface\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eDisable termination\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eon all middle devices\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSoftware-configurable (no hardware jumpers required)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eImproper termination causes communication errors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eWiring Best Practices\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eUse\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003etwisted pair cable\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e(Cat5e or better, or dedicated RS-485 cable)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eKeep\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003etotal bus length under 4,000 feet\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e(1,200m)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eUse\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003edaisy-chain topology\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e(not star)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eAvoid\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003estubs\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003elonger than 1 meter\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eMaintain\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eproper grounding\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eto prevent ground loops\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eUse\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eshielded cable\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003ein electrically noisy environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003ePin Assignment for RS-485\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003ePin 1:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eTRXD- (Data-)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003ePin 2:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eTRXD+ (Data+)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003ePin 5:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eGND (Ground)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eMulti-Drop Addressing\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eFor RS-485 networks with multiple devices:\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eEach device needs a\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eunique address\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e(configured in serial device)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003esLAN\/All V2.0 acts as\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003etransparent bridge\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e(no addressing required)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eUse\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eModbus RTU\u003c\/span\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eProfibus\u003c\/span\u003e, or other multi-drop protocols\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eConfigure\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eappropriate timeout\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003evalues for polling applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr class=\"my-7 border-neutral-300 dark:border-neutral-700\"\u003e\n\u003ch2 class=\"mb-2 mt-4 break-words text-xl font-semibold\"\u003eRS-422 Multi-Drop Configuration\u003c\/h2\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eMaster\/Slave Mode\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eThe sLAN\/All V2.0 supports RS-422 multi-drop configurations:\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eMaster Mode:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eSet for the primary controller device\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eTransmits data to multiple slave devices\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eSlave Mode:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eSet for secondary devices\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eReceives data from master\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003ePoint-to-Point (1:1):\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eSet both connected devices to Master mode\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eStandard RS-422 full-duplex communication\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003ePin Assignment for RS-422\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003ePin 1:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eTXD- (Transmit-)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003ePin 2:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eTXD+ (Transmit+)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003ePin 3:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eRXD+ (Receive+)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003ePin 7:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eRXD- (Receive-)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003ePin 5:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eGND (Ground)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr class=\"my-7 border-neutral-300 dark:border-neutral-700\"\u003e\n\u003ch2 class=\"mb-2 mt-4 break-words text-xl font-semibold\"\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eQ: What's the difference between the sLAN\/All and the CS-LAN?\u003c\/span\u003e\u003cbr\u003eA: The sLAN\/All supports RS-232, RS-422, AND RS-485. The CS-LAN is RS-232 only. The sLAN\/All is also more compact (54x72x28.4mm vs 85x65x25mm) and has a higher MTBF rating.\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eQ: Does the sLAN\/All support Power over Ethernet (PoE)?\u003c\/span\u003e\u003cbr\u003eA: No, the V2.0 model requires external 5V DC power via the included adapter. For PoE capability, consider the \u003ca href=\"https:\/\/envistiamall.com\/products\/poe-serial-rs232-rs422-rs485-to-ethernet-converter-slan-all\" target=\"_blank\" title=\"SystemBase sLAN\/All-POE POE-powered serial to Ethernet converter\" rel=\"noopener\"\u003esLAN\/All PoE\u003c\/a\u003e model (sold separately).\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eQ: What voltage does the sLAN\/All require?\u003c\/span\u003e\u003cbr\u003eA: The device requires 5V DC, 1A or higher. A compatible power adapter is included in the box.\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eQ: How do I switch between RS-232, RS-422, and RS-485 modes?\u003c\/span\u003e\u003cbr\u003eA: All configuration is done through software via the web interface or SGConfig utility. Simply select the desired interface type in the Serial Settings page and reboot the device. No hardware jumpers required.\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eQ: What's the maximum number of devices on an RS-485 network?\u003c\/span\u003e\u003cbr\u003eA: The sLAN\/All supports up to 32 devices per RS-485 bus. For larger networks, use RS-485 repeaters.\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eQ: Can I use this outdoors?\u003c\/span\u003e\u003cbr\u003eA: The sLAN\/All is rated for industrial temperatures (-40°C to 85°C) but is not waterproof. For outdoor use, install in a weatherproof enclosure (NEMA 4X or IP65 rated).\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eQ: What operating systems are supported?\u003c\/span\u003e\u003cbr\u003eA: The device works with any OS that supports TCP\/IP (Windows, Linux, macOS, Unix, etc.). The COM Port Redirector and SGConfig utilities require Windows 7 or above, but the web interface works in any modern browser.\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eQ: How do I reset the device to factory defaults?\u003c\/span\u003e\u003cbr\u003eA: Press and hold the RST button on the rear panel for more than 3 seconds. The device will reset to factory default settings (IP: 192.168.0.223, ID: slan, Password: 99999999).\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eQ: Can I use straight or crossover Ethernet cables?\u003c\/span\u003e\u003cbr\u003eA: Either! The sLAN\/All supports Auto-MDIX, which automatically detects and adapts to both cable types.\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eQ: What is the default IP address?\u003c\/span\u003e\u003cbr\u003eA: The default IP address is 192.168.0.223 with subnet mask 255.255.255.0 and gateway 192.168.0.254.\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eQ: How do I update the firmware?\u003c\/span\u003e\u003cbr\u003eA: Firmware updates can be performed remotely via the web interface. No physical access required.\u003c\/p\u003e\n\u003chr class=\"my-7 border-neutral-300 dark:border-neutral-700\"\u003e\n\u003ch2 class=\"mb-2 mt-4 break-words text-xl font-semibold\"\u003eTechnical Support \u0026amp; Resources\u003c\/h2\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\u003ca rel=\"noopener\" title=\"SystemBase sLAN\/All User Manual (PDF)\" href=\"https:\/\/envistia.com\/documents\/sLAN_all_UserManual_Eng_v2.0.pdf\" target=\"_blank\"\u003eDownload the sLAN\/All User Manual (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003ca href=\"https:\/\/www.sysbas.com\/en\/downloads\/cs-lan\/\" title=\"SystemBase CS-LAN Software and Utilities Downloads\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca rel=\"noopener\" title=\"SystemBase sLAN\/All Software and Utilities Downloads\" href=\"https:\/\/www.sysbas.com\/en\/downloads\/slan-all\/\" target=\"_blank\"\u003eDownload Configuration Software and Utilities (SystemBase Website)\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eNeed help? Contact our technical support team at\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"mailto:support@envistiamall.com\" class=\"cursor-pointer break-words text-[#2964AA] hover:opacity-80 dark:text-[#7AB7FF]\"\u003esupport@envistiamall.com\u003c\/a\u003e\u003c\/p\u003e","brand":"SystemBase","offers":[{"title":"Default Title","offer_id":42073675694329,"sku":"sLAN-All","price":215.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1641\/0911\/files\/systembase-slanall-serial-to-ethernet-converter-rs-232422485-2231370.jpg?v=1772363708"},{"product_id":"poe-serial-rs232-rs422-rs485-to-ethernet-converter-slan-all","title":"SystemBase sLAN\/all-PoE Serial to Ethernet Converter (RS-232\/422\/485) with Power over Ethernet","description":"\u003ch2 class=\"mb-2 mt-4 break-words text-xl font-semibold\"\u003eUltra-Compact Serial Networking Solution with PoE\u003c\/h2\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eConnect any serial device to your Ethernet network - RS-232, RS-422, or RS-485 - with one versatile, industrial-grade converter. Powered directly from your network switch via PoE (Power over Ethernet).\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eThe SystemBase sLAN\/all-PoE is the professional's choice for serial-to-Ethernet conversion with Power over Ethernet capability. With support for all three major serial standards, IEEE 802.3af PoE, ultra-compact design, and industrial-grade reliability, this converter handles any serial networking challenge while eliminating the need for separate power adapters.\u003c\/p\u003e\n\u003chr class=\"my-7 border-neutral-300 dark:border-neutral-700\"\u003e\n\u003ch2 class=\"mb-2 mt-4 break-words text-xl font-semibold\"\u003eWhy the sLAN\/all-PoE is Your Best Investment\u003c\/h2\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e⚡\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003ePower over Ethernet (PoE)\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eEliminate separate power adapters entirely. The sLAN\/all-PoE draws power directly from your PoE-enabled network switch via IEEE 802.3af standard. One cable provides both data and power—perfect for remote installations and clean cable management.\u003c\/p\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e🔄\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eUltimate Versatility\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eOne device supports RS-232, RS-422, AND RS-485. No need to stock multiple converter types—the sLAN\/all-PoE adapts to any serial interface with simple software configuration.\u003c\/p\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e📦\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eUltra-Compact Design\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eAt just 54.5mm x 102.5mm x 24.5mm and weighing only 79g, the sLAN\/all-PoE is one of the smallest PoE-enabled serial-to-Ethernet converters available. Perfect for space-constrained installations.\u003c\/p\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e💪\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eIndustrial-Grade Durability\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eBuilt to withstand extreme environments with an operating temperature range of -40°C to 85°C (non-PoE) or -20°C to 70°C (PoE mode). Designed for continuous 24\/7\/365 operation in demanding industrial settings.\u003c\/p\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e🚀\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eHigh-Speed Performance\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eSupport for baud rates up to 921.6 kbps ensures fast, reliable data transfer. RS-422\/485 modes support long-distance communication up to 4,000 feet (1,200m).\u003c\/p\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e🛡️\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eMaximum Protection\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e±15kV IEC ESD protection on all serial lines\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSurge and EFT protection per KS C standards\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eBuilt-in termination resistors for RS-422\/485\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e🎯\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003ePlug-and-Play Simplicity\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eWeb-based configuration, automatic device discovery with SGConfig utility, and virtual COM port software make setup effortless—even for complex multi-drop RS-485 networks.\u003c\/p\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e🔌\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eDual Power Options\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eUse PoE for clean installations or fall back to Micro-USB power (5V DC) when PoE isn't available. Maximum flexibility for any deployment scenario.\u003c\/p\u003e\n\u003chr class=\"my-7 border-neutral-300 dark:border-neutral-700\"\u003e\n\u003ch2 class=\"mb-2 mt-4 break-words text-xl font-semibold\"\u003esLAN\/All POE Technical Specifications\u003c\/h2\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003eSerial Interface Options\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cstrong\u003e\u003cspan class=\"font-semibold\"\u003eRS-232 Mode:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003ePort:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e1 x RS-232 (DB9 Male connector)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eSignals:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eTXD, RXD, RTS, CTS, DTR, DSR, DCD, RI, GND\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eMaximum Distance:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e50 feet (15m)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\u003cspan class=\"font-semibold\"\u003eFull duplex communication\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cstrong\u003e\u003cspan class=\"font-semibold\"\u003eRS-422 Mode:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003ePort:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e1 x RS-422 (DB9 Male connector)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eSignals:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eTXD+, TXD-, RXD+, RXD-, GND\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eMaximum Distance:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e4,000 feet (1,200m)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\u003cspan class=\"font-semibold\"\u003eFull duplex communication\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eMulti-drop mode:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eMaster\/Slave configuration supported\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cstrong\u003e\u003cspan class=\"font-semibold\"\u003eRS-485 Mode:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003ePort:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e1 x RS-485 (DB9 Male connector)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eSignals:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eTRXD+, TRXD-, GND\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eMaximum Distance:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e4,000 feet (1,200m)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\u003cspan class=\"font-semibold\"\u003eHalf duplex communication\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eMulti-drop support:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eUp to 32 devices per network\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eBuilt-in termination resistors (120Ω)\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e- Enable\/Disable via software\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003eCommon Serial Parameters (All Modes)\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eMaximum Baud Rate:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e921.6 kbps\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eSupported Baud Rates:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e150, 300, 600, 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200, 230400, 460800, 921600 bps\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eData Bits:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e5, 6, 7, 8\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eStop Bits:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e1, 2\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eParity:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eNone, Even, Odd\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eFlow Control:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eNone, RTS\/CTS (RS-232 mode only), XON\/XOFF\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003eNetwork Interface\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eEthernet Port:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e1 x 10\/100 Mbps Auto-MDIX (RJ-45 with PoE PD function)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eNetwork Protocols:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eTCP, UDP, ICMP, DHCP, HTTP, IPv4\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eOperating Modes:\u003c\/span\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eCOM Redirector\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e- Virtual COM port functionality\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eTCP Server\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e- Listen for incoming connections\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eTCP Client\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e- Connect to remote host\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eUDP Server\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e- Receive UDP packets\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eUDP Client\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e- Send UDP packets\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eIP Configuration:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eStatic IP or DHCP (Dynamic IP)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eDefault IP Address:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e192.168.0.223\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eConnection Management:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eMultiple simultaneous connections\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eSecurity:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003ePassword-protected configuration (Default ID: slan, PW: 99999999)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003ePower Specifications\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cstrong\u003e\u003cspan class=\"font-semibold\"\u003ePower over Ethernet (PoE) - Primary:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eStandard:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eIEEE 802.3af (PoE PD - Powered Device)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eInput Voltage:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e48V DC from PoE switch\/injector\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003ePower Consumption:\u003c\/span\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eOperating \u0026amp; Standby: 0.6W\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eOperating Temperature (PoE mode):\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e-20°C to 70°C (-4°F to 158°F)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cstrong\u003e\u003cspan class=\"font-semibold\"\u003eMicro-USB Power - Backup\/Alternative:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eInput Voltage:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e5V DC via Micro-USB Type B connector\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003ePower Consumption:\u003c\/span\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eMaximum: 1.2W\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eOperating: 1.0W\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eStandby: 0.9W\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eOperating Temperature (USB mode):\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e-40°C to 85°C (-40°F to 185°F)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eNote:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eDevice can be powered by either PoE or Micro-USB (not simultaneously required)\u003c\/p\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003eProtection \u0026amp; Reliability\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eESD Protection:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e±15kV IEC standard on all serial lines\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eStandards Compliance:\u003c\/span\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eKS C 9610-4-2 (ESD)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eKS C 9610-4-4 (EFT)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eKS C 9610-4-5 (Surge)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003eConfiguration \u0026amp; Management\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eSetup Methods:\u003c\/span\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eWeb-based configuration interface (HTTP)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSGConfig utility (Windows 7 or above)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eTestView testing software\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eSoftware Included:\u003c\/span\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eCOM Port Redirector (Virtual COM Port driver)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSGConfig (Configuration utility)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eTestView (Testing and diagnostics)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eStatus Indicators:\u003c\/span\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eRDY (Yellow) - Blinks during operation\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eTXD (Green) - Blinks when transmitting serial data\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eRXD (Red) - Blinks when receiving serial data\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eLAN Port LEDs - Yellow (100Mbps Link\/Activity), Green (10Mbps Link\/Activity)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eReset Button:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003ePress \u0026lt; 3 seconds to reboot, \u0026gt; 3 seconds for factory reset\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eFirmware Updates:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eRemote updates via web interface\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003eEnvironmental Specifications\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eOperating Temperature:\u003c\/span\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003ePoE Mode:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e-20°C to 70°C (-4°F to 158°F)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eUSB Mode:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e-40°C to 85°C (-40°F to 185°F)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eStorage Temperature:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e-40°C to 85°C\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eHumidity:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e5% to 95% RH, non-condensing\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eCertifications:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eCE, FCC Class A (Industrial use), RoHS compliant\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003ePhysical Specifications\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eDimensions:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e54.5mm (W) x 102.5mm (L) x 24.5mm (H) (2.15\" x 4.04\" x 0.96\")\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eWeight:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e79g (2.79 oz)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eMounting:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eDesktop (compact footprint)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eEnclosure:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eIndustrial-grade plastic housing\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eConnectors:\u003c\/span\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e1 x DB9 Male (RS-232\/422\/485)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e1 x RJ-45 (Ethernet with PoE PD)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e1 x Micro-USB Type B (Power input - alternative to PoE)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e1 x Reset button (Tact switch)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr class=\"my-7 border-neutral-300 dark:border-neutral-700\"\u003e\n\u003ch2 class=\"mb-2 mt-4 break-words text-xl font-semibold\"\u003eReal-World Applications\u003c\/h2\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e🏭\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eIndustrial Automation \u0026amp; SCADA\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eConnect PLCs, RTUs, and industrial controllers to SCADA systems\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eMulti-drop RS-485 networks for sensor arrays and I\/O modules\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eRemote monitoring and control of manufacturing equipment\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eBuilding automation and energy management systems\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eFactory floor data collection and distribution\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eRobot arms and human-machine interfaces\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eLogistics warehouse rail systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e🏥\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eHealthcare \u0026amp; Medical Equipment\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eNetwork legacy diagnostic equipment and patient monitors\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eLaboratory automation and LIMS integration\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eMedical imaging device connectivity\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eExamination equipment controllers\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eMeasuring instruments and gas detectors\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eHospital infrastructure management\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e🚂\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eTransportation \u0026amp; Infrastructure\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eRailway signaling and control systems\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eTraffic management and ITS (Intelligent Transportation Systems)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eAirport ground support equipment\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eParking management and access control\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eLogistics and conveyor belt systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e⚡\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eEnergy \u0026amp; Utilities\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eSmart grid monitoring and control\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003ePower management devices\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eRemote meter reading (AMR\/AMI)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eWater quality and pollution measuring instruments\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eEnvironmental monitoring stations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e📡\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eTelecommunications\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eSerial console access to network equipment\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eRemote management of telecom infrastructure\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eBase station monitoring and control\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eNetwork operations center (NOC) equipment\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e🏪\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eRetail \u0026amp; Point of Sale\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eCard readers and barcode scanners\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003ePOS devices and kiosks\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSerial printers and ATM machines\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eCredit card terminals and readers\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eInventory management systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e🔬\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eLaboratory \u0026amp; Research\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eNetwork analytical instruments and data loggers\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eControllers on inspection equipment\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eAutomated testing equipment\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eQuality control systems\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eResearch data acquisition\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e🏗️\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eSecurity \u0026amp; Access Control\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eBiometric sensors and alarm devices\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eCard readers and access control panels\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eCCTV camera control (PTZ)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eIntrusion detection systems\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSecurity devices\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e🎮\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eConsumer Electronics \u0026amp; Home Automation\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eGame console connectivity\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eHome appliance networking\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003ePower management devices\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eData collection and distribution devices\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr class=\"my-7 border-neutral-300 dark:border-neutral-700\"\u003e\n\u003ch2 class=\"mb-2 mt-4 break-words text-xl font-semibold\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e✓\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003esLAN\/all-PoE Serial to Ethernet Converter\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e(1 unit)\u003cbr\u003e✓\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eLAN Cable\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e(Ethernet cable)\u003cbr\u003e✓\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eEjector Pin\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e(for DB9 connector)\u003cbr\u003e✓\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eProduct Warranty \u0026amp; Download Guide\u003c\/span\u003e\u003cbr\u003e✓\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eSoftware available for download:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eCOM Port Redirector (Virtual COM Port driver)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSGConfig (Configuration utility)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eTestView (Testing software)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eUser manual (PDF)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eNote:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003ePoE injector sold separately if your network switch doesn't support PoE. Micro-USB power cable not included (standard 5V Micro-USB cable can be used if PoE is unavailable).\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cem class=\"italic\"\u003eAll software is available for download from the SystemBase website. See the link under the \u003cstrong\u003eTechnical Support \u0026amp; Resources\u003c\/strong\u003e section below.\u003c\/em\u003e\u003c\/p\u003e\n\u003chr class=\"my-7 border-neutral-300 dark:border-neutral-700\"\u003e\n\u003ch2 class=\"mb-2 mt-4 break-words text-xl font-semibold\"\u003eQuick Setup Guide\u003c\/h2\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eStep 1: Choose Your Power Source\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cstrong\u003e\u003cspan class=\"font-semibold\"\u003eOption A - Power over Ethernet (Recommended):\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eConnect Ethernet cable from PoE-enabled switch (IEEE 802.3af) to sLAN\/all-PoE\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eDevice powers on automatically\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eRDY LED will blink when device is operating\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eOperating temperature range: -20°C to 70°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cstrong\u003e\u003cspan class=\"font-semibold\"\u003eOption B - Micro-USB Power:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eConnect 5V DC power via Micro-USB Type B connector\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eConnect standard Ethernet cable (non-PoE)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eRDY LED will blink when device is operating\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eOperating temperature range: -40°C to 85°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eStep 2: Choose Your Serial Interface\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eThe sLAN\/all-PoE uses a single DB9 Male connector that supports all three serial modes. Configure the interface type via the web interface or SGConfig utility.\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cstrong\u003e\u003cspan class=\"font-semibold\"\u003eFor RS-232:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eConnect your RS-232 device to the DB9 port\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eConfigure Interface setting to \"RS-232\" in web interface\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003ePins: TXD(3), RXD(2), RTS(7), CTS(8), DTR(4), DSR(6), DCD(1), RI(9), GND(5)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cstrong\u003e\u003cspan class=\"font-semibold\"\u003eFor RS-422:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eConnect your RS-422 device to the DB9 port\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eConfigure Interface setting to \"RS-422\" in web interface\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eConfigure RS-422 Multi-Drop Mode (Master or Slave)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003ePins: TXD+(2), TXD-(1), RXD+(3), RXD-(7), GND(5)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cstrong\u003e\u003cspan class=\"font-semibold\"\u003eFor RS-485:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eConnect your RS-485 device to the DB9 port\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eConfigure Interface setting to \"RS-485\" in web interface\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eEnable\/disable termination resistor as needed\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003ePins: TRXD+(2), TRXD-(1), GND(5)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eStep 3: Network Configuration\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cstrong\u003e\u003cspan class=\"font-semibold\"\u003eOption A - Use Default IP Address:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eConfigure your PC to access 192.168.0.x network\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eOpen web browser and navigate to\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"http:\/\/192.168.0.223\/\" rel=\"noopener noreferrer\" class=\"cursor-pointer break-words text-[#2964AA] hover:opacity-80 dark:text-[#7AB7FF]\" target=\"_blank\"\u003ehttp:\/\/192.168.0.223\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eLogin with default credentials (ID: slan, Password: 99999999)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cstrong\u003e\u003cspan class=\"font-semibold\"\u003eOption B - Use SGConfig Utility:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eRun SGConfig on Windows PC\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eClick [Search] to discover sLAN\/all-PoE devices on network\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSelect device and click [Configure]\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eImportant:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eWeb configuration requires 100Mbps network connection. For 10Mbps networks, use SGConfig utility instead.