{"product_id":"cse-b63g-embedded-rs232-rs485-serial-to-ethernet-module","title":"Sollae Systems CSE-B63G Industrial RS-232\/RS-485 Serial to Ethernet Module","description":"\u003cp\u003eThe Sollae Systems CSE-B63G is a professional board-type RS-232 and RS-485 serial-to-Ethernet module built around the proven ezTCP CSE-M53G module core. Designed for OEM integration and industrial applications, the CSE-B63G features integrated DB9-M serial connector and RJ-45 Ethernet connector mounted directly on the board, eliminating the need for additional circuitry and dramatically simplifying integration. With support for both RS-232 and RS-485 interfaces, IPv4\/IPv6 dual stack networking, industrial temperature range (-40°C to +85°C), and advanced security features including TLS v1.2, the CSE-B63G delivers enterprise-level performance in a compact 80mm x 45mm board format perfect for embedded applications, control panels, and harsh industrial environments.\u003c\/p\u003e\n\u003chr class=\"my-7 border-neutral-300 dark:border-neutral-700\"\u003e\n\u003ch2 class=\"mb-2 mt-4 break-words text-xl font-semibold\"\u003eWhy Choose the CSE-B63G?\u003c\/h2\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e🔄\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eDual Serial Interface Support\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eSingle module supports both RS-232 and RS-485 interfaces. Switch between interfaces based on your application needs without changing hardware—maximum flexibility for diverse deployment scenarios.\u003c\/p\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e🏭\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eIndustrial-Grade Reliability\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eExtreme temperature range (-40°C to +85°C) and robust design with reverse voltage and surge protection make this module perfect for harsh industrial environments where consumer-grade equipment fails.\u003c\/p\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e📦\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eCompact Board Design\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eAt just 80mm x 45mm x 17mm, the CSE-B63G provides a complete serial-to-Ethernet solution in a board format perfect for embedding directly into equipment, control panels, and industrial enclosures.\u003c\/p\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e🌐\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eFuture-Proof IPv6 Support\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eFull IPv4\/IPv6