\u003c\/p\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eStep 4: Configure Settings\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eNetwork Settings:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eSet Static IP or DHCP, configure IP address, subnet mask, gateway\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eOperation Settings:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eSelect operation mode (COM Redirector, TCP Server\/Client, UDP Server\/Client)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eSerial Settings:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eConfigure interface (RS-232\/422\/485), baud rate, data bits, stop bits, parity, flow control\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eClick [Submit] to save changes\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eClick [Reboot] to apply settings\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eStep 5: Test \u0026amp; Deploy\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eUse TestView software to verify communication\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eInstall COM Port Redirector if using virtual COM port mode\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eMonitor status via web interface or SGConfig\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eTotal setup time: 5-10 minutes\u003c\/span\u003e\u003c\/p\u003e\n\u003chr class=\"my-7 border-neutral-300 dark:border-neutral-700\"\u003e\n\u003ch2 class=\"mb-2 mt-4 break-words text-xl font-semibold\"\u003eAdvanced Features \u0026amp; Capabilities\u003c\/h2\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003ePower over Ethernet Benefits\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cstrong\u003e\u003cspan class=\"font-semibold\"\u003eSimplified Installation:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eSingle cable for both data and power\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eNo need for nearby AC outlets\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eReduced installation time and cost\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eCleaner, more professional installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cstrong\u003e\u003cspan class=\"font-semibold\"\u003eRemote Locations:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003ePower devices where AC power isn't available\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eCeiling-mounted installations\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eOutdoor enclosures (with weatherproof housing)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eHard-to-reach locations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cstrong\u003e\u003cspan class=\"font-semibold\"\u003eCentralized Power Management:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eUPS backup for all PoE devices from central location\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eRemote power cycling via managed PoE switches\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003ePower monitoring and management\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eReduced power adapter inventory\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cstrong\u003e\u003cspan class=\"font-semibold\"\u003eFlexibility:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eFall back to Micro-USB power if PoE unavailable\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eMix PoE and non-PoE installations as needed\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eCompatible with any IEEE 802.3af PoE source\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eFlexible Serial Interface Selection\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eThe sLAN\/all-PoE uses a single DB9 connector that supports all three serial standards:\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eSoftware configuration\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e- Switch between RS-232, RS-422, and RS-485 via web interface\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eNo hardware jumpers\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e- All configuration done through software\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003ePin mapping\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e- Automatic pin assignment based on selected interface\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eHot-swappable\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003ebetween modes (after reboot)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eRS-485 Multi-Drop Networking\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003ePerfect for industrial applications requiring multiple devices on one network:\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eSupport for up to 32 devices per RS-485 bus\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSoftware-configurable termination resistors (120Ω)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eHalf-duplex communication\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eTransparent data transmission\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eCompatible with Modbus RTU, Profibus, BACnet MS\/TP, and other protocols\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eRS-422 Multi-Drop Mode\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eUnique RS-422 multi-drop capability:\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eMaster mode:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eFor primary controller\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eSlave mode:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eFor secondary devices\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003ePoint-to-point:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eSet both devices to Master for 1:1 connections\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eFull-duplex communication\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eLong-distance support up to 4,000 feet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eVirtual COM Port Technology\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eThe included COM Port Redirector creates virtual COM ports on Windows systems:\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eLegacy applications work without modification\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSupports multiple virtual ports simultaneously\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eAutomatic reconnection on network interruption\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eCompatible with Windows 7 and above\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eMultiple Operating Modes\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cstrong\u003e\u003cspan class=\"font-semibold\"\u003eCOM Redirector Mode:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eCreates virtual COM port on Windows PC\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSerial port settings follow virtual COM port configuration\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003ePerfect for legacy software compatibility\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eNo application changes required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cstrong\u003e\u003cspan class=\"font-semibold\"\u003eTCP Server Mode:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eDevice listens for incoming connections on configured port (default: 4001)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eMultiple clients can connect simultaneously\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eTransparent data transfer between socket and serial port\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eIdeal for centralized monitoring applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cstrong\u003e\u003cspan class=\"font-semibold\"\u003eTCP Client Mode:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eDevice initiates connection to remote server\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eConfigure target IP address and port\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eAutomatic reconnection on network interruption\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003ePerfect for data logging and cloud integration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cstrong\u003e\u003cspan class=\"font-semibold\"\u003eUDP Server Mode:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eReceives UDP packets on configured port\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eForwards data to serial port\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSends serial data as UDP packets to client\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eLow-latency communication\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cstrong\u003e\u003cspan class=\"font-semibold\"\u003eUDP Client Mode:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eSends serial data as UDP packets to configured server\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eConfigure target IP address and port\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eIdeal for broadcast\/multicast applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eIntelligent Data Handling\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cstrong\u003e\u003cspan class=\"font-semibold\"\u003eLatency Time Configuration:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eSet to 0 for real-time operation (immediate forwarding)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSet to non-zero to buffer data and reduce network traffic\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eConfigurable in milliseconds\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eBalances real-time performance vs. network efficiency\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cstrong\u003e\u003cspan class=\"font-semibold\"\u003eTCP Alive Check:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eMonitors network connection health at configured intervals (default: 60 seconds)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eAutomatically terminates\/resets failed connections\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eConfigurable from 0-65,535 seconds\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSet to 0 to disable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cstrong\u003e\u003cspan class=\"font-semibold\"\u003eTCP No-Delay Option:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eDisabled:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eBuffers TCP data before processing (better for high-speed\/packet-based)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eEnabled:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eProcesses TCP data immediately (minimizes delay)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eOptimizes for different application requirements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eNetwork Discovery \u0026amp; Management\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eAutomatic device discovery\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003evia SGConfig utility\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eWeb-based configuration\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eaccessible from any browser (requires 100Mbps connection)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003ePassword protection\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003efor secure access\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eFactory reset\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003evia reset button (press \u0026gt; 3 seconds)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eRemote firmware updates\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003evia web interface\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eReal-time status monitoring\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003ewith LED indicators\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eAuto-MDIX Support\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eAutomatically detects straight or crossover Ethernet cables\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eNo need for specific cable types\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSimplifies installation and reduces errors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr class=\"my-7 border-neutral-300 dark:border-neutral-700\"\u003e\n\u003ch2 class=\"mb-2 mt-4 break-words text-xl font-semibold\"\u003eSoftware Suite\u003c\/h2\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eCOM Port Redirector (Virtual COM Port Driver)\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eCreates virtual COM ports on Windows systems, allowing legacy serial applications to communicate over the network without modification.\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eFeatures:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eMultiple virtual COM ports per device\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eAutomatic reconnection\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eFlow control support\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eCompatible with Windows 7 and above\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eHow it works:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eWhen Operation Mode is set to \"COM Redirector,\" the sLAN\/all-PoE serial port appears as a local COM port on your Windows PC. Your existing serial software works without any changes.\u003c\/p\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eSGConfig Configuration Utility\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eComprehensive Windows application for device management:\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eFeatures:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eAutomatic device discovery on network\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eIntuitive GUI for all configuration parameters\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eBatch configuration for multiple devices\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eReal-time monitoring and diagnostics\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eConfiguration backup and restore\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eCompatible with Windows 7 and above\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eWorks with both 10Mbps and 100Mbps networks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eTestView Testing Software\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eProfessional testing and diagnostic tool:\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eFeatures:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eSerial port communication testing\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eNetwork connectivity verification\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eData transmission monitoring\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eProtocol analysis\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003ePerformance benchmarking\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eTroubleshooting wizards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr class=\"my-7 border-neutral-300 dark:border-neutral-700\"\u003e\n\u003ch2 class=\"mb-2 mt-4 break-words text-xl font-semibold\"\u003eRS-485 Configuration Guide\u003c\/h2\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eTermination Resistors\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eRS-485 networks require 120Ω termination resistors at both ends of the bus:\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eEnable termination\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eon the first and last devices only via web interface\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eDisable termination\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eon all middle devices\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSoftware-configurable (no hardware jumpers required)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eImproper termination causes communication errors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eWiring Best Practices\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eUse\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003etwisted pair cable\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e(Cat5e or better, or dedicated RS-485 cable)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eKeep\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003etotal bus length under 4,000 feet\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e(1,200m)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eUse\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003edaisy-chain topology\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e(not star)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eAvoid\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003estubs\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003elonger than 1 meter\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eMaintain\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eproper grounding\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eto prevent ground loops\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eUse\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eshielded cable\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003ein electrically noisy environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003ePin Assignment for RS-485\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003ePin 1:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eTRXD- (Data-)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003ePin 2:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eTRXD+ (Data+)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003ePin 5:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eGND (Ground)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eMulti-Drop Addressing\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eFor RS-485 networks with multiple devices:\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eEach device needs a\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eunique address\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e(configured in serial device)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003esLAN\/all-PoE acts as\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003etransparent bridge\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e(no addressing required)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eUse\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eModbus RTU\u003c\/span\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eProfibus\u003c\/span\u003e, or other multi-drop protocols\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eConfigure\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eappropriate timeout\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003evalues for polling applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr class=\"my-7 border-neutral-300 dark:border-neutral-700\"\u003e\n\u003ch2 class=\"mb-2 mt-4 break-words text-xl font-semibold\"\u003eRS-422 Multi-Drop Configuration\u003c\/h2\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eMaster\/Slave Mode\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eThe sLAN\/all-PoE supports RS-422 multi-drop configurations:\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eMaster Mode:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eSet for the primary controller device\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eTransmits data to multiple slave devices\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eSlave Mode:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eSet for secondary devices\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eReceives data from master\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003ePoint-to-Point (1:1):\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eSet both connected devices to Master mode\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eStandard RS-422 full-duplex communication\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003ePin Assignment for RS-422\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003ePin 1:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eTXD- (Transmit-)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003ePin 2:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eTXD+ (Transmit+)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003ePin 3:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eRXD+ (Receive+)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003ePin 7:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eRXD- (Receive-)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003ePin 5:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eGND (Ground)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr class=\"my-7 border-neutral-300 dark:border-neutral-700\"\u003e\n\u003ch2 class=\"mb-2 mt-4 break-words text-xl font-semibold\"\u003ePoE Deployment Guide\u003c\/h2\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003ePoE Switch Requirements\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eThe sLAN\/all-PoE requires an IEEE 802.3af compliant PoE source:\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003ePoE Standard:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eIEEE 802.3af (PoE, not PoE+)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003ePower Class:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eClass 0 (0.44W to 12.95W)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eActual Consumption:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e0.6W (operating \u0026amp; standby)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eVoltage:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e48V DC nominal\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eCompatible PoE Sources\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eManaged PoE Switches:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eEnterprise-grade switches with per-port PoE management\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eRemote power cycling capability\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003ePower monitoring and budgeting\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eVLAN and QoS support\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eUnmanaged PoE Switches:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eSimple plug-and-play operation\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eLower cost for small deployments\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eNo configuration required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003ePoE Injectors (Midspan):\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eSingle-port PoE injectors for non-PoE switches\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eMulti-port injectors for multiple devices\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eIdeal for adding PoE to existing infrastructure\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eCable Requirements\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eCable Type:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eCat5e or better (Cat6, Cat6a recommended)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eMaximum Length:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e100 meters (328 feet) per IEEE 802.3af standard\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eShielding:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eUse shielded cable in electrically noisy environments\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eQuality:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eUse quality cables to ensure reliable PoE delivery\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eTemperature Considerations\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003ePoE Mode Operating Range:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e-20°C to 70°C (-4°F to 158°F)\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eMost industrial environments fall within this range\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eFor extreme cold (\u0026lt; -20°C), use Micro-USB power instead\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eFor extreme heat (\u0026gt; 70°C), use Micro-USB power instead\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003ePoE mode provides adequate range for most applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eUSB Mode Operating Range:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e-40°C to 85°C (-40°F to 185°F)\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eExtended range for extreme environments\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eUse when PoE temperature limits are exceeded\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eRequires separate power adapter\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr class=\"my-7 border-neutral-300 dark:border-neutral-700\"\u003e\n\u003ch2 class=\"mb-2 mt-4 break-words text-xl font-semibold\"\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eQ: What's the difference between the sLAN\/all-PoE and the \u003ca href=\"https:\/\/envistiamall.com\/products\/serial-rs232-rs422-rs485-to-ethernet-converter-slan\" target=\"_blank\" title=\"SystemBase sLAN\/All Serial to Ethernet Converter (RS-232\/422\/485)\" rel=\"noopener\"\u003esLAN\/All\u003c\/a\u003e?\u003c\/span\u003e\u003cbr\u003eA: The sLAN\/all-PoE includes Power over Ethernet (IEEE 802.3af) capability, allowing it to be powered directly from a PoE switch. The V2.0 model requires external 5V DC power. The PoE model is also slightly larger (102.5mm vs 72mm length) to accommodate PoE circuitry. Both models have identical serial and network capabilities.\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eQ: Do I need a PoE switch, or can I use a PoE injector?\u003c\/span\u003e\u003cbr\u003eA: Either works! You can use a PoE-enabled network switch or a PoE injector (IEEE 802.3af). PoE injectors are ideal for adding PoE capability to existing non-PoE switches.\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eQ: Can I use regular (non-PoE) Ethernet and power it via Micro-USB?\u003c\/span\u003e\u003cbr\u003eA: Yes! The sLAN\/all-PoE has dual power options. You can use PoE for clean installations or Micro-USB (5V DC) when PoE isn't available. This provides maximum deployment flexibility.\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eQ: What's the operating temperature range when using PoE?\u003c\/span\u003e\u003cbr\u003eA: When powered by PoE, the operating temperature range is -20°C to 70°C (-4°F to 158°F). When powered by Micro-USB, the range extends to -40°C to 85°C (-40°F to 185°F).\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eQ: How much power does the sLAN\/all-PoE consume?\u003c\/span\u003e\u003cbr\u003eA: Very little! PoE mode consumes only 0.6W (operating \u0026amp; standby). USB mode consumes 1.0W operating, 0.9W standby, with a maximum of 1.2W. This makes it extremely energy-efficient.\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eQ: How do I switch between RS-232, RS-422, and RS-485 modes?\u003c\/span\u003e\u003cbr\u003eA: All configuration is done through software via the web interface or SGConfig utility. Simply select the desired interface type in the Serial Settings page and reboot the device. No hardware jumpers required.\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eQ: What's the maximum number of devices on an RS-485 network?\u003c\/span\u003e\u003cbr\u003eA: The sLAN\/all-PoE supports up to 32 devices per RS-485 bus. For larger networks, use RS-485 repeaters.\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eQ: Can I configure the device via web browser on a 10Mbps network?\u003c\/span\u003e\u003cbr\u003eA: No, web configuration requires a 100Mbps network connection. For 10Mbps networks, use the SGConfig utility instead, which works with both 10Mbps and 100Mbps connections.\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eQ: What operating systems are supported?\u003c\/span\u003e\u003cbr\u003eA: The device works with any OS that supports TCP\/IP (Windows, Linux, macOS, Unix, etc.). The COM Port Redirector and SGConfig utilities require Windows 7 or above, but the web interface works in any modern browser.\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eQ: How do I reset the device to factory defaults?\u003c\/span\u003e\u003cbr\u003eA: Press and hold the RST button on the rear panel for more than 3 seconds. The device will reset to factory default settings (IP: 192.168.0.223, ID: slan, Password: 99999999).\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eQ: Can I use straight or crossover Ethernet cables?\u003c\/span\u003e\u003cbr\u003eA: Either! The sLAN\/all-PoE supports Auto-MDIX, which automatically detects and adapts to both cable types.\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eQ: What is the default IP address?\u003c\/span\u003e\u003cbr\u003eA: The default IP address is 192.168.0.223 with subnet mask 255.255.255.0 and gateway 192.168.0.254.\u003c\/p\u003e\n\u003chr class=\"my-7 border-neutral-300 dark:border-neutral-700\"\u003e\n\u003ch2 class=\"mb-2 mt-4 break-words text-xl font-semibold\"\u003eTechnical Support \u0026amp; Resources\u003c\/h2\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\u003ca href=\"https:\/\/envistia.com\/documents\/sLAN_PoE_UserManual_Eng.pdf\" title=\"SystemBase sLAN\/All POE User Manual (PDF)\" rel=\"noopener\" target=\"_blank\"\u003eDownload the sLAN\/All POE User Manual (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\u003ca href=\"https:\/\/www.sysbas.com\/en\/downloads\/slan-all-2\/\" title=\"SystemBase sLAN\/All POE Software and Utilities Downloads\" rel=\"noopener\" target=\"_blank\"\u003eDownload Configuration Software and Utilities (SystemBase Website)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eNeed help? Contact our technical support team at\u003cspan\u003e \u003c\/span\u003e\u003ca class=\"cursor-pointer break-words text-[#2964AA] hover:opacity-80 dark:text-[#7AB7FF]\" href=\"mailto:support@envistiamall.com\"\u003esupport@envistiamall.com\u003c\/a\u003e\u003c\/p\u003e","brand":"SystemBase","offers":[{"title":"Default Title","offer_id":42077884580089,"sku":"sLAN\/all-PoE","price":148.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1641\/0911\/products\/poe-serial-rs232-rs422-rs485-to-ethernet-converter-slanall-poe-503992.jpg?v=1637738889"},{"product_id":"serial-rs232-rs422-rs485-to-wifi-converter-swifi","title":"Serial RS232 \/ RS422 \/ RS485 to WiFi 802.11a\/b\/g\/n Converter Systembase sWiFi\/all","description":"\u003cp\u003eThe SYSTEMBASE sWiFi\/all is a small-size dual-band wireless gateway that provides WiFi (IEEE 802.11a\/b\/g\/n, 2.4GHz\/5GHz) communication for RS232\/RS422\/RS485 equipment. Equipped with a serial standard DB9 connector, sWiFi\/all can be easily used with RS232 or RS422\/485 equipment, providing wired communication speed up to 921.6Kbps and wireless up to 54Mbps.\u003c\/p\u003e\n\u003cp\u003esWiFi\/all includes the COM Port Redirector program to support remote control, monitoring, and data communication of connected devices over the network(TCP\/IP), and the connected serial devices can be used instantly without any program modifications.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIEEE 802.11 a\/b\/g\/n\u003c\/li\u003e\n\u003cli\u003e2.4GHz, 5GHz Dual Band\u003c\/li\u003e\n\u003cli\u003eRS232\/422\/485: 1 DB9 port\u003c\/li\u003e\n\u003cli\u003eMaximum Serial Communication Speed: 921.6Kbps\u003c\/li\u003e\n\u003cli\u003eIndustrial Grade Operating Temp.: -40 ~ 85℃ (-40 ~ 185℉)\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eIncludes COM Port Redirector, TestView, \u0026amp; sWiFiConfig Software\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eBuilt-in ±15kV IEC ESD Protection\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eDC 5~12V\/1A Adapter, Consumption: 2W\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eInfrastucture: Soft AP, Roaming\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eIncludes sWiFiConfig Mobile App (Android only)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSupports 2.4GHz \u0026amp; 5GHz Dual Band\u003c\/h3\u003e\n\u003cp\u003esWiFi\/all provides WiFi communication in the 5GHz band in addition to the 2.4GHz band. By using the 5GHz band, users can avoid confusion in the 2.4GHz band and can use a wireless network with enhanced communication reliability.\u003c\/p\u003e\n\u003ch3\u003eSupports Various Communication Modes\u003c\/h3\u003e\n\u003cp\u003eVia a wireless network, sWiFi\/all can easily communicate, control, and monitor serial equipment at remote locations. It can utilize various communication modes such as Station mode that can be connected to AP and one-to-one communication.\u003c\/p\u003e\n\u003ch3\u003eHigh Performance and Reliability\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003eConsidering the unstable power in the industrial field, protection against over-voltage, over-current, and reverse voltage are provided, as well as the use of reliable components in its design for superior reliability and high performance.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSoftware Utilities Provided\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003eThe SerialGate series converters come with the following utilities:\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCOM Port Redirector:\u003c\/strong\u003e This utility allows the users to add virtual ports to the PC without modifying the client software to enable serial communication.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTestView™:\u003c\/strong\u003e A utility for checking the performance and stability of the data communication between the serial ports and Ethernet ports.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003esWiFiConfig:\u003c\/strong\u003e Simple setup utility for Windows which provides easy and convenient setup and monitoring\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ch4\u003eNetwork\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eSpecification: IEEE 802.11 a\/b\/g\/n\u003c\/li\u003e\n\u003cli\u003eMaximum Speed(WiFi): 54Mbps\u003c\/li\u003e\n\u003cli\u003eDistance Range: Up to 100m (in Open Area)\u003c\/li\u003e\n\u003cli\u003eAir Interface: ISM bands 2.4GHz\/ 5GHz\u003c\/li\u003e\n\u003cli\u003eEncryption: Open, WEP, WPA-PSK, WPA2-PSK, WPA-Enterprise, WPA2-Enterprise\u003c\/li\u003e\n\u003cli\u003eAntenna: Dipole Antenna \/ Avg 1.5dBi\/2.4GHz, -0.7dBi\/5GHz\u003c\/li\u003e\n\u003cli\u003eMode: Station, Peer to Peer\u003c\/li\u003e\n\u003cli\u003eProtocol: COM Redirector, TCP Server\/Client, UDP\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSerial\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eNumber of ports: 1 Serial Port\u003c\/li\u003e\n\u003cli\u003eInterface RS232\/422\/485: DE9 Female\u003c\/li\u003e\n\u003cli\u003eMaximum Speed: 921.6 Kbps\u003c\/li\u003e\n\u003cli\u003eSignal Lines:\u003c\/li\u003e\n\u003cul\u003e\n\u003cli\u003eRS232: TXD, RXD, RTS, CTS, DTR, DSR, DCD\u003c\/li\u003e\n\u003cli\u003eRS422: TXD+, TXD-, RXD+, RXD\u003c\/li\u003e\n\u003cli\u003eRS485: TRXD+, TRXD-\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003eData Bits: 5, 6, 7, 8\u003c\/li\u003e\n\u003cli\u003eStop Bits: 1, 2\u003c\/li\u003e\n\u003cli\u003eParity Bits: None, Even, Odd\u003c\/li\u003e\n\u003cli\u003eFlow Control: None, RTS, CTS, RTS\/CTS\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSoftware\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eOS: RTOS\u003c\/li\u003e\n\u003cli\u003eManagement Tools: TestView™\u003c\/li\u003e\n\u003cli\u003eConfiguration: Web, SGConfig\u003c\/li\u003e\n\u003cli\u003eUtility (Supported OS): COM Redirector for Windows 7 and above\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eHardware\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eLED: RDY(Ready), TXD(Serial), RXD(Serial)\u003c\/li\u003e\n\u003cli\u003ePower Requirement: DC 5~12V\/1A Adapter, Consumption: 2W, External: Φ3.5mm, Internal: Φ1.35mm\u003c\/li\u003e\n\u003cli\u003eDimensions (W x L x H): 40.9 x 90.1 x 16.5mm \/ 1.6 x 3.5 x 0.6in\u003c\/li\u003e\n\u003cli\u003eWeight: 32.1g \/ 1.13oz\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOperating Environment\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eOperating Temperature: -40 ~ 85 °C\u003c\/li\u003e\n\u003cli\u003eStoring Temperature: -40 ~ 85 °C\u003c\/li\u003e\n\u003cli\u003eHumidity: 5 ~ 90% Non-Condensing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eCertifications\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eCertifications KC, FCC, CE\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePackage Includes:\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp style=\"padding-left: 30px;\"\u003e1X sWiFi Serial RS232 \/ RS422 \/ RS485 to WiFi Converter\u003cbr\u003eEjector pin, 5V DC Adapter, Dipole Antenna (Dual Band),\u003cbr data-mce-fragment=\"1\"\u003eDownload Guide, Warranty Policy\u003c\/p\u003e\n\u003ch3\u003eAdditional Resources:\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.sysbas.com\/en\/portfolio-item\/swifi\/\" title=\"sWiFi Serial RS232 \/ RS422 \/ RS485 to Wifi Converter\" target=\"_blank\"\u003esWiFi Serial RS232 \/ RS422 \/ RS485 to Wifi Converter Manual, Utilities and Specifications Downloads (SystemBase Website)\u003c\/a\u003e\u003c\/p\u003e","brand":"SystemBase","offers":[{"title":"Default Title","offer_id":42077917806841,"sku":"sWiFi-All","price":159.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1641\/0911\/products\/serial-rs232-rs422-rs485-to-wifi-converter-swifi-328149.jpg?v=1637738890"},{"product_id":"cse-m73g-serial-rs232-rs422-rs485-to-ethernet-network-module","title":"Sollae Systems CSE-M73G Embedded Serial to Ethernet Module with RJ-45 RS232\/RS422\/RS485","description":"\u003cp class=\"mb-2 mt-4 break-words text-xl font-semibold\"\u003eCompact OEM serial to Ethernet Module with Integrated RJ-45 Connector: Integ\u003cspan class=\"font-semibold\"\u003erate professional-grade serial-to-Ethernet connectivity directly into your products with this compact 64mm x 40mm module featuring a built-in RJ-45 connector and multiple serial interface options.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eThe Sollae Systems CSE-M73G is an industrial-grade embedded serial-to-Ethernet module designed for OEM integration into equipment, instruments, and devices. With its compact footprint (64.3mm x 40mm x 17mm), integrated RJ-45 connector, built-in RS-232\/RS-422\/RS-485 interfaces, pin-compatible design with CSE-M73\/M73A, and support for both IPv4 and IPv6, the CSE-M73G delivers enterprise-level networking performance in a package perfect for embedded applications requiring ready-to-use Ethernet connectivity.\u003c\/p\u003e\n\u003chr class=\"my-7 border-neutral-300 dark:border-neutral-700\"\u003e\n\u003ch2 class=\"mb-2 mt-4 break-words text-xl font-semibold\"\u003eWhy Choose the CSE-M73G?\u003c\/h2\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e🔌\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eIntegrated RJ-45 Connector\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eBuilt-in RJ-45 connector with integrated magnetics eliminates the need for external Ethernet components. Simply plug in a standard Ethernet cable and you're connected—no additional circuitry required.\u003c\/p\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e🔧\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eBuilt-In Serial Interfaces\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eComplete RS-232, RS-422, and RS-485 interface circuitry built into the module. No external level shifters or transceivers needed—just connect your serial device to the appropriate header.\u003c\/p\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e📦\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eCompact OEM Design\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eAt 64.3mm x 40mm x 17mm and weighing only 17g, the CSE-M73G provides a complete serial-to-Ethernet solution in a compact package perfect for embedding directly into your products.\u003c\/p\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e🔄\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003ePin-Compatible with CSE-M73\/M73A\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eDrop-in compatible design allows easy migration from CSE-M73 or CSE-M73A modules. Standardize on one footprint across your product line while leveraging the latest features.\u003c\/p\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e🔌\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eVersatile Serial Interfaces\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eSupport for RS-232, RS-422, RS-485, AND 3.3V UART—all from one module. Choose the interface that matches your application with simple connector selection.\u003c\/p\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e🌐\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eFuture-Proof IPv6 Support\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eFull IPv4\/IPv6 dual stack implementation with stateless and stateful (DHCPv6) address auto-configuration. Ready for modern networks and future IPv6 deployments.\u003c\/p\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e🏭\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eIndustrial-Grade Reliability\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eExtreme temperature range (-40°C to +85°C) and robust design make this module perfect for harsh industrial environments where consumer-grade components fail.\u003c\/p\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e🔒\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eEnhanced Security\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eBuilt-in TLS v1.2 encryption, IP\/MAC filtering, and password protection ensure your serial data remains secure across the network.\u003c\/p\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e🔄\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eMultiple Connection Support\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eMonitor and control from up to 8 locations simultaneously. Multiple clients can connect to a single CSE-M73G for distributed monitoring and control applications.\u003c\/p\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e⚡\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eHigh-Speed Performance\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eUART support up to 230.4 kbps ensures fast, reliable data transfer for even the most demanding serial applications.\u003c\/p\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e🎯\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eEasy Integration\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eStandard 2.54mm pitch pin headers, integrated RJ-45 connector, comprehensive documentation, and free configuration software make integration straightforward.\u003c\/p\u003e\n\u003chr class=\"my-7 border-neutral-300 dark:border-neutral-700\"\u003e\n\u003ch2 class=\"mb-2 mt-4 break-words text-xl font-semibold\"\u003eCSE-M73G Technical Specifications\u003c\/h2\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003eSerial Interface\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003ePhysical Interfaces:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eRS-232:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eJP1\/JP2 (6-pin, 2.54mm pitch)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eRS-422\/RS-485:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eJP4\/JP5 (6-pin, 2.54mm pitch)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003e3.3V UART:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eJP3 (6-pin, 2.54mm pitch, 5V tolerant input)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eSerial Parameters:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eBaud Rate:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e300 to 230,400 bps\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eData Bits:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e8 bits, 7 bits (with parity)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eParity:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eNone, Even, Odd, Mark, Space\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eStop Bits:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e1, 2\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eFlow Control:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eNone, RTS\/CTS, XON\/XOFF\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eNote:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e7 data bits with NONE parity is not supported\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eA single idle bit is automatically added after every stop bit by the MCU function\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003eRS-232 Interface (JP1\/JP2)\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003ePin Assignment (6-pin, 2.54mm pitch):\u003c\/span\u003e\u003c\/p\u003e\n\u003col class=\"ml-8 list-outside list-decimal\"\u003e\n\u003cli class=\"py-0.5\"\u003eVCC - DC 5V Power\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eRXD - Receive Data (RS-232 level, Input)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eTXD - Transmit Data (RS-232 level, Output)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eGND - Ground\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eRTS - Request To Send (RS-232 level, Output)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eCTS - Clear To Send (RS-232 level, Input)\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eFeatures:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eFull RS-232 signal support with built-in level shifters\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eHardware flow control (RTS\/CTS)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003ePins with same number on JP1 and JP2 are connected\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eNo external components required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003eRS-422\/RS-485 Interface (JP4\/JP5)\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003ePin Assignment (6-pin, 2.54mm pitch):\u003c\/span\u003e\u003c\/p\u003e\n\u003col class=\"ml-8 list-outside list-decimal\"\u003e\n\u003cli class=\"py-0.5\"\u003eVCC - DC 5V Power\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eTRX+ - TX+ (RS-422) \/ Data+ (RS-485)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eTRX- - TX- (RS-422) \/ Data- (RS-485)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eGND - Ground\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eRX+ - RX+ (RS-422 only)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eRX- - RX- (RS-422 only)\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eFeatures:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eBuilt-in RS-422\/485 transceivers\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eRS-422: Full-duplex, point-to-point or multi-drop\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eRS-485: Half-duplex, multi-drop up to 32 devices\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003ePins with same number on JP4 and JP5 are connected\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eNote:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eModule does not include termination resistors (add externally as needed)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e3.3V UART Interface (JP3)\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003ePin Assignment (6-pin, 2.54mm pitch):\u003c\/span\u003e\u003c\/p\u003e\n\u003col class=\"ml-8 list-outside list-decimal\"\u003e\n\u003cli class=\"py-0.5\"\u003eVCC - DC 5V Power\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eRXD - Receive Data (3.3V level, 5V tolerant input)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eTXD - Transmit Data (3.3V level, Output)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eGND - Ground\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eRTS - Request To Send (3.3V level, Output)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eCTS - Clear To Send (3.3V level, Input)\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eElectrical Characteristics:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eVIH (High-level input):\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e1.5V to 5.5V\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eVIL (Low-level input):\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e-0.3V to 0.9V\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eVOH (High-level output):\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e2.3V min\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eVOL (Low-level output):\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e0.2V max\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003e5V Tolerant Input:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eSafe for direct connection to 5V microcontrollers\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003eNetwork Interface\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eEthernet:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003ePort:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eIntegrated RJ-45 connector with built-in magnetics\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eSpeed:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e10Base-T or 100Base-TX (Auto-Sensing)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eCable Detection:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eAuto MDI\/MDIX (works with straight or crossover cables)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003ePin Assignment:\u003c\/span\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003ePin 1: TX+ (Output)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003ePin 2: TX- (Output)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003ePin 3: RX+ (Input)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003ePin 6: RX- (Input)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eNetwork Protocols:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eIPv4:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eTCP, UDP, IP, ICMP, ARP, DHCP, PPPoE, DNS, DDNS\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eIPv6:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eICMPv6, TCPv6, UDPv6, IPv6 fragmentation\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eIPv6 Configuration:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eStateless and Stateful (DHCPv6) auto-configuration\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eSecurity:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eTLS v1.2 (Secure Socket Layer)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eManagement:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eTelnet\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eAdvanced:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eTelnet COM Port Control Option (RFC 2217)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003eCommunication Modes\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eTCP Server (T2S):\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003ePassive connection mode\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eWaits for incoming TCP client connections\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eDefault local port: 1470\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSupports up to 8 simultaneous connections\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eIdeal for centralized monitoring applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eTCP Client (COD):\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eActive connection mode\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eInitiates connection to remote TCP server\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eConfigurable peer IP address and port\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003ePerfect for data logging and cloud integration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eAT Command Mode (ATC):\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eControl connections dynamically via AT commands\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eBoth active and passive connections supported\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eAllows runtime configuration changes\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003ePatented Sollae Systems technology\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eUDP Mode (U2S):\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eConnectionless communication\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eBroadcast and multicast support\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eLow-latency data transfer\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eN:M topology (many-to-many communication)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003ePower Specifications\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eInput Voltage:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eDC 5V ±10% (4.5V to 5.5V)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eCurrent Consumption:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e95mA typical\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003ePower Input:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eAll VCC\/GND pins on JP1-JP5 can be used\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003ePower Connector:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eStandard 2.54mm pin headers\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003eEnvironmental Specifications\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eOperating Temperature:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e-40°C to +85°C (-40°F to 185°F)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eStorage Temperature:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e-40°C to +85°C\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eHumidity:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e5% to 95% RH, non-condensing\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eCertifications:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eRoHS compliant\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003ePhysical Specifications\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eDimensions:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e64.3mm (W) x 40mm (L) x 17mm (H) (2.53\" x 1.57\" x 0.67\")\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eWeight:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eApproximately 17g (0.6 oz)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eMounting:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eSurface mount via pin headers\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eConnectors:\u003c\/span\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e5 x 6-pin headers (2.54mm pitch)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e1 x RJ-45 connector (integrated)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e1 x ISP jumper (JP6)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003eStatus Indicators (LEDs)\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eRJ-45 Connector LEDs:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eYellow LED (STS):\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eBlinks every second: Obtaining IP address\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eBlinks 4 times: No IP address (DHCP\/PPPoE failure)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eON: TCP connection established\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eBlinks shortly: Sending TCP data\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eOFF: ISP mode\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSimultaneous blink with Green: Serial Configuration mode\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eGreen LED (LINK):\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eON: Ethernet connected\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eOFF: No Ethernet connection\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eBlinks shortly: Receiving TCP data\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003ePower LED:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eRed LED:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eON when power supplied\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr class=\"my-7 border-neutral-300 dark:border-neutral-700\"\u003e\n\u003ch2 class=\"mb-2 mt-4 break-words text-xl font-semibold\"\u003eReal-World Applications\u003c\/h2\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e🏭\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eIndustrial Equipment OEM Integration\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eEmbed networking into PLCs, controllers, and industrial instruments\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eFactory automation equipment\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eProcess control devices\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eManufacturing machinery\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eIndustrial sensors and actuators\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e🔬\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eMedical \u0026amp; Laboratory Equipment\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eDiagnostic equipment networking\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eLaboratory instruments\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eMedical imaging devices\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003ePatient monitoring systems\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eAnalytical equipment\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e🏗️\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eBuilding Automation\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eHVAC controllers\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eLighting control systems\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eAccess control panels\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eFire alarm systems\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eEnergy management devices\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e⚡\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eEnergy \u0026amp; Utilities\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eSmart meters\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003ePower monitoring devices\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSubstation equipment\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSolar inverters\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eBattery management systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e🚗\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eTransportation \u0026amp; Automotive\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eVehicle telematics\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eFleet management devices\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eParking systems\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eTraffic control equipment\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eRailway signaling\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e📡\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eTelecommunications\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eNetwork equipment\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eBase station controllers\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eTelecom infrastructure\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eRemote monitoring devices\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e🎮\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eConsumer Electronics\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eGaming peripherals\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eHome automation devices\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSmart appliances\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eIoT devices\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eEntertainment systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e🔧\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eTest \u0026amp; Measurement\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eOscilloscopes\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eData loggers\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eEnvironmental monitors\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eQuality control equipment\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eCalibration devices\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eThe CSE-M73G is especially suitable for:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.eztcp.com\/en\/applications\/multi-conn\" title=\"Multi Monitoring with the ezTCP CSE-M73A Serial Ethernet Module\" target=\"_blank\"\u003eMulti Monitoring\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.eztcp.com\/en\/applications\/manage-solar\" title=\"Solar Energy Management Systems with the ezTCP CSE-M73A Serial Ethernet Module\" target=\"_blank\"\u003eSolar Energy Management Systems\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr class=\"my-7 border-neutral-300 dark:border-neutral-700\"\u003e\n\u003ch2 class=\"mb-2 mt-4 break-words text-xl font-semibold\"\u003eWhat's Included\u003c\/h2\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e✓\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eCSE-M73G Serial to Ethernet Module\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e(1 unit)\u003cbr\u003e✓\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eDocumentation:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eUser Manual (PDF)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eDatasheet (PDF)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eIntegration guide\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e✓\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eSoftware available for download:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eezManager (Configuration utility for Windows)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eezVSP (Virtual Serial Port driver for Windows)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eezTerm (TCP\/IP communication test tool)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cem class=\"italic\"\u003eAll software is available for download from the Sollae Systems ezTCP website. See the link under the \u003cstrong\u003eTechnical Support \u0026amp; Resources\u003c\/strong\u003e section below.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cstrong\u003e\u003cspan class=\"font-semibold\"\u003eNote:\u003c\/span\u003e This is an OEM module.\u003c\/strong\u003e Power supply (5V DC) required. RS-232\/422\/485 interface circuitry is built-in—just connect your serial device.\u003c\/p\u003e\n\u003chr class=\"my-7 border-neutral-300 dark:border-neutral-700\"\u003e\n\u003ch2 class=\"mb-2 mt-4 break-words text-xl font-semibold\"\u003eQuick Integration Guide\u003c\/h2\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eStep 1: Hardware Connection\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003ePower:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eConnect regulated 5V DC to any VCC\/GND pins on JP1-JP5\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eTypical current: 95mA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eEthernet:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eConnect standard Ethernet cable to integrated RJ-45 connector\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eAuto MDI\/MDIX supports both straight and crossover cables\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eSerial Interface (Choose One):\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eRS-232:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eConnect to JP1 or JP2 (6-pin header)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eRS-422\/RS-485:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eConnect to JP4 or JP5 (6-pin header)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003e3.3V UART:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eConnect to JP3 (6-pin header)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eStep 2: Initial Configuration\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eDefault Settings:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eIP Address:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e10.1.0.1\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eSubnet Mask:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e255.0.0.0\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eLocal Port:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e1470\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eCommunication Mode:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eTCP Server\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eSerial Type:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eRS-232\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eBaud Rate:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e19,200 bps\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eData Format:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e8-N-1 (8 data bits, No parity, 1 stop bit)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eConfiguration Methods:\u003c\/span\u003e\u003c\/p\u003e\n\u003col class=\"ml-8 list-outside list-decimal\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eVia Ethernet:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eUse ezManager to discover and configure\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eVia Serial:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eEnter Serial Configuration mode (ISP jumper \u0026lt; 1 second)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eAT Commands:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eSet communication mode to AT Command and use serial terminal\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eStep 3: Testing\u003c\/span\u003e\u003c\/h3\u003e\n\u003col class=\"ml-8 list-outside list-decimal\"\u003e\n\u003cli class=\"py-0.5\"\u003ePower on the module\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eVerify LED indicators (Power, LINK, STS)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eUse ezManager to discover module on network\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eConfigure network and serial parameters\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eTest data communication using ezTerm or Simple Test feature\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eVerify bidirectional data flow\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eTotal integration time: 1-2 hours (experienced engineers)\u003c\/span\u003e\u003c\/p\u003e\n\u003chr class=\"my-7 border-neutral-300 dark:border-neutral-700\"\u003e\n\u003ch2 class=\"mb-2 mt-4 break-words text-xl font-semibold\"\u003eAdvanced Features \u0026amp; Capabilities\u003c\/h2\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eMultiple Connection Support (Up to 8 Simultaneous)\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eSimultaneous Monitoring:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eUp to 8 TCP clients can connect to one CSE-M73G simultaneously\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003ePerfect for distributed monitoring applications\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eEach client receives the same serial data\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eIdeal for redundant monitoring systems\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eNo additional hardware required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eUse Cases:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eMultiple operators monitoring the same equipment\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eRedundant data logging systems\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eDistributed SCADA architectures\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eMulti-site monitoring applications\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eBackup monitoring stations\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003ePrimary + backup + cloud logging\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eIPv6 Dual Stack Implementation\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eThe CSE-M73G is fully IPv6-ready with comprehensive support:\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eIPv6 Features:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eFull IPv4\/IPv6 dual stack operation\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eStateless address auto-configuration (SLAAC)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eStateful address configuration (DHCPv6)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eIPv6 fragmentation support\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eICMPv6, TCPv6, UDPv6 protocols\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSeamless IPv4\/IPv6 interoperability\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eWhy IPv6 Matters for OEM Products:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eFuture-proof your product line\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eLarger address space for IoT deployments\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eImproved security with IPsec integration\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eBetter support for mobile and distributed devices\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSimplified network configuration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eTLS v1.2 Security\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eSecure Socket Layer Protection:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eEncrypt serial data over the network\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eProtect sensitive information in transit\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eIndustry-standard TLS v1.2 protocol\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eCertificate-based authentication\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003ePrevents eavesdropping and tampering\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eSecurity Features:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eIP address filtering (whitelist\/blacklist)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eMAC address filtering\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003ePassword-protected configuration\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSecure firmware updates\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eAccess control lists\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003ePacket Fragmentation Control\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eSeparator Settings:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eDefine custom packet delimiters\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eControl when data is transmitted over network\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eOptimize for different protocols and applications\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eReduce network overhead\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eImprove application-level parsing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eData Frame Interval:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eConfigure timeout for packet assembly\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eBalance real-time performance vs. network efficiency\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eAdjustable from 0ms (immediate) to custom values\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eOptimize for your specific application\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eTelnet COM Port Control (RFC 2217)\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eRemote Serial Port Control:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eChange serial parameters remotely over network\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eAdjust baud rate, parity, data bits, stop bits\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eControl flow control settings\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eMonitor serial port status\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eNo physical access required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eBenefits:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eRemote troubleshooting and diagnostics\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eDynamic serial parameter adjustment\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eCentralized serial port management\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eReduced field service costs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eDynamic DNS (DDNS) Support\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eAlways Accessible:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eAutomatic DNS updates when IP address changes\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eUse hostname instead of IP address\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003ePerfect for dynamic IP environments\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSupports major DDNS providers\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSimplified remote access\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003ePPPoE Support\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eDirect Internet Connection:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eConnect directly to DSL\/cable modems\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eNo router required for simple deployments\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eAutomatic authentication and connection\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eIdeal for remote installations\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eReduced hardware costs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eAT Command Mode\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003ePatented Dynamic Control:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eChange connection parameters at runtime\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eEstablish\/terminate connections via serial commands\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eNo device reboot required\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003ePerfect for applications requiring dynamic connectivity\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eUnique Sollae Systems technology\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eAT Command Capabilities:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eConfigure IP addresses and ports\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eEstablish TCP connections\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eControl DHCP and PPPoE\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSet DNS servers\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eModify timeout values\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSave settings to flash memory\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr class=\"my-7 border-neutral-300 dark:border-neutral-700\"\u003e\n\u003ch2 class=\"mb-2 mt-4 break-words text-xl font-semibold\"\u003eSoftware Suite\u003c\/h2\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eezManager - Configuration Utility\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eComprehensive Management Tool for Windows:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eFeatures:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eNo installation required (portable application)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eAutomatic device discovery via MAC or IP address\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eIntuitive graphical interface\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eReal-time status monitoring\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eFirmware update management\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eConfiguration backup and restore\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSimple test utility included\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eBatch configuration for multiple devices\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eConfiguration Methods:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eVia Ethernet (LAN)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eVia Serial port\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eRemote configuration via Telnet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eezVSP - Virtual Serial Port Driver\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eWindows Virtual COM Port Driver:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eFeatures:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eCreates virtual COM ports on Windows PC\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eLegacy applications work without modification\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSupports multiple virtual ports\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eAutomatic reconnection on network interruption\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eCompatible with Windows 7\/8\/10\/11\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eNo application changes required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eHow It Works:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eThe CSE-M73G appears as a local COM port on your Windows PC. Your existing serial software communicates with the virtual port, and ezVSP handles all network communication transparently.\u003c\/p\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eezTerm - Communication Test Tool\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eSimple TCP\/IP Testing:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eFeatures:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eQuick TCP\/IP communication testing\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eBoth TCP and UDP support\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eServer and client modes\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eHex and ASCII data display\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eData logging capabilities\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003ePerfect for troubleshooting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr class=\"my-7 border-neutral-300 dark:border-neutral-700\"\u003e\n\u003ch2 class=\"mb-2 mt-4 break-words text-xl font-semibold\"\u003eOperation Modes\u003c\/h2\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eNormal Mode\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eStandard Operation:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eFor normal data communication\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eFour communication modes available (TCP Server, TCP Client, AT Command, UDP)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eConfiguration via ezManager or Telnet\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eReal-time status monitoring\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eDefault operating mode\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eSerial Configuration Mode\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eSerial Port Configuration:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eConfigure via any serial port (RS-232, RS-422, RS-485, or 3.3V UART)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSerial parameters: 115,200 bps, 8-N-1\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eUse ezManager Serial tab\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eNo network connection required\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003ePerfect for initial setup or network troubleshooting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eHow to Enter:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eConnect ISP jumper (JP6) for less than 1 second\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eBoth LEDs blink simultaneously\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eConnect via serial port at 115,200 bps\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eISP Mode (In-System Programming)\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eFirmware Updates:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eFor upgrading firmware\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eBypass security settings (password recovery)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eDirect firmware upload via ezManager\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eFactory reset capability\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eEmergency recovery mode\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eHow to Enter:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eConnect ISP jumper (JP6) for more than 1 second during power-on\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eBoth LEDs turn OFF\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eUpload firmware via ezManager\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr class=\"my-7 border-neutral-300 dark:border-neutral-700\"\u003e\n\u003ch2 class=\"mb-2 mt-4 break-words text-xl font-semibold\"\u003ePin-Compatibility Notes\u003c\/h2\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eCSE-M73 vs CSE-M73A vs CSE-M73G\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003ePhysical Compatibility:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eAll three modules share the same pin-out\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSame 64.3mm x 40mm footprint\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSame connector layout and positions\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eDrop-in replacement possible\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eFunctional Differences:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eCSE-M73G:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eLatest generation, TLS v1.2, enhanced features, up to 8 connections\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eCSE-M73A:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003ePrevious generation\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eCSE-M73:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eOriginal version\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eImportant:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eMCU functions differ between versions\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eFirmware is NOT interchangeable\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eTest compatibility thoroughly before substitution\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSome timing characteristics may vary\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eConsult datasheets for specific differences\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eMigration Recommendations:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eTest CSE-M73G in your application before mass production\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eVerify all features work as expected\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eUpdate firmware to latest version\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eReview any application-specific timing requirements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr class=\"my-7 border-neutral-300 dark:border-neutral-700\"\u003e\n\u003ch2 class=\"mb-2 mt-4 break-words text-xl font-semibold\"\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eQ: What's the difference between CSE-M73G and CSE-M53G?\u003c\/span\u003e\u003cbr\u003eA: The CSE-M73G includes an integrated RJ-45 connector and built-in RS-232\/422\/485 interface circuitry (64.3 x 40 x 17mm, 17g). The CSE-M53G requires external Ethernet components and serial interface circuitry (20 x 24 x 9.1mm, 3.2g). Choose CSE-M73G for easier integration with ready-to-use Ethernet and serial interfaces, CSE-M53G for smallest possible footprint.\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eQ: What's the difference between CSE-M73G and the standalone CSE-H53N converter?\u003c\/span\u003e\u003cbr\u003eA: The CSE-M73G is an OEM module for embedding into your products. The CSE-H53N is a complete standalone converter with enclosure, connectors, and power adapter. Choose CSE-M73G for OEM integration, CSE-H53N for standalone applications.\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eQ: Does the module include RS-232\/422\/485 interface circuitry?\u003c\/span\u003e\u003cbr\u003eA: Yes! Unlike the CSE-M53G which requires external level shifters, the CSE-M73G includes built-in RS-232, RS-422, and RS-485 interface circuitry. Just connect your serial device to the appropriate header (JP1\/JP2 for RS-232, JP4\/JP5 for RS-422\/485, JP3 for 3.3V UART).\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eQ: Can I use multiple serial interfaces simultaneously?\u003c\/span\u003e\u003cbr\u003eA: No, the module has one UART that can be configured for RS-232, RS-422, RS-485, or 3.3V operation. Choose the interface that matches your application and connect to the appropriate header.\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eQ: Does the module include termination resistors for RS-485?\u003c\/span\u003e\u003cbr\u003eA: No, the CSE-M73G does not include built-in termination resistors. Add external 120Ω termination resistors at both ends of your RS-485 bus as needed.\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eQ: Is the module pin-compatible with CSE-M73 and CSE-M73A?\u003c\/span\u003e\u003cbr\u003eA: Yes, physically pin-compatible with the same footprint and connector layout. However, there are functional differences due to different MCUs. Always test CSE-M73G in your application before using as a drop-in replacement. Firmware is NOT interchangeable.\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eQ: Does the CSE-M73G support IPv6?\u003c\/span\u003e\u003cbr\u003eA: Yes! Full IPv4\/IPv6 dual stack support with both stateless (SLAAC) and stateful (DHCPv6) address auto-configuration. It's fully ready for modern IPv6 networks.\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eQ: How many devices can connect to the module simultaneously?\u003c\/span\u003e\u003cbr\u003eA: Up to 8 TCP clients can connect simultaneously. All connected clients receive the same serial data, perfect for distributed monitoring applications.\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eQ: What is the maximum baud rate?\u003c\/span\u003e\u003cbr\u003eA: Up to 230.4 kbps for all serial interfaces (RS-232, RS-422, RS-485, and 3.3V UART).\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eQ: How do I configure the module?\u003c\/span\u003e\u003cbr\u003eA: Three methods: (1) ezManager via Ethernet (easiest), (2) ezManager via serial port in Serial Configuration mode, (3) AT commands via serial terminal. Choose the method that works best for your development workflow.\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eQ: What are the default settings?\u003c\/span\u003e\u003cbr\u003eA: Default IP: 10.1.0.1, Subnet: 255.0.0.0, Port: 1470, Mode: TCP Server, Serial: RS-232, 19200 bps, 8-N-1. These can be changed via ezManager.\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eQ: Can I use this in outdoor applications?\u003c\/span\u003e\u003cbr\u003eA: The module is rated for industrial temperatures (-40°C to +85°C) but is not waterproof. For outdoor use, install in a weatherproof enclosure with proper sealing and environmental protection.\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eQ: What security features are included?\u003c\/span\u003e\u003cbr\u003eA: TLS v1.2 encryption, IP\/MAC address filtering, password-protected configuration, and secure firmware updates. This provides enterprise-grade security for sensitive applications.\u003c\/p\u003e\n\u003chr class=\"my-7 border-neutral-300 dark:border-neutral-700\"\u003e\n\u003ch2\u003e\u003cspan class=\"italic\"\u003eTechnical Support \u0026amp; Resources\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003ca title=\"CSE-M73G \/ Serial Ethernet Module\" href=\"https:\/\/www.eztcp.com\/en\/products\/cse-m73g\" target=\"_blank\"\u003e\u003cstrong\u003eCSE-M73G Embedded Serial Ethernet Module with RJ45 Product Page\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.eztcp.com\/en\/download\/utility.php\" target=\"_blank\"\u003e\u003cstrong\u003eEZTCP Utility Downloads\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.eztcp.com\/en\/download\/pds_files\/ds_csem73gen.pdf\" target=\"_blank\" title=\"CSE-M73G Embedded Serial to Ethernet Module with RJ45 Datasheet\" rel=\"noopener\"\u003e\u003cstrong\u003eCSE-M73G Embedded Serial to Ethernet Module Datasheet\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.eztcp.com\/en\/download\/pds_files\/csem73gen.pdf\" target=\"_blank\" title=\"CSE-M73G Embedded Serial to Ethernet Module with RJ45 User Manual\" rel=\"noopener\"\u003e\u003cstrong\u003eCSE-M73G Embedded Serial to Ethernet Module User Manual\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch3\u003eVideos\u003c\/h3\u003e\n\u003cp\u003eCSE-M73 Serial Ethernet Module\u003c\/p\u003e\n\u003cp\u003e\u003ciframe width=\"560\" height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/z5Mf3QQQwC8\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003chr class=\"my-7 border-neutral-300 dark:border-neutral-700\"\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cem class=\"italic\"\u003eProduct specifications subject to change without notice. Please verify compatibility with your specific application before production. Sollae Systems and ezTCP are registered trademarks of Sollae Systems Co., Ltd. All product names and trademarks are the property of their respective owners.\u003c\/em\u003e\u003c\/p\u003e","brand":"Sollae Systems","offers":[{"title":"Default Title","offer_id":43724556828921,"sku":"CSE-M73G-BO","price":69.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1641\/0911\/products\/serial-rs232-rs422-rs485-to-ethernet-network-module-eztcp-cse-m73g-632729.jpg?v=1677904833"},{"product_id":"industrial-2-port-serial-rs232-to-ethernet-network-device-server-eztcp-cse-h21","title":"Sollae Systems CSE-H21 Industrial 2-Port Serial RS-232 to Ethernet Converter","description":"\u003cp class=\"mb-2 mt-4 break-words text-xl font-semibold\"\u003eProfessional Dual-Port Serial Networking with IPv4\/IPv6 and Enhanced Security: \u003cspan class=\"font-semibold\"\u003eTransform two RS-232 serial devices into network-ready equipment with industrial-grade reliability, isolated ports, and advanced IPv6 support.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eThe Sollae Systems CSE-H21 is an industrial-grade 2-port RS-232 to Ethernet converter designed for demanding environments requiring multiple serial device connectivity. With support for both IPv4 and IPv6, electronically isolated serial ports, industrial temperature range (-40°C to +70°C), durable steel enclosure, and advanced security features including SSL\/TLS and SSH, the CSE-H21 delivers enterprise-level performance for mission-critical applications.\u003c\/p\u003e\n\u003chr class=\"my-7 border-neutral-300 dark:border-neutral-700\"\u003e\n\u003ch2 class=\"mb-2 mt-4 break-words text-xl font-semibold\"\u003eWhy Choose the CSE-H21?\u003c\/h2\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e🔌\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eDual RS-232 Ports\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eTwo independent RS-232 ports in one compact device. Connect two serial devices to your network with a single converter, reducing hardware costs and simplifying installations.\u003c\/p\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e🛡️\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eElectronically Isolated Ports\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eEach serial port is electronically isolated from the others and from the Ethernet port. This isolation provides superior noise immunity and prevents ground loops in industrial environments.\u003c\/p\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e🏗️\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eIndustrial Steel Enclosure\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eDurable steel case provides superior EMI shielding and physical protection compared to plastic housings. Built for harsh industrial environments where reliability is critical.\u003c\/p\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e🌐\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eFuture-Proof IPv6 Support\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eFull IPv4\/IPv6 dual stack implementation with stateless and stateful (DHCPv6) address auto-configuration. Ready for modern networks and future IPv6 deployments.\u003c\/p\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e🔒\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eAdvanced Security\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eMultiple security layers including SSL 3.0\/TLS 1.0, SSH 2.0, IP\/MAC filtering, and password protection. Enterprise-grade security for sensitive industrial control applications.\u003c\/p\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e🏭\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eIndustrial-Grade Reliability\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eOperating temperature range of -40°C to +70°C and robust design make this converter perfect for harsh industrial environments where consumer-grade equipment fails.\u003c\/p\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e🔄\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eMultiple Connection Support\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eMonitor and control from multiple locations simultaneously. Multiple clients can connect to each serial port for distributed monitoring and control applications (firmware v2.3A or later).\u003c\/p\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e⚡\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eHigh-Speed Performance\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eRS-232 support up to 230.4 kbps on each port ensures fast, reliable data transfer for even the most demanding serial applications.\u003c\/p\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e🎯\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eFlexible Configuration\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eConfigure via Ethernet (ezManager), serial port, AT commands, or Telnet. Choose the method that works best for your deployment scenario.\u003c\/p\u003e\n\u003chr class=\"my-7 border-neutral-300 dark:border-neutral-700\"\u003e\n\u003ch2 class=\"mb-2 mt-4 break-words text-xl font-semibold\"\u003eCSE-H21 Technical Specifications\u003c\/h2\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003eSerial Interface\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003ePhysical Interface:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003ePorts:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e2 x RS-232 (DB9 Male connectors)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eIsolation:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eElectronically isolated from each other and from Ethernet\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eSignals (per port):\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eRXD, TXD, GND, RTS, CTS, DTR, DSR\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eMaximum Baud Rate:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e230.4 kbps (per port)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eSupported Baud Rates:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e300, 600, 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200, 230400 bps\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eSerial Parameters (per port):\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eData Bits:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e8 bits, 7 bits (with parity)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eParity:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eNone, Even, Odd, Mark, Space\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eStop Bits:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e1, 1.5, 2\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eFlow Control:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eNone, RTS\/CTS, XON\/XOFF\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003ePin Assignment (DB9 Male, per port):\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003ePin 2:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eRXD (Receive Data) - Input\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003ePin 3:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eTXD (Transmit Data) - Output\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003ePin 4:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eDTR (Data Terminal Ready) - Output (Active during TCP connection)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003ePin 5:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eGND (Ground)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003ePin 6:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eDSR (Data Set Ready) - Input\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003ePin 7:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eRTS (Request To Send) - Output\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003ePin 8:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eCTS (Clear To Send) - Input\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eNote:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eWhen Data Bits is set to 7, NONE parity cannot be used.\u003c\/p\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003eNetwork Interface\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eEthernet:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003ePort:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e1 x RJ-45 (10\/100 Mbps)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eSpeed:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e10Base-T or 100Base-TX (Auto-Sensing)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eCable Detection:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eAuto MDI\/MDIX (works with straight or crossover cables)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eConnector LEDs:\u003c\/span\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eGreen: Link status (On = connected, Blink = data activity)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eYellow: Speed indicator (Off = 10Mbps, On = 100Mbps)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eNetwork Protocols:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eIPv4:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eTCP, UDP, IP, ICMP, ARP, DHCP, PPPoE, DNS, DDNS\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eIPv6:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eICMPv6, TCPv6, UDPv6, IPv6 fragmentation\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eIPv6 Configuration:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eStateless and Stateful (DHCPv6) auto-configuration\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eSecurity:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eSSL 3.0\/TLS 1.0, SSH 2.0\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eManagement:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eTelnet, HTTP (ezManager)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eAdvanced:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eTelnet COM Port Control Option (RFC 2217)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003eCommunication Modes (per port)\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eTCP Server (T2S):\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003ePassive connection mode\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eWaits for incoming TCP client connections\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eDefault local ports: 1470 (Port 1), 1471 (Port 2)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eIdeal for centralized monitoring applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eTCP Client (COD):\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eActive connection mode\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eInitiates connection to remote TCP server\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eConfigurable peer IP address and port\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003ePerfect for data logging and cloud integration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eAT Command Mode (ATC):\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eControl connections dynamically via AT commands\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eBoth active and passive connections supported\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eAllows runtime configuration changes\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003ePatented Sollae Systems technology\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eUDP Mode (U2S):\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eConnectionless communication\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eBroadcast and multicast support\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eLow-latency data transfer\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eN:M topology (many-to-many communication)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003ePower Specifications\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eInput Voltage:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eDC 5V ±0.5V (±10%)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eCurrent Consumption:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e300mA typical\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003ePower Connector:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eDC jack (Outer: Ø3.5mm, Inner: Ø1.35mm)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eProtection:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eOver-current, reverse voltage, and surge protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003eEnvironmental Specifications\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eOperating Temperature:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e-40°C to +70°C (-40°F to 158°F)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eStorage Temperature:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e-40°C to +85°C\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eHumidity:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e5% to 95% RH, non-condensing\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eCertifications:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eKC, CE, FCC Class A, RoHS compliant\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003ePhysical Specifications\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eDimensions:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e158mm (W) x 90mm (L) x 24mm (H) (6.22\" x 3.54\" x 0.94\")\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eWeight:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eApproximately 250g (8.82 oz)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eMounting:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eDesktop or DIN-rail mountable (optional bracket)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eEnclosure:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eIndustrial-grade steel case with EMI shielding\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003eStatus Indicators (LEDs)\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eTop Panel LEDs:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003ePWR (Red):\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003ePower indicator (On = power supplied)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eSTS (Yellow):\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eStatus indicator\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eBlinks every second = Obtaining IP address\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eBlinks 4 times = No IP address (DHCP\/PPPoE failure)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eOn = TCP connection established (either port)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eOff = ISP mode\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSimultaneous blink with LINK\/RXD\/TXD = Serial Configuration mode\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eLINK (Green):\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eEthernet link status (On = connected)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eRXD (Yellow):\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eEthernet receive activity (Blinks = receiving data)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eTXD (Green):\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eEthernet transmit activity (Blinks = transmitting data)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eFront Panel LEDs (per port):\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eSerial RXD (Yellow):\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eSerial receive activity\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eSerial TXD (Green):\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eSerial transmit activity\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr class=\"my-7 border-neutral-300 dark:border-neutral-700\"\u003e\n\u003ch2 class=\"mb-2 mt-4 break-words text-xl font-semibold\"\u003eReal-World Applications\u003c\/h2\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e🏭\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eIndustrial Automation \u0026amp; SCADA\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eConnect multiple PLCs, RTUs, and industrial controllers to SCADA systems\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eDual-port design reduces hardware costs for multi-device installations\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eRemote monitoring and control of manufacturing equipment\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eBuilding automation and energy management\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eFactory floor data collection from multiple sources\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eProcess control and monitoring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e💻\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eIT Infrastructure \u0026amp; Data Centers\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eSerial console servers for network equipment\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eOut-of-band management for servers and switches\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eKVM over IP applications\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eNetwork equipment management\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eServer room monitoring (UPS, environmental sensors)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eDual-device monitoring from single converter\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e📡\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eTelecommunications\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eSerial console access to multiple network devices\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eRemote management of telecom infrastructure\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eBase station monitoring and control\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eNetwork operations center (NOC) equipment\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eMulti-device equipment racks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e🏥\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eHealthcare \u0026amp; Medical Equipment\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eNetwork legacy diagnostic equipment and patient monitors\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eLaboratory automation and LIMS integration\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eMedical imaging device connectivity\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eHospital infrastructure management\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eDual medical device networking\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e🚂\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eTransportation \u0026amp; Infrastructure\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eRailway signaling and control systems\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eTraffic management and ITS applications\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eAirport ground support equipment\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eParking management and access control\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eFleet management systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e⚡\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eEnergy \u0026amp; Utilities\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eSmart grid monitoring and control\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSubstation automation\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eRemote meter reading (AMR\/AMI)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003ePower distribution management\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eEnvironmental monitoring stations\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eDual-device power monitoring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e🔬\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eLaboratory \u0026amp; Research\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eNetwork analytical instruments and data loggers\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eAutomated testing equipment\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eQuality control systems\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eResearch data acquisition\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eMulti-instrument connectivity\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e🏗️\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eSecurity \u0026amp; Access Control\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eCard readers and access control panels\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eCCTV camera control (PTZ)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eIntrusion detection systems\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eFire alarm panels\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eDual-device security monitoring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003eThe CSE-H21 RS232 to Ethernet Network Device Server can be used in diverse applications such as:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca style=\"font-size: 0.875rem;\" title=\"RS-232 control of signboards and other advertising and signage systems\" href=\"https:\/\/www.eztcp.com\/en\/applications\/internet-signboard\" target=\"_blank\"\u003eAdvertisement and Signage Systems\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca style=\"font-size: 0.875rem;\" title=\"RS-232 Serial control of Remote Weather Monitoring Stations\" href=\"https:\/\/www.eztcp.com\/en\/applications\/air-observation\" target=\"_blank\"\u003eRemote Weather Monitoring Systems\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca style=\"font-size: 0.875rem;\" title=\"Control PLC Over The Internet\" href=\"https:\/\/www.eztcp.com\/en\/applications\/plc-control\" target=\"_blank\"\u003eControl PLC over Internet\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr class=\"my-7 border-neutral-300 dark:border-neutral-700\"\u003e\n\u003ch2 class=\"mb-2 mt-4 break-words text-xl font-semibold\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e✓\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eCSE-H21 2-Port RS-232 to Ethernet Converter\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e(1 unit)\u003cbr\u003e✓\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eQuick Start Guide\u003c\/span\u003e\u003cbr\u003e✓\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eSoftware available for download:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eezManager (Configuration utility for Windows)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eezVSP (Virtual Serial Port driver for Windows)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eezTerm (TCP\/IP communication test tool)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eUser manual (PDF)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eDatasheet (PDF)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cem class=\"italic\"\u003eAll software is available for download from the Sollae Systems ezTCP website. See the link under the \u003cstrong\u003eTechnical Support \u0026amp; Resources\u003c\/strong\u003e section below.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eOptional Accessories\u003c\/h3\u003e\n\u003cp\u003e\u003ca rel=\"noopener\" title=\"AC\/DC WALL MOUNT ADAPTER 5V 5W W\/ 2.1MM X 5.5MM DC OUTPUT CONNECTOR\" href=\"https:\/\/envistiamall.com\/products\/ac-dc-wall-mount-adapter-5v-5w-dc-power-connector\" target=\"_blank\"\u003e+5V AC\/DC Wall Mount Power Supply\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca rel=\"noopener\" title=\"ezTCP Mounter and Bracket Assembly for DIN Mounting\" href=\"https:\/\/envistiamall.com\/products\/eztcp-mounter-and-bracket-assembly\" target=\"_blank\"\u003eMOUNTER and BRACKET Pair for mounting with DIN Rails\u003c\/a\u003e \u003c\/p\u003e\n\u003chr class=\"my-7 border-neutral-300 dark:border-neutral-700\"\u003e\n\u003ch2 class=\"mb-2 mt-4 break-words text-xl font-semibold\"\u003eQuick Setup Guide\u003c\/h2\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eStep 1: Physical Connections\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eConnect your first RS-232 device to Port 1 (DB9 Male)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eConnect your second RS-232 device to Port 2 (DB9 Male)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eConnect Ethernet cable to your network (straight or crossover - auto-detected)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eConnect 5V DC power adapter\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003ePWR LED will illuminate when powered on\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eStep 2: Network Configuration\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eDefault Settings:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eIP Address:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e10.1.0.1\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eSubnet Mask:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e255.0.0.0\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003ePort 1 Local Port:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e1470\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003ePort 2 Local Port:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e1471\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eCommunication Mode:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eTCP Server (both ports)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eBaud Rate:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e19,200 bps (both ports)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eData Format:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e8-N-1 (8 data bits, No parity, 1 stop bit)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cstrong\u003e\u003cspan class=\"font-semibold\"\u003eConfiguration Methods:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cstrong\u003e\u003cspan class=\"font-semibold\"\u003eOption A - ezManager via Ethernet (Recommended):\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003col class=\"ml-8 list-outside list-decimal\"\u003e\n\u003cli class=\"py-0.5\"\u003eDownload and run ezManager (no installation required)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eClick [MAC Address Search] or [IP Address Search] to discover CSE-H21\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSelect the device\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eConfigure network settings and parameters for each port independently\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eClick [Write] to save settings\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eDevice will reboot automatically\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cstrong\u003e\u003cspan class=\"font-semibold\"\u003eOption B - Serial Configuration:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003col class=\"ml-8 list-outside list-decimal\"\u003e\n\u003cli class=\"py-0.5\"\u003ePress function button for 1-3 seconds to enter Serial Configuration mode\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eAll LEDs (STS, LINK, RXD, TXD) blink simultaneously\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eOpen ezManager, select [Serial] tab\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSelect COM port and click [Open]\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eClick [Read] to load current settings\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eModify parameters as needed\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eClick [Write] to save\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cstrong\u003e\u003cspan class=\"font-semibold\"\u003eOption C - AT Commands:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003col class=\"ml-8 list-outside list-decimal\"\u003e\n\u003cli class=\"py-0.5\"\u003eSet communication mode to \"AT Command\" via ezManager\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eConnect via serial terminal (matching baud rate, 8-N-1)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eUse AT commands to configure parameters\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSave with AT+PWP command\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eStep 3: Configure Each Port Independently\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eEach serial port can be configured with different settings:\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003ePort 1:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eConfigure IP port, baud rate, data format, communication mode\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003ePort 2:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eConfigure IP port, baud rate, data format, communication mode\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003ePorts operate independently and simultaneously\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eStep 4: Test Communication\u003c\/span\u003e\u003c\/h3\u003e\n\u003col class=\"ml-8 list-outside list-decimal\"\u003e\n\u003cli class=\"py-0.5\"\u003eUse ezManager's [Simple Test] feature for each port\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eConfigure TCP connection (IP address and port)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eOpen serial port with matching parameters\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSend test data in both directions to verify operation\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eTotal setup time: 10-15 minutes\u003c\/span\u003e\u003c\/p\u003e\n\u003chr class=\"my-7 border-neutral-300 dark:border-neutral-700\"\u003e\n\u003ch2 class=\"mb-2 mt-4 break-words text-xl font-semibold\"\u003eAdvanced Features \u0026amp; Capabilities\u003c\/h2\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eDual Independent Ports\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eComplete Independence:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eEach port operates completely independently\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eDifferent baud rates, data formats, and communication modes per port\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSimultaneous operation of both ports\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eNo performance degradation when both ports active\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eFlexible Configuration:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003ePort 1:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eTCP Server at 9600 bps for PLC monitoring\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003ePort 2:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eTCP Client at 115200 bps for data logging\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eMix and match modes and settings as needed\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eUse Cases:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eMonitor two different devices simultaneously\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eOne port for production, one for development\/testing\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eDifferent protocols on each port\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eRedundant monitoring with different configurations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eElectronic Isolation\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eSuperior Noise Immunity:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eEach serial port is electronically isolated\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eIsolation between serial ports and Ethernet port\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003ePrevents ground loops in industrial environments\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eProtects against voltage spikes and surges\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eBenefits:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eImproved reliability in electrically noisy environments\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eProtection against ground potential differences\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eReduced electromagnetic interference (EMI)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eEnhanced system stability\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eIPv6 Dual Stack Implementation\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eThe CSE-H21 is fully IPv6-ready with comprehensive support:\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eIPv6 Features:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eFull IPv4\/IPv6 dual stack operation\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eStateless address auto-configuration (SLAAC)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eStateful address configuration (DHCPv6)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eIPv6 fragmentation support\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eICMPv6, TCPv6, UDPv6 protocols\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSeamless IPv4\/IPv6 interoperability\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eWhy IPv6 Matters:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eFuture-proof your infrastructure\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eLarger address space eliminates NAT complexity\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eImproved security with IPsec integration\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eBetter support for IoT devices\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSimplified network configuration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eMultiple Connection Support\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eSimultaneous Monitoring (Firmware v2.3A+):\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eMultiple TCP clients can connect to each port simultaneously\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003ePerfect for distributed monitoring applications\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eEach client receives the same serial data\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eIdeal for redundant monitoring systems\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eNo additional hardware required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eUse Cases:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eMultiple operators monitoring the same equipment\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eRedundant data logging systems\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eDistributed SCADA architectures\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eMulti-site monitoring applications\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eBackup monitoring stations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eEnhanced Security\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eSSL 3.0\/TLS 1.0:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eEncrypt serial data over the network\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eProtect sensitive information in transit\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eIndustry-standard encryption protocols\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eCertificate-based authentication\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003ePrevents eavesdropping and tampering\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eSSH 2.0:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eSecure shell protocol support\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eEncrypted remote access\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eStrong authentication mechanisms\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSecure configuration and management\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eAdditional Security Features:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eIP address filtering (whitelist\/blacklist)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eMAC address filtering\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003ePassword-protected configuration\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSecure firmware updates\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eAccess control lists\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003ePacket Fragmentation Control\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eSeparator Settings:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eDefine custom packet delimiters per port\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eControl when data is transmitted over network\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eOptimize for different protocols and applications\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eReduce network overhead\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eImprove application-level parsing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eData Frame Interval:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eConfigure timeout for packet assembly\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eBalance real-time performance vs. network efficiency\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eAdjustable from 0ms (immediate) to custom values\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eOptimize for your specific application\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eTelnet COM Port Control (RFC 2217)\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eRemote Serial Port Control:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eChange serial parameters remotely over network\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eAdjust baud rate, parity, data bits, stop bits\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eControl flow control settings\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eMonitor serial port status\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eNo physical access required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eBenefits:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eRemote troubleshooting and diagnostics\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eDynamic serial parameter adjustment\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eCentralized serial port management\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eReduced site visits and maintenance costs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eDynamic DNS (DDNS) Support\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eAlways Accessible:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eAutomatic DNS updates when IP address changes\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eUse hostname instead of IP address\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003ePerfect for dynamic IP environments\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSupports major DDNS providers\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSimplified remote access\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003ePPPoE Support\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eDirect Internet Connection:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eConnect directly to DSL\/cable modems\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eNo router required for simple deployments\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eAutomatic authentication and connection\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eIdeal for remote installations\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eReduced hardware costs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eAT Command Mode\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003ePatented Dynamic Control:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eChange connection parameters at runtime\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eEstablish\/terminate connections via serial commands\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eNo device reboot required\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003ePerfect for applications requiring dynamic connectivity\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eUnique Sollae Systems technology\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eAT Command Capabilities:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eConfigure IP addresses and ports\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eEstablish TCP connections\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eControl DHCP and PPPoE\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSet DNS servers\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eModify timeout values\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSave settings to flash memory\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr class=\"my-7 border-neutral-300 dark:border-neutral-700\"\u003e\n\u003ch2 class=\"mb-2 mt-4 break-words text-xl font-semibold\"\u003eSoftware Suite\u003c\/h2\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eezManager - Configuration Utility\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eComprehensive Management Tool for Windows:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eFeatures:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eNo installation required (portable application)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eAutomatic device discovery via MAC or IP address\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eIntuitive graphical interface\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eReal-time status monitoring for both ports\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eFirmware update management\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eConfiguration backup and restore\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSimple test utility included\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eBatch configuration for multiple devices\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eIndependent configuration for each port\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eConfiguration Methods:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eVia Ethernet (LAN)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eVia Serial port (either port)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eRemote configuration via Telnet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eezVSP - Virtual Serial Port Driver\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eWindows Virtual COM Port Driver:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eFeatures:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eCreates virtual COM ports on Windows PC\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eLegacy applications work without modification\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSupports multiple virtual ports (one per physical port)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eAutomatic reconnection on network interruption\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eCompatible with Windows 7\/8\/10\/11\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eNo application changes required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eHow It Works:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eEach CSE-H21 port appears as a local COM port on your Windows PC. Your existing serial software communicates with the virtual port, and ezVSP handles all network communication transparently.\u003c\/p\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eezTerm - Communication Test Tool\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eSimple TCP\/IP Testing:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eFeatures:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eQuick TCP\/IP communication testing\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eBoth TCP and UDP support\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eServer and client modes\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eHex and ASCII data display\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eData logging capabilities\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003ePerfect for troubleshooting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eSmartphone Applications\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eMobile Configuration:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eezManager app available for iOS and Android\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eConfigure devices from your smartphone or tablet\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eMonitor status remotely\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003ePerfect for field installations\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eFree download from app stores\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr class=\"my-7 border-neutral-300 dark:border-neutral-700\"\u003e\n\u003ch2 class=\"mb-2 mt-4 break-words text-xl font-semibold\"\u003eOperation Modes\u003c\/h2\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eNormal Mode\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eStandard Operation:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eFor normal data communication\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eFour communication modes available per port (TCP Server, TCP Client, AT Command, UDP)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eConfiguration via ezManager or Telnet\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eReal-time status monitoring\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eDefault operating mode\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eSerial Configuration Mode\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eSerial Port Configuration:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eConfigure via either RS-232 port\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSerial parameters: 115,200 bps, 8-N-1\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eUse ezManager Serial tab\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eNo network connection required\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003ePerfect for initial setup or network troubleshooting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eHow to Enter:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003ePress function button for 1-3 seconds\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eAll LEDs (STS, LINK, RXD, TXD) blink simultaneously\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eConnect via serial port at 115,200 bps\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eISP Mode (In-System Programming)\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eFirmware Updates:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eFor upgrading firmware\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eBypass security settings (password recovery)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eDirect firmware upload via ezManager\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eFactory reset capability\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eEmergency recovery mode\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eHow to Enter:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003ePress function button for more than 3 seconds during power-on\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSTS LED turns off\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eUpload firmware via ezManager\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr class=\"my-7 border-neutral-300 dark:border-neutral-700\"\u003e\n\u003ch2 class=\"mb-2 mt-4 break-words text-xl font-semibold\"\u003eNetwork Topology Examples\u003c\/h2\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eDual Device Monitoring\u003c\/span\u003e\u003c\/h3\u003e\n\u003cdiv class=\"my-4 w-full max-w-full overflow-hidden\"\u003e\n\u003cdiv class=\"code-block group relative my-1 rounded-[18px] overflow-hidden bg-muted\"\u003e\n\u003cdiv class=\"flex items-center justify-between px-3 py-2 bg-[#f5f5f7]\"\u003e\n\u003cdiv class=\"font-mono text-[11px] capitalize text-muted-foreground\"\u003e[Network Switch] ←→ [CSE-H21] ←→ Port 1 → [Serial Device A]\u003cbr\u003e                              ←→ Port 2 → [Serial Device B]\u003cbr\u003e                 ←→ [PC 1]\u003cbr\u003e                 ←→ [PC 2]\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eMultiple PCs access two serial devices over local network.\u003c\/p\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eMixed Mode Operation\u003c\/span\u003e\u003c\/h3\u003e\n\u003cdiv class=\"my-4 w-full max-w-full overflow-hidden\"\u003e\n\u003cdiv class=\"code-block group relative my-1 rounded-[18px] overflow-hidden bg-muted\"\u003e\n\u003cdiv class=\"flex items-center justify-between px-3 py-2 bg-[#f5f5f7]\"\u003e\n\u003cdiv class=\"font-mono text-[11px] capitalize text-muted-foreground\"\u003e[CSE-H21] ←→ Port 1 (TCP Server) → [PLC] ← Monitored by multiple clients\u003cbr\u003e          ←→ Port 2 (TCP Client) → [Data Logger] → Sends to cloud server\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eDifferent communication modes on each port for different applications.\u003c\/p\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eSerial Console Server\u003c\/span\u003e\u003c\/h3\u003e\n\u003cdiv class=\"my-4 w-full max-w-full overflow-hidden\"\u003e\n\u003cdiv class=\"code-block group relative my-1 rounded-[18px] overflow-hidden bg-muted\"\u003e\n\u003cdiv class=\"flex items-center justify-between px-3 py-2 bg-[#f5f5f7]\"\u003e\n\u003cdiv class=\"font-mono text-[11px] capitalize text-muted-foreground\"\u003e[Network] ←→ [CSE-H21] ←→ Port 1 → [Router Console]\u003cbr\u003e                       ←→ Port 2 → [Switch Console]\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eOut-of-band management for network equipment.\u003c\/p\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eRedundant Monitoring\u003c\/span\u003e\u003c\/h3\u003e\n\u003cdiv class=\"my-4 w-full max-w-full overflow-hidden\"\u003e\n\u003cdiv class=\"code-block group relative my-1 rounded-[18px] overflow-hidden bg-muted\"\u003e\n\u003cdiv class=\"flex items-center justify-between px-3 py-2 bg-[#f5f5f7]\"\u003e\n\u003cdiv class=\"font-mono text-[11px] capitalize text-muted-foreground\"\u003e                    ←→ [Monitor PC 1]\u003cbr\u003e[CSE-H21 Port 1] ←→ [Network] ←→ [Monitor PC 2]\u003cbr\u003e                    ←→ [Monitor PC 3]\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eMultiple clients simultaneously monitor one serial device (firmware v2.3A+).\u003c\/p\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eInternet Access via Router\u003c\/span\u003e\u003c\/h3\u003e\n\u003cdiv class=\"my-4 w-full max-w-full overflow-hidden\"\u003e\n\u003cdiv class=\"code-block group relative my-1 rounded-[18px] overflow-hidden bg-muted\"\u003e\n\u003cdiv class=\"flex items-center justify-between px-3 py-2 bg-[#f5f5f7]\"\u003e\n\u003cdiv class=\"font-mono text-[11px] capitalize text-muted-foreground\"\u003e[Internet] ←→ [Router] ←→ [CSE-H21] ←→ Port 1 → [Device A]\u003cbr\u003e                                    ←→ Port 2 → [Device B]\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eRemote access to both serial devices from anywhere in the world.\u003c\/p\u003e\n\u003chr class=\"my-7 border-neutral-300 dark:border-neutral-700\"\u003e\n\u003ch2 class=\"mb-2 mt-4 break-words text-xl font-semibold\"\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eQ: What's the difference between the CSE-H21 and the CSE-H53N?\u003c\/span\u003e\u003cbr\u003eA: The CSE-H21 has 2 RS-232 ports (vs 1 on CSE-H53N), electronically isolated ports, a steel enclosure (vs plastic), and slightly different operating temperature range (-40°C to +70°C vs -40°C to +85°C). The CSE-H21 is ideal when you need to connect two serial devices with one converter.\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eQ: Can each port be configured independently?\u003c\/span\u003e\u003cbr\u003eA: Yes! Each port has completely independent configuration. You can set different baud rates, data formats, communication modes, and network ports for each serial port. They operate simultaneously without interference.\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eQ: What does \"electronically isolated\" mean?\u003c\/span\u003e\u003cbr\u003eA: Electronic isolation means each serial port is electrically separated from the other port and from the Ethernet port. This prevents ground loops, reduces noise interference, and protects against voltage spikes. It's essential for reliable operation in industrial environments.\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eQ: Can I use both ports simultaneously?\u003c\/span\u003e\u003cbr\u003eA: Yes! Both ports operate completely independently and simultaneously. There's no performance degradation when both ports are active. You can have different devices on each port with different configurations.\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eQ: Does the CSE-H21 support IPv6?\u003c\/span\u003e\u003cbr\u003eA: Yes! The CSE-H21 has full IPv4\/IPv6 dual stack support with both stateless (SLAAC) and stateful (DHCPv6) address auto-configuration. It's fully ready for modern IPv6 networks.\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eQ: Can multiple computers access each serial port simultaneously?\u003c\/span\u003e\u003cbr\u003eA: Yes, with firmware version 2.3A or later, multiple TCP clients can connect to each port simultaneously. All connected clients receive the same serial data, perfect for distributed monitoring applications.\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eQ: What security features does the CSE-H21 have?\u003c\/span\u003e\u003cbr\u003eA: The CSE-H21 includes SSL 3.0\/TLS 1.0 encryption, SSH 2.0, IP\/MAC filtering, and password-protected configuration. This provides enterprise-grade security for sensitive industrial control applications.\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eQ: What is AT Command mode?\u003c\/span\u003e\u003cbr\u003eA: AT Command mode is a patented Sollae Systems feature that allows you to control TCP\/IP connections dynamically via serial AT commands. You can establish connections, change IP addresses, modify ports, and configure network parameters without rebooting the device.\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eQ: How do I configure the CSE-H21?\u003c\/span\u003e\u003cbr\u003eA: You have multiple options: (1) ezManager via Ethernet, (2) ezManager via serial port, (3) AT commands via serial terminal, or (4) Telnet. Choose the method that works best for your deployment.\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eQ: What are the default settings?\u003c\/span\u003e\u003cbr\u003eA: Default IP address is 10.1.0.1 with subnet mask 255.0.0.0. Port 1 uses local port 1470, Port 2 uses 1471. Both ports default to TCP Server mode, 19,200 bps, 8-N-1 data format.\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eQ: Can I use this outdoors?\u003c\/span\u003e\u003cbr\u003eA: The CSE-H21 is rated for industrial temperatures (-40°C to +70°C) but is not waterproof. For outdoor use, install in a weatherproof enclosure (NEMA 4X or IP65 rated).\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eQ: What operating systems are supported?\u003c\/span\u003e\u003cbr\u003eA: The device works with any OS that supports TCP\/IP (Windows, Linux, macOS, Unix, etc.). The ezManager and ezVSP utilities are Windows-only, but you can configure via Telnet or AT commands from any platform.\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eQ: Can I mount this on a DIN rail?\u003c\/span\u003e\u003cbr\u003eA: Yes, the CSE-H21 supports DIN-rail mounting with an optional mounting bracket (sold separately).\u003c\/p\u003e\n\u003chr class=\"my-7 border-neutral-300 dark:border-neutral-700\"\u003e\n\u003ch2\u003e\u003cspan class=\"italic\"\u003eTechnical Support \u0026amp; Resources\u003c\/span\u003e\u003c\/h2\u003e\n\u003cdiv\u003e\u003ca href=\"https:\/\/www.eztcp.com\/en\/products\/cse-h21\" title=\"EZTCP CSE-H21 Industrial 2-Port RS232 Ethernet Device Server Web Page\" rel=\"noopener\" target=\"_blank\"\u003e\u003cstrong\u003eCSE-H21 Industrial 2-Port RS232 Ethernet Device Server Product Page\u003c\/strong\u003e\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ca href=\"https:\/\/www.eztcp.com\/en\/download\/pds_files\/ds_cseh21en.pdf\" title=\"CSE-H21 Industrial 2-Port Serial RS-232 to Ethernet Network Device Server PDF Datasheet\" rel=\"noopener\" target=\"_blank\"\u003e\u003cstrong\u003eCSE-H21 \u003c\/strong\u003e\u003c\/a\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/www.eztcp.com\/en\/products\/cse-h21\" title=\"EZTCP CSE-H21 Industrial 2-Port RS232 Ethernet Device Server Web Page\" rel=\"noopener\" target=\"_blank\"\u003eIndustrial 2-Port RS232 Ethernet Device Server\u003c\/a\u003e Datasheet (PDF)\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/www.eztcp.com\/en\/download\/pds_files\/cseh21en.pdf\" target=\"_blank\" title=\"CSE-H21 2 Port Industrial RS232 Serial to Ethernet Converter User Manual\" rel=\"noopener\"\u003eCSE-H21 Industrial 2-Port RS232 Ethernet Device Server User Manual (PDF)\u003c\/a\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003ca href=\"https:\/\/www.eztcp.com\/en\/download\/utility.php\" title=\"EZTCP Utility Downloads\" rel=\"noopener\" target=\"_blank\"\u003e\u003cstrong\u003eEZTCP Utility Downloads\u003c\/strong\u003e\u003c\/a\u003e\u003c\/div\u003e\n\u003ch3\u003e\n\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003eVideos\u003c\/h3\u003e\n\u003cp\u003eIndustrial 2-Port RS232 to Ethernet Device Server | CSE-H21\u003c\/p\u003e\n\u003cp\u003e\u003ciframe title=\"YouTube video player\" src=\"https:\/\/www.youtube.com\/embed\/7HsMzQCMiNY?si=IaLmIDkDgMdqXMeX\" height=\"315\" width=\"560\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003cp\u003eezTCP Serial Networking Introductory video\u003c\/p\u003e\n\u003cp\u003e\u003ciframe title=\"YouTube video player\" src=\"https:\/\/www.youtube.com\/embed\/m9DIY6r245Y\" height=\"315\" width=\"560\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e","brand":"Sollae Systems","offers":[{"title":"Default Title","offer_id":44530303533305,"sku":"CSE-H21-BO","price":192.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1641\/0911\/products\/industrial-2-port-serial-rs232-to-ethernet-network-device-server-eztcp-cse-h21-206223.jpg?v=1710432180"},{"product_id":"cse-m53g-eztcp-embedded-serial-to-ethernet-module","title":"Sollae Systems ezTCP CSE-M53G Embedded Serial to Ethernet Module RS232\/RS422\/RS485","description":"\u003cp class=\"mb-2 mt-4 break-words text-xl font-semibold\"\u003eUltra-Compact OEM Module for Embedded Serial Networking: \u003cspan class=\"font-semibold\"\u003eIntegrate professional-grade serial-to-Ethernet connectivity directly into your products with this super-compact 20mm x 24mm embedded module.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eThe Sollae Systems CSE-M53G is an industrial-grade embedded serial-to-Ethernet module designed for OEM integration into equipment, instruments, and devices. With its ultra-compact footprint (20mm x 24mm), pin-compatible design with CSE-M53\/M53N, and support for both IPv4 and IPv6, the CSE-M53G delivers enterprise-level networking performance in a tiny package perfect for space-constrained embedded applications.\u003c\/p\u003e\n\u003chr class=\"my-7 border-neutral-300 dark:border-neutral-700\"\u003e\n\u003ch2 class=\"mb-2 mt-4 break-words text-xl font-semibold\"\u003eWhy Choose the CSE-M53G?\u003c\/h2\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e📦\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eUltra-Compact Design\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eAt just 20mm x 24mm x 9.1mm and weighing only 3.2g, the CSE-M53G is one of the smallest serial-to-Ethernet modules available. Perfect for embedding directly into your products where space is at a premium.\u003c\/p\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e🔌\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003ePin-Compatible with CSE-M53\/M53N\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eDrop-in compatible design allows easy migration from CSE-M53 or CSE-M53N modules. Standardize on one footprint across your product line while leveraging the latest features.\u003c\/p\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e🌐\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eFuture-Proof IPv6 Support\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eFull IPv4\/IPv6 dual stack implementation with stateless and stateful (DHCPv6) address auto-configuration. Ready for modern networks and future IPv6 deployments.\u003c\/p\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e🏭\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eIndustrial-Grade Reliability\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eExtreme temperature range (-40°C to +85°C) and robust design make this module perfect for harsh industrial environments where consumer-grade components fail.\u003c\/p\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e🔒\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eEnhanced Security\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eBuilt-in TLS v1.2 encryption, IP\/MAC filtering, and password protection ensure your serial data remains secure across the network.\u003c\/p\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e🔄\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eMultiple Connection Support\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eMonitor and control from multiple locations simultaneously. Multiple clients can connect to a single CSE-M53G for distributed monitoring and control applications (firmware v2.3A or later).\u003c\/p\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e⚡\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eHigh-Speed Performance\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eUART support up to 921.6 kbps (under certain conditions) ensures fast, reliable data transfer for even the most demanding serial applications.\u003c\/p\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e🎯\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eFlexible Serial Interface\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eSingle UART can be configured for RS-232, RS-422, or RS-485 operation with simple external circuitry. One module handles all your serial interface needs.\u003c\/p\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e🛠️\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eEasy Integration\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eSimple 2mm pitch pin headers, comprehensive documentation, reference circuit designs, and free configuration software make integration straightforward.\u003c\/p\u003e\n\u003chr class=\"my-7 border-neutral-300 dark:border-neutral-700\"\u003e\n\u003ch2 class=\"mb-2 mt-4 break-words text-xl font-semibold\"\u003eCSE-M53G Technical Specifications\u003c\/h2\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003eSerial Interface\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003ePhysical Interface:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eType:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e1 x UART (3.3V level with 5V tolerant input)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eSignals:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eRXD, TXD, RTS (TXDE for RS-485), CTS, GND\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eConnector:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e2 x 10-pin headers (2mm pitch)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eSerial Modes:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eRS-232:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e300 to 921,600 bps (without XON\/XOFF)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eRS-232 with XON\/XOFF:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e300 to 230,400 bps\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eRS-422\/RS-485:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e300 to 230,400 bps\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eWith SSL\/TLS:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e300 to 115,200 bps\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eSerial Parameters:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eData Bits:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e8 bits, 7 bits (with parity)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eParity:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eNone, Even, Odd, Mark, Space\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eStop Bits:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e1, 2\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eFlow Control:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eNone, RTS\/CTS, XON\/XOFF\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eNote:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e7 data bits with NONE parity is not supported\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eA single idle bit is automatically added after every stop bit by the MCU function\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003eNetwork Interface\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eEthernet:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eSpeed:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e10Base-T or 100Base-TX (Auto-Sensing)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eCable Detection:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eAuto MDI\/MDIX (works with straight or crossover cables)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eConnection:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eSimple external circuit required (pulse transformer in RJ-45)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eNetwork Protocols:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eIPv4:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eTCP, UDP, IP, ICMP, ARP, DHCP, PPPoE, DNS, DDNS, Telnet\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eIPv6:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eICMPv6, TCPv6, UDPv6, IPv6 fragmentation\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eIPv6 Configuration:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eStateless and Stateful (DHCPv6) auto-configuration\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eSecurity:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eTLS v1.2 (Secure Socket Layer)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eAdvanced:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eTelnet COM Port Control Option (RFC 2217)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003eCommunication Modes\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eTCP Server (T2S):\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003ePassive connection mode\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eWaits for incoming TCP client connections\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eDefault local port: 1470\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eIdeal for centralized monitoring applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eTCP Client (COD):\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eActive connection mode\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eInitiates connection to remote TCP server\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eConfigurable peer IP address and port\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003ePerfect for data logging and cloud integration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eAT Command Mode (ATC):\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eControl connections dynamically via AT commands\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eBoth active and passive connections supported\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eAllows runtime configuration changes\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003ePatented Sollae Systems technology\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eUDP Mode (U2S):\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eConnectionless communication\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eBroadcast and multicast support\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eLow-latency data transfer\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eN:M topology (many-to-many communication)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003ePower Specifications\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eInput Voltage:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eDC 3.3V ±0.3V (±10%)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eCurrent Consumption:\u003c\/span\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e100M Ethernet: 110mA typical\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e10M Ethernet: 150mA typical\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003ePower Filtering:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eFilter interface recommended for 3.3V power input\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003eEnvironmental Specifications\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eOperating Temperature:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e-40°C to +85°C (-40°F to 185°F)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eStorage Temperature:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e-40°C to +85°C\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eHumidity:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e5% to 95% RH, non-condensing\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eCertifications:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eRoHS compliant\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003ePhysical Specifications\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eDimensions:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e20mm (W) x 24mm (L) x 9.1mm (H) (0.79\" x 0.94\" x 0.36\")\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eWeight:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eApproximately 3.2g (0.11 oz)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eMounting:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eSurface mount via pin headers\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003ePCB Recommendation:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e4-layer PCB recommended to reduce noise\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003ePin Configuration\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eJP1 Connector (10 pins, 2mm pitch):\u003c\/span\u003e\u003c\/p\u003e\n\u003col class=\"ml-8 list-outside list-decimal\"\u003e\n\u003cli class=\"py-0.5\"\u003eGND - Ground\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eTP_RXN - LAN IN - (Input)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eTP_RXP - LAN IN + (Input)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eGND - Ground\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eTP_TXN - LAN OUT - (Output)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eTP_TXP - LAN OUT + (Output)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eGND - Ground\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eRXD_LED - LAN Receive LED (Active Low)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eTXD_LED - LAN Transmit LED (Active Low)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eLINK_LED - Link LED (Active Low)\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eJP2 Connector (10 pins, 2mm pitch):\u003c\/span\u003e\u003c\/p\u003e\n\u003col class=\"ml-8 list-outside list-decimal\"\u003e\n\u003cli class=\"py-0.5\"\u003eVDD_3.3V - DC 3.3V ±0.3V power\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eRST- - System Reset (Active Low, \u0026gt;200μs recommended)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eISP- - Mode selection\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eGND - Ground\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eRXD - UART IN (Input)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eTXD - UART OUT (Output)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eCTS - UART CTS (Input)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eRTS - UART RTS (Output) \/ TXDE for RS-485\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eTCP - TCP Status LED (Active Low)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSTS_LED - Status LED (varies by mode)\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003eStatus LED Indicators\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eSTS_LED Operation:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eISP Mode:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eSolid ON\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eSerial Configuration Mode:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eBlinking (250ms period)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eNo IP Address:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eFast blink pattern (125ms\/1000ms)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eIP Assigned, No TCP Connection:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eBlinking (500ms period)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eTCP Connected:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eSolid ON\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr class=\"my-7 border-neutral-300 dark:border-neutral-700\"\u003e\n\u003ch2 class=\"mb-2 mt-4 break-words text-xl font-semibold\"\u003eReal-World Applications\u003c\/h2\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e🏭\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eIndustrial Equipment OEM Integration\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eEmbed networking into PLCs, controllers, and industrial instruments\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eFactory automation equipment\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eProcess control devices\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eManufacturing machinery\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eIndustrial sensors and actuators\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e🔬\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eMedical \u0026amp; Laboratory Equipment\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eDiagnostic equipment networking\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eLaboratory instruments\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eMedical imaging devices\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003ePatient monitoring systems\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eAnalytical equipment\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e🏗️\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eBuilding Automation\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eHVAC controllers\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eLighting control systems\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eAccess control panels\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eFire alarm systems\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eEnergy management devices\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e⚡\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eEnergy \u0026amp; Utilities\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eSmart meters\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003ePower monitoring devices\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSubstation equipment\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSolar inverters\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eBattery management systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e🚗\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eTransportation \u0026amp; Automotive\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eVehicle telematics\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eFleet management devices\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eParking systems\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eTraffic control equipment\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eRailway signaling\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e📡\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eTelecommunications\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eNetwork equipment\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eBase station controllers\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eTelecom infrastructure\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eRemote monitoring devices\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e🎮\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eConsumer Electronics\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eGaming peripherals\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eHome automation devices\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSmart appliances\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eIoT devices\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eEntertainment systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e🔧\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eTest \u0026amp; Measurement\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eOscilloscopes\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eData loggers\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eEnvironmental monitors\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eQuality control equipment\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eCalibration devices\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe CSE-M53G is ideal for various environments such as:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.eztcp.com\/en\/applications\/rfid-system\" title=\"RFID Systems\" rel=\"noopener\" target=\"_blank\"\u003e\u003cem\u003eRFID Systems\u003c\/em\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.eztcp.com\/en\/applications\/remote-monitoring\" title=\"Remote Monitoring Using Serial Communication to Ethernet\" rel=\"noopener\" target=\"_blank\"\u003e\u003cem\u003eRemote Monitoring Systems\u003c\/em\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.eztcp.com\/en\/applications\/serial-tunneling\" title=\"Serial Tunneling\" rel=\"noopener\" target=\"_blank\"\u003eE\u003cem\u003extending distance between two devices through the LAN (Serial Tunneling)\u003c\/em\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr class=\"my-7 border-neutral-300 dark:border-neutral-700\"\u003e\n\u003ch2 class=\"mb-2 mt-4 break-words text-xl font-semibold\"\u003eWhat's Included\u003c\/h2\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e✓\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eCSE-M53G Serial to Ethernet Module\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e(1 unit)\u003cbr\u003e✓\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eDocumentation:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eUser Manual (PDF)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eDatasheet (PDF)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eReference circuit designs\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eIntegration guide\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e✓\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eSoftware available for download:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eezManager (Configuration utility for Windows)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eezVSP (Virtual Serial Port driver for Windows)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eezTerm (TCP\/IP communication test tool)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cem class=\"italic\"\u003eAll software is available for download from the Sollae Systems ezTCP website. See the link under the \u003cstrong\u003eTechnical Support \u0026amp; Resources\u003c\/strong\u003e section below.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"italic\"\u003e\u003cstrong\u003eNOTE: \u003c\/strong\u003eThis device is a module, requiring an interface board to provide the mounting and interface.  The \u003cstrong\u003e\u003ca title=\"EVB-M53G Evaluation Board for the CSE-M53G Serial to Ethernet Module\" href=\"https:\/\/envistiamall.com\/products\/evb-m53g-evaluation-board-for-cse-m53g-eztcp-embedded-serial-to-ethernet-module\"\u003eEVB-M53G evaluation board\u003c\/a\u003e\u003c\/strong\u003e, which can be purchased separately, has been developed for testing the CSE-M53G module before users design their own interface board. The evaluation board provides many interfaces including a DC jack, a serial port that is selectable for both RS232 and RS485, and an RJ45 for network connectivity.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cstrong\u003e\u003cspan class=\"font-semibold\"\u003eNote:\u003c\/span\u003e This is an OEM module.\u003c\/strong\u003e External components (not included) are required for complete implementation (RJ-45 connector with pulse transformer, power supply, RS-232\/422\/485 interface circuitry).\u003c\/p\u003e\n\u003chr class=\"my-7 border-neutral-300 dark:border-neutral-700\"\u003e\n\u003ch2 class=\"mb-2 mt-4 break-words text-xl font-semibold\"\u003eIntegration Guide\u003c\/h2\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eStep 1: PCB Design\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003ePCB Recommendations:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eUse 4-layer PCB to reduce noise\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eKeep Ethernet traces as short as possible\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eImplement proper ground planes\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eFollow reference circuit design in datasheet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eRequired External Components:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eRJ-45 connector with integrated pulse transformer\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e3.3V power supply with filtering\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSeries resistor on RST- signal (recommended)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eEMC capacitors (C2-C5 in reference circuit)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eRS-232\/422\/485 interface circuitry (as needed)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eStep 2: Hardware Connection\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003ePower:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eConnect regulated 3.3V ±0.3V to VDD_3.3V (JP2 pin 1)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eImplement power filtering as shown in reference circuit\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eConnect all GND pins\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eEthernet:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eConnect TP_RXP\/RXN and TP_TXP\/TXN to RJ-45 pulse transformer\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eFollow reference circuit for proper magnetics\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eImplement EMC protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eSerial Interface:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eConnect RXD, TXD, RTS, CTS to your serial interface circuitry\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eAdd RS-232 level shifters (e.g., MAX3232) for RS-232 operation\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eAdd RS-422\/485 transceivers for RS-422\/485 operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eStep 3: Initial Configuration\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eDefault Settings:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eIP Address:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e10.1.0.1\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eSubnet Mask:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e255.0.0.0\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eLocal Port:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e1470\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eCommunication Mode:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eTCP Server\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eSerial Type:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eRS-232\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eBaud Rate:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e19,200 bps\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eData Format:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e8-N-1 (8 data bits, No parity, 1 stop bit)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eConfiguration Methods:\u003c\/span\u003e\u003c\/p\u003e\n\u003col class=\"ml-8 list-outside list-decimal\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eVia Ethernet:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eUse ezManager to discover and configure\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eVia Serial:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eEnter Serial Configuration mode (ISP- LOW \u0026lt; 1 second)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eAT Commands:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eSet communication mode to AT Command and use serial terminal\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eStep 4: Testing\u003c\/span\u003e\u003c\/h3\u003e\n\u003col class=\"ml-8 list-outside list-decimal\"\u003e\n\u003cli class=\"py-0.5\"\u003ePower on the module\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eVerify LED indicators (LINK_LED, STS_LED)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eUse ezManager to discover module on network\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eConfigure network and serial parameters\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eTest data communication using ezTerm or Simple Test feature\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eVerify bidirectional data flow\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eTotal integration time: 2-4 hours (experienced engineers)\u003c\/span\u003e\u003c\/p\u003e\n\u003chr class=\"my-7 border-neutral-300 dark:border-neutral-700\"\u003e\n\u003ch2 class=\"mb-2 mt-4 break-words text-xl font-semibold\"\u003eAdvanced Features \u0026amp; Capabilities\u003c\/h2\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eIPv6 Dual Stack Implementation\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eThe CSE-M53G is fully IPv6-ready with comprehensive support:\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eIPv6 Features:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eFull IPv4\/IPv6 dual stack operation\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eStateless address auto-configuration (SLAAC)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eStateful address configuration (DHCPv6)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eIPv6 fragmentation support\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eICMPv6, TCPv6, UDPv6 protocols\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSeamless IPv4\/IPv6 interoperability\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eWhy IPv6 Matters for OEM Products:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eFuture-proof your product line\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eLarger address space for IoT deployments\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eImproved security with IPsec integration\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eBetter support for mobile and distributed devices\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSimplified network configuration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eMultiple Connection Support\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eSimultaneous Monitoring (Firmware v2.3A+):\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eMultiple TCP clients can connect to one CSE-M53G simultaneously\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003ePerfect for distributed monitoring applications\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eEach client receives the same serial data\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eIdeal for redundant monitoring systems\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eNo additional hardware required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eUse Cases:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eMultiple operators monitoring the same equipment\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eRedundant data logging systems\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eDistributed SCADA architectures\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eMulti-site monitoring applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eTLS v1.2 Security\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eSecure Socket Layer Protection:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eEncrypt serial data over the network\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eProtect sensitive information in transit\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eIndustry-standard TLS v1.2 protocol\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eCertificate-based authentication\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003ePrevents eavesdropping and tampering\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eSecurity Features:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eIP address filtering (whitelist\/blacklist)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eMAC address filtering\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003ePassword-protected configuration\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSecure firmware updates\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eAccess control lists\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003ePacket Fragmentation Control\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eSeparator Settings:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eDefine custom packet delimiters\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eControl when data is transmitted over network\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eOptimize for different protocols and applications\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eReduce network overhead\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eImprove application-level parsing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eData Frame Interval:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eConfigure timeout for packet assembly\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eBalance real-time performance vs. network efficiency\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eAdjustable from 0ms (immediate) to custom values\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eOptimize for your specific application\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eTelnet COM Port Control (RFC 2217)\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eRemote Serial Port Control:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eChange serial parameters remotely over network\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eAdjust baud rate, parity, data bits, stop bits\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eControl flow control settings\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eMonitor serial port status\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eNo physical access required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eBenefits:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eRemote troubleshooting and diagnostics\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eDynamic serial parameter adjustment\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eCentralized serial port management\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eReduced field service costs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eDynamic DNS (DDNS) Support\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eAlways Accessible:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eAutomatic DNS updates when IP address changes\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eUse hostname instead of IP address\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003ePerfect for dynamic IP environments\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSupports major DDNS providers\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSimplified remote access\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003ePPPoE Support\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eDirect Internet Connection:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eConnect directly to DSL\/cable modems\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eNo router required for simple deployments\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eAutomatic authentication and connection\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eIdeal for remote installations\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eReduced hardware costs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eAT Command Mode\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003ePatented Dynamic Control:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eChange connection parameters at runtime\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eEstablish\/terminate connections via serial commands\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eNo device reboot required\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003ePerfect for applications requiring dynamic connectivity\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eUnique Sollae Systems technology\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eAT Command Capabilities:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eConfigure IP addresses and ports\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eEstablish TCP connections\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eControl DHCP and PPPoE\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSet DNS servers\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eModify timeout values\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSave settings to flash memory\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr class=\"my-7 border-neutral-300 dark:border-neutral-700\"\u003e\n\u003ch2 class=\"mb-2 mt-4 break-words text-xl font-semibold\"\u003eSoftware Suite\u003c\/h2\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eezManager - Configuration Utility\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eComprehensive Management Tool for Windows:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eFeatures:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eNo installation required (portable application)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eAutomatic device discovery via MAC or IP address\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eIntuitive graphical interface\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eReal-time status monitoring\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eFirmware update management\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eConfiguration backup and restore\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSimple test utility included\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eBatch configuration for multiple devices\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eConfiguration Methods:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eVia Ethernet (LAN)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eVia Serial port\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eRemote configuration via Telnet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eezVSP - Virtual Serial Port Driver\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eWindows Virtual COM Port Driver:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eFeatures:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eCreates virtual COM ports on Windows PC\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eLegacy applications work without modification\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSupports multiple virtual ports\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eAutomatic reconnection on network interruption\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eCompatible with Windows 7\/8\/10\/11\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eNo application changes required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eHow It Works:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eThe CSE-M53G appears as a local COM port on your Windows PC. Your existing serial software communicates with the virtual port, and ezVSP handles all network communication transparently.\u003c\/p\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eezTerm - Communication Test Tool\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eSimple TCP\/IP Testing:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eFeatures:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eQuick TCP\/IP communication testing\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eBoth TCP and UDP support\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eServer and client modes\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eHex and ASCII data display\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eData logging capabilities\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003ePerfect for troubleshooting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr class=\"my-7 border-neutral-300 dark:border-neutral-700\"\u003e\n\u003ch2 class=\"mb-2 mt-4 break-words text-xl font-semibold\"\u003eOperation Modes\u003c\/h2\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eNormal Mode\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eStandard Operation:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eFor normal data communication\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eFour communication modes available (TCP Server, TCP Client, AT Command, UDP)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eConfiguration via ezManager or Telnet\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eReal-time status monitoring\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eDefault operating mode\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eSerial Configuration Mode\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eSerial Port Configuration:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eConfigure via UART port\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSerial parameters: 115,200 bps, 8-N-1\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eUse ezManager Serial tab\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eNo network connection required\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003ePerfect for initial setup or network troubleshooting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eHow to Enter:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eConnect ISP- pin to GND (LOW) for less than 1 second\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSTS_LED blinks at 250ms period\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eConnect via serial port at 115,200 bps\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eISP Mode (In-System Programming)\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eFirmware Updates:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eFor upgrading firmware\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eBypass security settings (password recovery)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eDirect firmware upload via ezManager\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eFactory reset capability\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eEmergency recovery mode\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eHow to Enter:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eConnect ISP- pin to GND (LOW) for more than 1 second during power-on\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSTS_LED turns solid ON\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eUpload firmware via ezManager\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr class=\"my-7 border-neutral-300 dark:border-neutral-700\"\u003e\n\u003ch2 class=\"mb-2 mt-4 break-words text-xl font-semibold\"\u003eDesign Considerations\u003c\/h2\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003ePCB Layout Best Practices\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eLayer Stack-up:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eUse 4-layer PCB minimum\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eLayer 1: Signal layer (components)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eLayer 2: Ground plane\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eLayer 3: Power plane (3.3V)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eLayer 4: Signal layer (routing)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eEthernet Routing:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eKeep differential pairs (TP_RXP\/RXN, TP_TXP\/TXN) matched in length\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eMaintain 100Ω differential impedance\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eRoute away from noisy signals\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eKeep traces as short as possible\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eUse ground plane for return path\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003ePower Supply:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eImplement LC or RC filter on 3.3V input\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003ePlace decoupling capacitors close to VDD pins\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eUse low-ESR capacitors (ceramic recommended)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSeparate analog and digital grounds if possible\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eEMC Considerations:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eAdd series resistors on Ethernet lines (reference circuit)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eImplement common-mode chokes\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eUse shielded RJ-45 connector\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eFollow EMC capacitor placement in reference design\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eThermal Management\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eHeat Dissipation:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eModule dissipates approximately 0.33W (100mA @ 3.3V)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eEnsure adequate airflow in enclosed designs\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eConsider thermal vias under module for heat spreading\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eMonitor junction temperature in high-ambient applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eOperating Temperature:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eModule rated for -40°C to +85°C ambient\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eDerate if enclosed without ventilation\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eConsider heat from adjacent components\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eReset Circuit\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eRST- Signal:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eActive LOW reset\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eMinimum pulse width: 200μs recommended\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eAdd series resistor (1kΩ typical) for protection\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eCan be driven by supervisor IC or microcontroller\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eNormally pulled HIGH, driven LOW to reset\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eMode Selection (ISP- Pin)\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eISP- Control:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003ePulled HIGH for Normal mode\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eLOW \u0026lt; 1 second: Serial Configuration mode\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eLOW \u0026amp;gt; 1 second during power-on: ISP mode\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eUse pull-up resistor (10kΩ typical)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eCan be controlled by microcontroller or jumper\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr class=\"my-7 border-neutral-300 dark:border-neutral-700\"\u003e\n\u003ch2 class=\"mb-2 mt-4 break-words text-xl font-semibold\"\u003ePin-Compatibility Notes\u003c\/h2\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eCSE-M53 vs CSE-M53N vs CSE-M53G\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003ePhysical Compatibility:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eAll three modules share the same pin-out\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSame 20mm x 24mm footprint\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSame 2mm pitch pin headers\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eDrop-in replacement possible\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eFunctional Differences:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eCSE-M53G:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eLatest generation, TLS v1.2, enhanced features\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eCSE-M53N:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003ePrevious generation, SSL 3.0\/TLS 1.0\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eCSE-M53:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eOriginal version, basic SSL\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eImportant:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eMCU functions differ between versions\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eFirmware is NOT interchangeable\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eTest compatibility thoroughly before substitution\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSome timing characteristics may vary\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eConsult datasheets for specific differences\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eMigration Recommendations:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eTest CSE-M53G in your application before mass production\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eVerify all features work as expected\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eUpdate firmware to latest version\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eReview any application-specific timing requirements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr class=\"my-7 border-neutral-300 dark:border-neutral-700\"\u003e\n\u003ch2 class=\"mb-2 mt-4 break-words text-xl font-semibold\"\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eQ: What's the difference between CSE-M53G and the standalone CSE-H53N converter?\u003c\/span\u003e\u003cbr\u003eA: The CSE-M53G is an OEM module for embedding into your products (20mm x 24mm, requires external components). The CSE-H53N is a complete standalone converter with enclosure, connectors, and power adapter. Choose CSE-M53G for OEM integration, CSE-H53N for standalone applications.\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eQ: What's the difference between CSE-M53G and CSE-M73G?\u003c\/span\u003e\u003cbr\u003eA: The CSE-M73G includes an integrated RJ-45 connector and built-in RS-232\/422\/485 interface circuitry (64.3 x 40 x 17mm, 17g). The CSE-M53G requires external Ethernet components and serial interface circuitry (20 x 24 x 9.1mm, 3.2g). Choose CSE-M73G for easier integration with ready-to-use Ethernet and serial interfaces, CSE-M53G for smallest possible footprint.\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eQ: What external components are required?\u003c\/span\u003e\u003cbr\u003eA: You need: (1) RJ-45 connector with integrated pulse transformer, (2) 3.3V regulated power supply, (3) RS-232\/422\/485 interface circuitry (level shifters or transceivers), (4) EMC components (capacitors, resistors per reference circuit), (5) Reset circuit (optional).\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eQ: Can I use this module with RS-485?\u003c\/span\u003e\u003cbr\u003eA: Yes! The UART can be configured for RS-485 operation. You'll need to add an external RS-485 transceiver IC (e.g., MAX485, SN75176). The RTS pin becomes TXDE (transmit data enable) in RS-485 mode for automatic direction control.\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eQ: Is the module pin-compatible with CSE-M53 and CSE-M53N?\u003c\/span\u003e\u003cbr\u003eA: Yes, physically pin-compatible with the same footprint. However, there are functional differences due to different MCUs. Always test CSE-M53G in your application before using as a drop-in replacement. Firmware is NOT interchangeable.\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eQ: What PCB design is recommended?\u003c\/span\u003e\u003cbr\u003eA: Use a 4-layer PCB minimum to reduce noise. Follow the reference circuit design in the datasheet. Keep Ethernet traces short and matched. Implement proper ground planes. Use EMC components as shown in reference design.\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eQ: Does the CSE-M53G support IPv6?\u003c\/span\u003e\u003cbr\u003eA: Yes! Full IPv4\/IPv6 dual stack support with both stateless (SLAAC) and stateful (DHCPv6) address auto-configuration. It's fully ready for modern IPv6 networks.\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eQ: Can multiple devices connect to the module simultaneously?\u003c\/span\u003e\u003cbr\u003eA: Yes, with firmware version 2.3A or later, multiple TCP clients can connect simultaneously. All connected clients receive the same serial data, perfect for distributed monitoring applications.\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eQ: What is the maximum baud rate?\u003c\/span\u003e\u003cbr\u003eA: Up to 921.6 kbps for RS-232 without XON\/XOFF flow control (under certain conditions). RS-422\/485 and RS-232 with XON\/XOFF support up to 230.4 kbps. When using SSL\/TLS, maximum is 115.2 kbps.\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eQ: How do I configure the module?\u003c\/span\u003e\u003cbr\u003eA: Three methods: (1) ezManager via Ethernet (easiest), (2) ezManager via serial port in Serial Configuration mode, (3) AT commands via serial terminal. Choose the method that works best for your development workflow.\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eQ: What are the default settings?\u003c\/span\u003e\u003cbr\u003eA: Default IP: 10.1.0.1, Subnet: 255.0.0.0, Port: 1470, Mode: TCP Server, Serial: RS-232, 19200 bps, 8-N-1. These can be changed via ezManager.\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eQ: Can I use this in outdoor applications?\u003c\/span\u003e\u003cbr\u003eA: The module is rated for industrial temperatures (-40°C to +85°C) but is not waterproof. For outdoor use, install in a weatherproof enclosure with proper sealing and environmental protection.\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eQ: What security features are included?\u003c\/span\u003e\u003cbr\u003eA: TLS v1.2 encryption, IP\/MAC address filtering, password-protected configuration, and secure firmware updates. This provides enterprise-grade security for sensitive applications.\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eQ: How do I update the firmware?\u003c\/span\u003e\u003cbr\u003eA: Enter ISP mode (ISP- pin LOW \u0026gt; 1 second during power-on), then use ezManager to upload new firmware. The process is straightforward and documented in the user manual.\u003c\/p\u003e\n\u003chr class=\"my-7 border-neutral-300 dark:border-neutral-700\"\u003e\n\u003ch2\u003e\u003cspan class=\"italic\"\u003eTechnical Support \u0026amp; Resources\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.eztcp.com\/en\/products\/cse-m53g\" title=\"ezTCP CSE-M53G Product Page\" rel=\"noopener\" target=\"_blank\"\u003e\u003cstrong\u003eCSE-M53G Embedded Serial to Ethernet Module Product Page\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/www.eztcp.com\/en\/download\/utility.php\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eEZTCP Utility Downloads\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca rel=\"noopener\" title=\"CSE-M53G Embedded Serial to Ethernet Module Datasheet\" href=\"https:\/\/www.eztcp.com\/en\/download\/pds_files\/ds_csem53gen.pdf\" target=\"_blank\"\u003e\u003cstrong\u003eCSE-M53G Embedded Serial to Ethernet Module Datasheet\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca rel=\"noopener\" title=\"CSE-M53G Embedded Serial to Ethernet Module User Manual\" href=\"https:\/\/www.eztcp.com\/en\/download\/pds_files\/csem53gen.pdf\" target=\"_blank\"\u003e\u003cstrong\u003eCSE-M53G Embedded Serial to Ethernet Module User Manual\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch3\u003eVideos\u003c\/h3\u003e\n\u003cp\u003e\u003ciframe width=\"560\" height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/m9DIY6r245Y?si=rgEcslZ8XjhBQxIu\" title=\"YouTube video player\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003eSerial Networking Solutions | Serial to LAN\/WLAN\/Internet Converter Video\u003c\/p\u003e\n\u003chr class=\"my-7 border-neutral-300 dark:border-neutral-700\"\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cem class=\"italic\"\u003eProduct specifications subject to change without notice. Please verify compatibility with your specific application before production. Sollae Systems and ezTCP are registered trademarks of Sollae Systems Co., Ltd. All product names and trademarks are the property of their respective owners.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Sollae Systems","offers":[{"title":"Default Title","offer_id":45027405136121,"sku":"CSE-M53G-BO","price":39.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1641\/0911\/files\/cse-m53g-eztcp-embedded-serial-to-ethernet-module-331989.jpg?v=1715991202"},{"product_id":"evb-m53g-evaluation-board-for-cse-m53g-eztcp-embedded-serial-to-ethernet-module","title":"EVB-M53G Evaluation Board for CSE-M53G ezTCP Embedded Serial to Ethernet Module","description":"\u003cp\u003eThe EZTCP EVB-M53G is an Evaluation Board for the \u003ca title=\"CSE-M53G ezTCP Embedded Serial to Ethernet Module\" href=\"https:\/\/envistiamall.com\/products\/cse-m53g-eztcp-embedded-serial-to-ethernet-module\"\u003eCSE-M53G embedded serial to Ethernet module\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003eThe CSE-M53G is a compact module connect which connects a serial device to the Internet. This device is a module, so you need an interface board to provide the mounting and interface.  This evaluation board has been developed for testing the CSE-M53G module before users design their own interface board. The evaluation board provides many interfaces including a DC jack, a serial port that is selectable for both RS232 and RS485, and an RJ45 for network connectivity.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackage includes:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"padding-left: 30px;\"\u003e1X EVB-M53G Embedded Serial to Ethernet Module\u003cbr\u003eThe CSE-M53G is not included, and should be ordered separately\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNOTE\u003c\/strong\u003e: The CSE-M53G Serial to Ethernet Module is shown in the photos for illustrative purposes. It is not included with the EVB-M53G and should be ordered separately. \u003c\/p\u003e\n\u003ch4\u003eEVB-M53G Evaluation Board Specifications and Operating Manual (PDF)\u003c\/h4\u003e\n\u003cp\u003e\u003ciframe height=\"500\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1641\/0911\/files\/an_csem53g_evb_en.pdf?v=1715974861\" width=\"100%\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDelivery is stock to 2 weeks, if the item is out of stock, please contact us for availability.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Sollae Systems","offers":[{"title":"Default Title","offer_id":45027558097145,"sku":"EVB-M53G-BO","price":54.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1641\/0911\/files\/evb-m53g-evaluation-board-for-cse-m53g-eztcp-embedded-serial-to-ethernet-module-394602.jpg?v=1716322614"},{"product_id":"systembase-cslan-rs232-serial-to-ethernet-converter","title":"SystemBase CS-LAN RS-232 Serial to Ethernet Converter","description":"\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eInstantly connect RS-232 serial devices to your Ethernet network—no programming required.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eThe SystemBase CS-LAN is your professional-grade solution for bridging the gap between legacy serial equipment and modern IP networks. Whether you're managing industrial automation systems, point-of-sale terminals, or laboratory instruments, this compact converter delivers reliable plug-and-play connectivity.\u003c\/p\u003e\n\u003chr class=\"my-7 border-neutral-300 dark:border-neutral-700\"\u003e\n\u003ch2 class=\"mb-2 mt-4 break-words text-xl font-semibold\"\u003eWhy Choose the CS-LAN?\u003c\/h2\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e🚀\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003ePlug-and-Play Simplicity\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eNo complex programming or driver installations. Configure everything through an intuitive web interface and get connected in minutes.\u003c\/p\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e💪\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eIndustrial-Grade Performance\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eBuilt to withstand harsh environments with an operating temperature range of -40°C to 85°C. Designed for 24\/7 continuous operation in demanding industrial settings.\u003c\/p\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e⚡\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eHigh-Speed Communication\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eSupport for baud rates up to 921.6 kbps ensures fast, reliable data transfer for even the most demanding applications.\u003c\/p\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e🔒\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eEnhanced Protection\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eBuilt-in 15kV IEC ESD protection safeguards your equipment from electrostatic discharge and power surges.\u003c\/p\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e💰\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eCost-Effective Solution\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eExtend the life of existing serial equipment without expensive hardware replacements. One affordable converter replaces costly system upgrades.\u003c\/p\u003e\n\u003chr class=\"my-7 border-neutral-300 dark:border-neutral-700\"\u003e\n\u003ch2 class=\"mb-2 mt-4 break-words text-xl font-semibold\"\u003eComplete Technical Specifications\u003c\/h2\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003eSerial Interface\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003ePort:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e1 x RS-232 (DB9 Male connector)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eMaximum Baud Rate:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e921.6 kbps\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eSupported Baud Rates:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e300, 600, 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200, 230400, 460800, 921600 bps\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eData Bits:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e5, 6, 7, 8\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eStop Bits:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e1, 1.5, 2\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eParity:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eNone, Even, Odd, Mark, Space\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eFlow Control:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eHardware (RTS\/CTS), Software (XON\/XOFF), None\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eSignals:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eTXD, RXD, RTS, CTS, DTR, DSR, DCD, GND\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003eNetwork Interface\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eEthernet Port:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e1 x 10\/100 Mbps Auto-MDIX (RJ-45)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eNetwork Protocols:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eTCP\/IP, UDP, ARP, ICMP, DHCP Client, DNS\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eOperating Modes:\u003c\/span\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eTCP Server (listen for incoming connections)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eTCP Client (connect to remote host)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eUDP (broadcast\/multicast support)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eIP Configuration:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eStatic IP or DHCP\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eConnection Management:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eMultiple simultaneous connections supported\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003eConfiguration \u0026amp; Management\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eSetup Methods:\u003c\/span\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eWeb-based configuration interface\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eTelnet console\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eWindows configuration utility (PortView)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eSoftware Included:\u003c\/span\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eCOM Port Redirector (Virtual COM Port driver)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003ePortView (Configuration utility)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eTestView (Testing and diagnostics)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eStatus Indicators:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eLED indicators for Power, Link\/Activity, Serial TX\/RX\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eSecurity:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003ePassword-protected configuration access\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003ePower \u0026amp; Protection\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003ePower Input:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e5V DC via included power adapter\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003ePower Consumption:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u0026lt; 2.5W (energy efficient)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eESD Protection:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eBuilt-in 15kV IEC ESD protection\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eSurge Protection:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eIntegrated protection circuitry\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003eEnvironmental Specifications\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eOperating Temperature:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e-40°C to 85°C (-40°F to 185°F) - Industrial grade\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eStorage Temperature:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e-40°C to 85°C\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eHumidity:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e5% to 95% RH, non-condensing\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eCertifications:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eCE, FCC, RoHS compliant\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003ePhysical Specifications\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eDimensions:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e85mm x 65mm x 25mm (3.35\" x 2.56\" x 0.98\")\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eWeight:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eApproximately 150g (5.3 oz)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eMounting:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eDesktop or DIN-rail mountable (optional bracket available)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eEnclosure:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eDurable industrial-grade plastic housing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr class=\"my-7 border-neutral-300 dark:border-neutral-700\"\u003e\n\u003ch2 class=\"mb-2 mt-4 break-words text-xl font-semibold\"\u003eReal-World Applications\u003c\/h2\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e🏭\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eIndustrial Automation \u0026amp; Manufacturing\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eConnect PLCs, motor controllers, and sensors to SCADA systems\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eRemote monitoring and control of production equipment\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eIntegration with building automation and energy management systems\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eFactory floor data collection and analysis\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e🏥\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eHealthcare \u0026amp; Medical Equipment\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eNetwork legacy diagnostic equipment and patient monitors\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eCentralize data from laboratory analyzers and testing equipment\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eRemote access to medical imaging devices\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eIntegration with hospital information systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e🏪\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eRetail \u0026amp; Point of Sale\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eConnect barcode scanners, receipt printers, and cash drawers\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eIntegrate legacy POS terminals with modern networks\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eCentralized management of multiple retail locations\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eInventory management and tracking systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e🔬\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eLaboratory \u0026amp; Research\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eNetwork analytical instruments and data loggers\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eRemote data collection from environmental sensors\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eIntegration with LIMS (Laboratory Information Management Systems)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eAutomated testing and quality control systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e📡\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eTelecommunications \u0026amp; Networking\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eSerial console access to routers, switches, and servers\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eRemote management of telecom infrastructure\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eNetwork monitoring and diagnostics\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eOut-of-band management solutions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e🚗\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eTransportation \u0026amp; Logistics\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eVehicle tracking and fleet management systems\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eWarehouse automation and inventory control\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eAccess control and security systems\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eParking management and toll collection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e⚡\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eEnergy \u0026amp; Utilities\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eSmart grid monitoring and control\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eRemote meter reading systems\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003ePower distribution monitoring\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eEnvironmental monitoring stations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr class=\"my-7 border-neutral-300 dark:border-neutral-700\"\u003e\n\u003ch2 class=\"mb-2 mt-4 break-words text-xl font-semibold\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e✓\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eCS-LAN Serial to Ethernet Converter\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e(1 unit)\u003cbr\u003e✓\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003e5V DC Power Adapter\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003ewith regional plug\u003cbr\u003e✓\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eQuick Start Guide\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003efor rapid deployment\u003cbr\u003e✓\u003cspan\u003e Ethernet cable\u003c\/span\u003e\u003cbr\u003e\u003cspan class=\"font-semibold\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cem class=\"italic\"\u003eAll software is available for download from the SystemBase website. See the link under the \u003cstrong\u003eTechnical Support \u0026amp; Resources\u003c\/strong\u003e section below.\u003c\/em\u003e\u003c\/p\u003e\n\u003chr class=\"my-7 border-neutral-300 dark:border-neutral-700\"\u003e\n\u003ch2 class=\"mb-2 mt-4 break-words text-xl font-semibold\"\u003eQuick \u0026amp; Easy Setup\u003c\/h2\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eStep 1: Physical Connection\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eConnect your RS-232 serial device to the DB9 port\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003ePlug in the Ethernet cable to your network\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eConnect the 5V DC power adapter\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eStep 2: Network Configuration\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eAccess the built-in web server from any browser\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSet your IP address (static or DHCP)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eConfigure serial port parameters (baud rate, data bits, etc.)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSelect operating mode (TCP Server, TCP Client, or UDP)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eStep 3: Start Communicating\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eYour serial device is now accessible over the network\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eUse TCP\/IP applications or install the Virtual COM Port driver\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eTest connectivity using the included TestView software\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eTotal setup time: Less than 5 minutes!\u003c\/span\u003e\u003c\/p\u003e\n\u003chr class=\"my-7 border-neutral-300 dark:border-neutral-700\"\u003e\n\u003ch2 class=\"mb-2 mt-4 break-words text-xl font-semibold\"\u003eAdvanced Features \u0026amp; Capabilities\u003c\/h2\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eVirtual COM Port Technology\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eThe included COM Port Redirector software creates a virtual COM port on your Windows PC, making the network connection appear as a local serial port. Your existing serial applications work without any modification!\u003c\/p\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eFlexible Operating Modes\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eTCP Server Mode:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eDevice listens for incoming connections\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eMultiple clients can connect simultaneously\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eIdeal for applications where multiple computers need to access one serial device\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eConfigurable connection limits and timeouts\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eTCP Client Mode:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eDevice initiates connection to a remote host\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003ePerfect for data logging and remote monitoring\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eAutomatic reconnection on network interruption\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eConfigurable retry intervals\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eUDP Mode:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eBroadcast or multicast data to multiple recipients\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eLow-latency communication\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eIdeal for real-time monitoring applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eIntelligent Data Handling\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eConfigurable packet timeout and size\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eData buffering for reliable transmission\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eAutomatic flow control management\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSupport for binary and ASCII data\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eNetwork Discovery\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eThe PortView configuration utility automatically discovers all CS-LAN devices on your network—no need to hunt for IP addresses or configure complex network settings.\u003c\/p\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eRemote Management\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eWeb-based configuration accessible from anywhere on the network\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eTelnet console for command-line management\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSNMP support for network monitoring integration\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eFirmware updates via network (no physical access required)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr class=\"my-7 border-neutral-300 dark:border-neutral-700\"\u003e\n\u003ch2 class=\"mb-2 mt-4 break-words text-xl font-semibold\"\u003eSoftware Suite\u003c\/h2\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eCOM Port Redirector\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eCreates virtual COM ports on Windows systems, allowing legacy serial applications to communicate over the network without modification. Supports Windows 7\/8\/10\/11.\u003c\/p\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003ePortView Configuration Utility\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eIntuitive Windows application for:\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eAutomatic device discovery\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eEasy configuration of network and serial parameters\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eFirmware updates\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eDevice monitoring and diagnostics\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eTestView Testing Software\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eComprehensive testing tool for:\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eSerial port communication testing\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eNetwork connectivity verification\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eData transmission monitoring\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eTroubleshooting and diagnostics\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr class=\"my-7 border-neutral-300 dark:border-neutral-700\"\u003e\n\u003ch2 class=\"mb-2 mt-4 break-words text-xl font-semibold\"\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eQ: What operating systems are supported?\u003c\/span\u003e\u003cbr\u003eA: The CS-LAN works with any operating system that supports TCP\/IP networking (Windows, Linux, macOS, Unix, etc.). The Virtual COM Port driver and configuration utilities are Windows-only, but the web interface works in any modern browser.\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eQ: Can multiple computers access the serial device at the same time?\u003c\/span\u003e\u003cbr\u003eA: Yes, in TCP Server mode, multiple clients can connect simultaneously. However, you can configure whether they share access or queue for exclusive access to prevent data conflicts.\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eQ: What's the maximum cable distance for RS-232?\u003c\/span\u003e\u003cbr\u003eA: Standard RS-232 supports up to 50 feet (15m). For longer distances, use high-quality shielded cable or consider RS-422\/485 converters which support distances up to 4,000 feet.\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eQ: Does it work with non-standard baud rates?\u003c\/span\u003e\u003cbr\u003eA: Yes, the CS-LAN supports standard and non-standard baud rates from 300 to 921,600 bps.\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eQ: Can I use this in outdoor or harsh environments?\u003c\/span\u003e\u003cbr\u003eA: The CS-LAN is rated for industrial temperatures (-40°C to 85°C) and can handle harsh environments. For outdoor use, ensure it's protected from direct water exposure (it's not waterproof).\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eQ: Does it support Power over Ethernet (PoE)?\u003c\/span\u003e\u003cbr\u003eA: No, the CS-LAN requires external 5V DC power. However, SystemBase offers the \u003ca rel=\"noopener\" title=\"SystemBase sLan\/all-POE POE Serial RS232 \/ RS422 \/ RS485 to Ethernet Converter\" href=\"https:\/\/envistiamall.com\/products\/poe-serial-rs232-rs422-rs485-to-ethernet-converter-slan-all\" target=\"_blank\"\u003esLAN\/All PoE\u003c\/a\u003e model if you need PoE capability.\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eQ: How do I update the firmware?\u003c\/span\u003e\u003cbr\u003eA: Firmware updates can be performed remotely via the web interface or PortView utility—no physical access required.\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eQ: What if my application requires RS-422 or RS-485?\u003c\/span\u003e\u003cbr\u003eA: The CS-LAN is RS-232 only. For RS-422\/485, check out our other \u003ca href=\"https:\/\/envistiamall.com\/collections\/serial-to-ethernet-converters\" title=\"RS232 RS422 and RS485 Serial to Ethernet Converters at Envistia Mall\" rel=\"noopener\" target=\"_blank\"\u003eSerial to Ethernet converters\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eQ: Is there a limit to data throughput?\u003c\/span\u003e\u003cbr\u003eA: The CS-LAN can handle continuous data streams at full baud rate (up to 921.6 kbps) with minimal latency, making it suitable for high-throughput applications.\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eQ: Can I monitor the connection status remotely?\u003c\/span\u003e\u003cbr\u003eA: Yes, the web interface provides real-time status monitoring, and the device supports SNMP for integration with network monitoring systems.\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eQ: Is PoE (Power over Ethernet) supported?\u003c\/span\u003e\u003cbr\u003eA: No, the CS-LAN requires external 5V DC power via the included adapter. For A PoE-powered Serial to Ethernet Converter, see the \u003ca rel=\"noopener\" title=\"SystemBase sLan\/all-POE POE Serial RS232 \/ RS422 \/ RS485 to Ethernet Converter\" href=\"https:\/\/envistiamall.com\/products\/poe-serial-rs232-rs422-rs485-to-ethernet-converter-slan-all\" target=\"_blank\"\u003eSystemBase sLAN\/All PoE\u003c\/a\u003e. \u003c\/p\u003e\n\u003chr class=\"my-7 border-neutral-300 dark:border-neutral-700\"\u003e\n\u003ch2 class=\"mb-2 mt-4 break-words text-xl font-semibold\"\u003eTechnical Support \u0026amp; Resources\u003c\/h2\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\u003ca rel=\"noopener\" title=\"SystemBase CS-LAN User Manual (PDF)\" href=\"https:\/\/envistia.com\/documents\/CS-LAN_UserManual_Eng.pdf\" target=\"_blank\"\u003eDownload the User Manual (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\u003ca rel=\"noopener\" title=\"SystemBase CS-LAN Software and Utilities Downloads\" href=\"https:\/\/www.sysbas.com\/en\/downloads\/cs-lan\/\" target=\"_blank\"\u003eDownload Configuration Software and Utilities (SystemBase Website)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eNeed help? Contact our technical support team at\u003cspan\u003e \u003c\/span\u003e\u003ca class=\"cursor-pointer break-words text-[#2964AA] hover:opacity-80 dark:text-[#7AB7FF]\" href=\"mailto:support@envistiamall.com\"\u003esupport@envistiamall.com\u003c\/a\u003e\u003c\/p\u003e","brand":"SystemBase","offers":[{"title":"Default Title","offer_id":47462606962937,"sku":"CS-LAN","price":189.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1641\/0911\/files\/systembase-cs-lan-rs-232-serial-to-ethernet-converter-9691862.jpg?v=1772363588"},{"product_id":"cse-b63g-embedded-rs232-rs485-serial-to-ethernet-module","title":"Sollae Systems CSE-B63G Industrial RS-232\/RS-485 Serial to Ethernet Module","description":"\u003cp\u003eThe Sollae Systems CSE-B63G is a professional board-type RS-232 and RS-485 serial-to-Ethernet module built around the proven ezTCP CSE-M53G module core. Designed for OEM integration and industrial applications, the CSE-B63G features integrated DB9-M serial connector and RJ-45 Ethernet connector mounted directly on the board, eliminating the need for additional circuitry and dramatically simplifying integration. With support for both RS-232 and RS-485 interfaces, IPv4\/IPv6 dual stack networking, industrial temperature range (-40°C to +85°C), and advanced security features including TLS v1.2, the CSE-B63G delivers enterprise-level performance in a compact 80mm x 45mm board format perfect for embedded applications, control panels, and harsh industrial environments.\u003c\/p\u003e\n\u003chr class=\"my-7 border-neutral-300 dark:border-neutral-700\"\u003e\n\u003ch2 class=\"mb-2 mt-4 break-words text-xl font-semibold\"\u003eWhy Choose the CSE-B63G?\u003c\/h2\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e🔄\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eDual Serial Interface Support\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eSingle module supports both RS-232 and RS-485 interfaces. Switch between interfaces based on your application needs without changing hardware—maximum flexibility for diverse deployment scenarios.\u003c\/p\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e🏭\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eIndustrial-Grade Reliability\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eExtreme temperature range (-40°C to +85°C) and robust design with reverse voltage and surge protection make this module perfect for harsh industrial environments where consumer-grade equipment fails.\u003c\/p\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e📦\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eCompact Board Design\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eAt just 80mm x 45mm x 17mm, the CSE-B63G provides a complete serial-to-Ethernet solution in a board format perfect for embedding directly into equipment, control panels, and industrial enclosures.\u003c\/p\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e🌐\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eFuture-Proof IPv6 Support\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eFull IPv4\/IPv6 dual stack implementation ensures compatibility with modern networks and future IPv6 deployments. Ready for today's infrastructure and tomorrow's requirements.\u003c\/p\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e🔒\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eEnhanced Security\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eBuilt-in TLS v1.2 encryption, IP\/MAC filtering, and password protection ensure your serial data remains secure across the network. Enterprise-grade security for industrial control applications.\u003c\/p\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e⚡\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eHigh-Speed Performance\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eUART support up to 921.6 kbps (under certain conditions) ensures fast, reliable data transfer for even the most demanding serial applications.\u003c\/p\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e🔌\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eBuilt-In RS-485 Features\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eIntegrated 3.9kΩ biasing resistors for RS-485 simplify installation and improve reliability. No external biasing components required.\u003c\/p\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e🎯\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eFlexible Configuration\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eConfigure via Ethernet (ezManager), Telnet, or AT commands. Choose the method that works best for your deployment scenario. Patented AT command mode allows dynamic runtime configuration.\u003c\/p\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e🛡️\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eProtection Circuitry\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eBuilt-in reverse voltage and surge protection safeguard the module from electrical transients and installation errors common in industrial environments.\u003c\/p\u003e\n\u003chr class=\"my-7 border-neutral-300 dark:border-neutral-700\"\u003e\n\u003ch2 class=\"mb-2 mt-4 break-words text-xl font-semibold\"\u003eCSE-B63G Technical Specifications\u003c\/h2\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003eSerial Interface\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003ePhysical Interfaces:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eRS-232:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eRXD, TXD, CTS, RTS, GND\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eRS-485:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eTRX+, TRX-, GND (with built-in 3.9kΩ biasing resistors)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eSerial Parameters:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eBaud Rate:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e300 to 921,600 bps (up to 921.6 kbps under certain conditions)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eData Bits:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e8 bits, 7 bits (with parity)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eParity:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eNone, Even, Odd, Mark, Space\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eStop Bits:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e1, 2\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eFlow Control:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eRTS\/CTS (RS-232)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eNote:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eA single idle bit is automatically added after every stop bit by the MCU function.\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eRS-485 Features:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eBuilt-in 3.9kΩ biasing resistors\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eHalf-duplex communication\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eMulti-drop network support\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eDifferential signaling for noise immunity\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003eNetwork Interface\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eEthernet:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003ePort:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eRJ-45 connector\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eSpeed:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e10Base-T or 100Base-TX (Auto-Sensing)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eCable Detection:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eAuto MDI\/MDIX (works with straight or crossover cables)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eNetwork Protocols:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eIPv4\/IPv6:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eDual stack support\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eIPv6 Protocols:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eICMPv6, TCPv6, UDPv6\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eIPv4 Protocols:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eTCP, UDP, IP, ICMP, ARP, Telnet\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eNetwork Services:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eDHCP, PPPoE, DNS, DDNS\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eSecurity:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eSSL\/TLS v1.2 (Secure Socket Layer)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003eCommunication Modes\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eTCP Server (T2S):\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003ePassive connection mode\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eWaits for incoming TCP client connections\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eIdeal for centralized monitoring applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eTCP Client (COD):\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eActive connection mode\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eInitiates connection to remote TCP server\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003ePerfect for data logging and cloud integration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eAT Command Mode (ATC) - Patented:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eControl connections dynamically via AT commands\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eBoth active and passive connections supported\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eAllows runtime configuration changes\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eUnique Sollae Systems technology\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eUDP Mode (U2S):\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eConnectionless communication\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eBroadcast and multicast support\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eLow-latency data transfer\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003eSecurity Features\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eTLS v1.2:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eSecure Socket Layer encryption\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eProtect sensitive data in transit\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eIndustry-standard security protocol\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eAccess Control:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eIP address filtering (whitelist\/blacklist)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eMAC address filtering\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eRestrict access to specific hosts or networks\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003ePassword-protected configuration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003eAdvanced Features\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003ePacket Fragmentation Control:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eSeparator settings for packet fragmentation\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eDefine custom packet delimiters\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eOptimize for different protocols and applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eAdditional Functions:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eTCP Server\/Client mode switching\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSending MAC address option\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eFlexible data handling\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003ePower Specifications\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eInput Voltage:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eDC 5V\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eCurrent Consumption:\u003c\/span\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e100M Ethernet: 133mA\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e10M Ethernet: 173mA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eProtection:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eReverse voltage and surge protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003eEnvironmental Specifications\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eOperating Temperature:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e-40°C to +85°C (-40°F to 185°F)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eStorage Temperature:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e-40°C to +85°C\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eHumidity:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e5% to 95% RH, non-condensing (typical for industrial modules)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003ePhysical Specifications\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eDimensions:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e80mm (W) x 45mm (L) x 17mm (H) (3.15\" x 1.77\" x 0.67\")\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eForm Factor:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eBoard-type module\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eMounting:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003ePCB mounting or panel mounting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003eStatus Indicators (LEDs)\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eSystem LEDs:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003ePWR:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003ePower indicator\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eLINK:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eEthernet link status\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eSTS:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eSystem status\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eTCP:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eTCP connection status\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eNetwork LEDs:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eTXD:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eNetwork transmit activity\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eRXD:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eNetwork receive activity\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eSerial LEDs:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eTXD:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eSerial transmit activity\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eRXD:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eSerial receive activity\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eRTS:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eRequest To Send status\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eCTS:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eClear To Send status\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr class=\"my-7 border-neutral-300 dark:border-neutral-700\"\u003e\n\u003ch2 class=\"mb-2 mt-4 break-words text-xl font-semibold\"\u003eReal-World Applications\u003c\/h2\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e🏭\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eIndustrial Automation \u0026amp; Control\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003ePLC networking and remote monitoring\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSCADA system integration\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eFactory automation equipment\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eProcess control devices\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eManufacturing machinery networking\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eIndustrial sensor networks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e⚡\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eEnergy \u0026amp; Utilities\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eSmart grid monitoring and control\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSubstation automation\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003ePower distribution management\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eRemote meter reading (AMR\/AMI)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSolar inverter monitoring\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eBattery management systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e🏗️\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eBuilding Automation\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eHVAC control systems\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eLighting control networks\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eAccess control panels\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eFire alarm systems\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eEnergy management devices\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eBuilding management systems (BMS)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e🚂\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eTransportation \u0026amp; Infrastructure\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eRailway signaling systems\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eTraffic management and ITS\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eAirport ground support equipment\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eParking management systems\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eFleet management devices\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eVehicle telematics\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e📡\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eTelecommunications\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eNetwork equipment management\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eBase station controllers\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eTelecom infrastructure monitoring\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eRemote site management\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSerial console servers\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e🔬\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eLaboratory \u0026amp; Research\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eAnalytical instrument networking\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eData acquisition systems\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eEnvironmental monitoring\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eQuality control equipment\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eTest and measurement devices\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e🏥\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eMedical \u0026amp; Healthcare\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eMedical equipment networking\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eLaboratory automation\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003ePatient monitoring systems\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eHospital infrastructure management\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eDiagnostic equipment integration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e🔧\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eSecurity \u0026amp; Access Control\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eCard readers and access panels\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eCCTV camera control (PTZ)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eIntrusion detection systems\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eFire alarm panels\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003ePerimeter security systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr class=\"my-7 border-neutral-300 dark:border-neutral-700\"\u003e\n\u003ch2 class=\"mb-2 mt-4 break-words text-xl font-semibold\"\u003eWhat's Included\u003c\/h2\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e✓\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eCSE-B63G RS-232\/RS-485 to Ethernet Module\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e(1 unit)\u003cbr\u003e✓\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eDocumentation:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eDatasheet (PDF)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eUser manual (available for download)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eIntegration guide\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e✓\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eSoftware available for download:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eezManager (Configuration utility for Windows)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eezVSP (Virtual Serial Port driver for Windows)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eezTerm (TCP\/IP communication test tool)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cem\u003eAll software is available for download from the Sollae Systems ezTCP website. See the link under the \u003cstrong\u003eTechnical Support \u0026amp; Resource\u003c\/strong\u003es section below.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eNote:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eThis is a board-type module. Power supply (5V DC) and appropriate connectors are required for installation.\u003c\/p\u003e\n\u003chr class=\"my-7 border-neutral-300 dark:border-neutral-700\"\u003e\n\u003ch2 class=\"mb-2 mt-4 break-words text-xl font-semibold\"\u003eQuick Setup Guide\u003c\/h2\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eStep 1: Hardware Installation\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003ePower Connection:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eConnect a regulated 5V DC power supply\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eObserve polarity (reverse voltage protection included)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eTypical current: 133-173mA depending on Ethernet speed\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eSerial Interface Connection:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eChoose one interface based on your application:\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eRS-232:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eConnect RXD, TXD, RTS, CTS, GND\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eRS-485:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eConnect TRX+, TRX-, GND (biasing resistors built-in)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eEthernet Connection:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eConnect standard Ethernet cable to RJ-45 port\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eAuto MDI\/MDIX supports both straight and crossover cables\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eAuto-sensing 10\/100 Mbps\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eStep 2: Initial Configuration\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eDefault Settings:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eCommunication Mode:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eTCP Server\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eSerial Interface:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eRS-232\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eBaud Rate:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e19,200 bps (typical default)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eData Format:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e8-N-1 (8 data bits, No parity, 1 stop bit)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eConfiguration Methods:\u003c\/span\u003e\u003c\/p\u003e\n\u003col class=\"ml-8 list-outside list-decimal\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eVia Ethernet:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eUse ezManager to discover and configure (recommended)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eVia Telnet:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eConnect via Telnet for remote configuration\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eAT Commands:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eUse AT command mode for dynamic configuration\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eStep 3: Testing\u003c\/span\u003e\u003c\/h3\u003e\n\u003col class=\"ml-8 list-outside list-decimal\"\u003e\n\u003cli class=\"py-0.5\"\u003ePower on the module\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eVerify LED indicators (PWR, LINK, STS)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eUse ezManager to discover module on network\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eConfigure network and serial parameters\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eTest data communication using ezTerm\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eVerify bidirectional data flow\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eTotal setup time: 15-30 minutes\u003c\/span\u003e\u003c\/p\u003e\n\u003chr class=\"my-7 border-neutral-300 dark:border-neutral-700\"\u003e\n\u003ch2 class=\"mb-2 mt-4 break-words text-xl font-semibold\"\u003eAdvanced Features \u0026amp; Capabilities\u003c\/h2\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eIPv6 Dual Stack Implementation\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eThe CSE-B63G is fully IPv6-ready with comprehensive support:\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eIPv6 Features:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eFull IPv4\/IPv6 dual stack operation\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eICMPv6, TCPv6, UDPv6 protocols\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSeamless IPv4\/IPv6 interoperability\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eFuture-proof network compatibility\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eWhy IPv6 Matters:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eLarger address space for IoT deployments\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eImproved security with IPsec integration\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eBetter support for mobile devices\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSimplified network configuration\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eEssential for modern industrial networks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eTLS v1.2 Security\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eSecure Socket Layer Protection:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eEncrypt serial data over the network\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eProtect sensitive information in transit\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eIndustry-standard TLS v1.2 protocol\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eCertificate-based authentication\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003ePrevents eavesdropping and tampering\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eSecurity Features:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eIP address filtering (whitelist\/blacklist)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eMAC address filtering\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003ePassword-protected configuration\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eRestrict access to authorized systems only\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003ePacket Fragmentation Control\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eSeparator Settings:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eDefine custom packet delimiters\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eControl when data is transmitted over network\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eOptimize for different protocols and applications\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eReduce network overhead\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eImprove application-level parsing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eBenefits:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eBetter protocol compatibility\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eReduced latency for time-critical data\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eImproved bandwidth efficiency\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eFlexible data handling\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eAT Command Mode (Patented)\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eDynamic Control:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eChange connection parameters at runtime\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eEstablish\/terminate connections via serial commands\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eNo device reboot required\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003ePerfect for applications requiring dynamic connectivity\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eUnique Sollae Systems technology\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eAT Command Capabilities:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eConfigure IP addresses and ports\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eEstablish TCP connections\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eControl DHCP and PPPoE\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSet DNS servers\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eModify timeout values\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSave settings to flash memory\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eRS-485 Built-In Features\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eIntegrated Biasing:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e3.9kΩ biasing resistors built-in\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSimplifies RS-485 network installation\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eImproves signal integrity\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eReduces external components\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eRS-485 Benefits:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eLong-distance communication (up to 4,000 feet)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eMulti-drop networks (up to 32 devices)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eExcellent noise immunity\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eDifferential signaling\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eIdeal for industrial environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr class=\"my-7 border-neutral-300 dark:border-neutral-700\"\u003e\n\u003ch2 class=\"mb-2 mt-4 break-words text-xl font-semibold\"\u003eSoftware Suite\u003c\/h2\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eezManager - Configuration Utility\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eComprehensive Management Tool for Windows:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eFeatures:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eAutomatic device discovery via network\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eIntuitive graphical interface\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eReal-time status monitoring\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eFirmware update management\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eConfiguration backup and restore\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSimple test utility included\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eBatch configuration for multiple devices\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eConfiguration Methods:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eVia Ethernet (LAN)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eVia Serial port\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eRemote configuration via Telnet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eezVSP - Virtual Serial Port Driver\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eWindows Virtual COM Port Driver:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eFeatures:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eCreates virtual COM ports on Windows PC\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eLegacy applications work without modification\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eAutomatic reconnection on network interruption\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eCompatible with Windows 7\/8\/10\/11\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eNo application changes required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eHow It Works:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eThe CSE-B63G appears as a local COM port on your Windows PC. Your existing serial software communicates with the virtual port, and ezVSP handles all network communication transparently.\u003c\/p\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eezTerm - Communication Test Tool\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eSimple TCP\/IP Testing:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eFeatures:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eQuick TCP\/IP communication testing\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eBoth TCP and UDP support\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eServer and client modes\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eHex and ASCII data display\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eData logging capabilities\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003ePerfect for troubleshooting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr class=\"my-7 border-neutral-300 dark:border-neutral-700\"\u003e\n\u003ch2 class=\"mb-2 mt-4 break-words text-xl font-semibold\"\u003eIndustrial Protection Features\u003c\/h2\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eReverse Voltage Protection\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eProtects against incorrect power polarity\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003ePrevents damage from installation errors\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eEssential for field installations\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eIncreases reliability and uptime\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eSurge Protection\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eGuards against voltage spikes and transients\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eProtects from electrical noise in industrial environments\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eExtends module lifespan\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eReduces field failures\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eIndustrial Temperature Range\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eOperates reliably from -40°C to +85°C\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSuitable for outdoor installations\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eHandles extreme environmental conditions\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eNo derating required within spec range\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr class=\"my-7 border-neutral-300 dark:border-neutral-700\"\u003e\n\u003ch2 class=\"mb-2 mt-4 break-words text-xl font-semibold\"\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cstrong\u003e\u003cspan class=\"font-semibold\"\u003eQ: What's the difference between CSE-B63G and CSE-H53N?\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003eA: The CSE-B63G is a board-type module (80x45x17mm) supporting both RS-232 and RS-485, while the CSE-H53N is a standalone converter with enclosure supporting RS-232 only. Choose CSE-B63G for OEM integration and dual-interface flexibility, CSE-H53N for standalone plug-and-play applications.\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cstrong\u003e\u003cspan class=\"font-semibold\"\u003eQ: Can I use both RS-232 and RS-485 simultaneously?\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003eA: No, the module has one UART that can be configured for either RS-232 or RS-485 operation. You select the interface based on your application needs.\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cstrong\u003e\u003cspan class=\"font-semibold\"\u003eQ: Does the module include RS-485 termination resistors?\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003eA: The CSE-B63G includes 3.9kΩ biasing resistors but does not include 120Ω termination resistors. Add external 120Ω termination resistors at both ends of your RS-485 bus as needed.\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cstrong\u003e\u003cspan class=\"font-semibold\"\u003eQ: What are the built-in 3.9kΩ biasing resistors for?\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003eA: The 3.9kΩ biasing resistors help maintain the RS-485 bus in a known state when no devices are transmitting, improving signal integrity and reducing noise sensitivity.\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cstrong\u003e\u003cspan class=\"font-semibold\"\u003eQ: Does the CSE-B63G support IPv6?\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003eA: Yes! Full IPv4\/IPv6 dual stack support with ICMPv6, TCPv6, and UDPv6 protocols. It's fully ready for modern IPv6 networks.\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cstrong\u003e\u003cspan class=\"font-semibold\"\u003eQ: What is the maximum baud rate?\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003eA: Up to 921.6 kbps under certain conditions. Standard operation supports up to 230.4 kbps reliably for both RS-232 and RS-485.\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cstrong\u003e\u003cspan class=\"font-semibold\"\u003eQ: How do I configure the module?\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003eA: Three methods: (1) ezManager via Ethernet (easiest), (2) Telnet for remote configuration, (3) AT commands via serial terminal for dynamic control. Choose the method that works best for your deployment.\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cstrong\u003e\u003cspan class=\"font-semibold\"\u003eQ: Can I use this in outdoor applications?\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003eA: Yes! The module is rated for industrial temperatures (-40°C to +85°C) and includes surge protection. However, it's not waterproof—install in a weatherproof enclosure for outdoor use.\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cstrong\u003e\u003cspan class=\"font-semibold\"\u003eQ: What security features are included?\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003eA: TLS v1.2 encryption, IP\/MAC address filtering, and password-protected configuration. This provides enterprise-grade security for industrial control applications.\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cstrong\u003e\u003cspan class=\"font-semibold\"\u003eQ: What is AT Command mode?\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003eA: AT Command mode is a patented \u003cem\u003eSollae Systems\u003c\/em\u003e feature that allows you to control TCP\/IP connections dynamically via serial AT commands. You can establish connections, change IP addresses, and configure network parameters without rebooting the device.\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cstrong\u003e\u003cspan class=\"font-semibold\"\u003eQ: Is the CSE-B63G module compatible with Modbus?\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003eA: Yes, the CSE-B63G can transport Modbus RTU (serial) over TCP\/IP networks, enabling Modbus TCP functionality. Configure the module in transparent mode for Modbus applications.\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cstrong\u003e\u003cspan class=\"font-semibold\"\u003eQ: What power supply do I need?\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003eA: Regulated 5V DC power supply capable of at least 200mA (173mA max consumption + safety margin). The module includes reverse voltage protection.\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e.\u003c\/p\u003e\n\u003chr class=\"my-7 border-neutral-300 dark:border-neutral-700\"\u003e\n\u003ch2\u003e\u003cspan class=\"italic\"\u003eTechnical Support \u0026amp; Resources\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.eztcp.com\/en\/products\/cse-b63g\" title=\"CSE-B63G \/ Embedded RS232\/RS485 to Ethernet board\" rel=\"noopener\" target=\"_blank\"\u003e\u003cstrong\u003eCSE-B63G RS-232\/RS-485 Serial to Ethernet Module Product Page\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.eztcp.com\/en\/download\/utility.php\" target=\"_blank\"\u003e\u003cstrong\u003eEZTCP Utility Downloads\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.eztcp.com\/en\/download\/pds_files\/ds_cseb63gen.pdf\" title=\"CSE-B63G embedded RS232\/RS485 to Ethernet board Datasheet\" rel=\"noopener\" target=\"_blank\"\u003e\u003cstrong\u003eCSE-B63G Embedded Serial to Ethernet Module Datasheet\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.eztcp.com\/en\/download\/pds_files\/csem53gen.pdf\" title=\"CSE-M53G Embedded Serial to Ethernet Module User Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003cstrong\u003eCSE-M53G Embedded Serial to Ethernet Module User Manual\u003c\/strong\u003e\u003c\/a\u003e (The CSE-M53G module is the core of the CSE-B63G.)\u003c\/p\u003e","brand":"Sollae Systems","offers":[{"title":"Default Title","offer_id":47500528091385,"sku":"CSE-B63G-BO","price":89.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1641\/0911\/files\/sollae-systems-cse-b63g-industrial-rs-232rs-485-serial-to-ethernet-module-3168587.jpg?v=1773275046"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1641\/0911\/collections\/Serial-to-Ethernet-Converters-Collection-Page-1.png?v=1784747298","url":"https:\/\/envistiamall.com\/collections\/serial-to-ethernet-device-servers.oembed","provider":"Envistia Mall","version":"1.0","type":"link"}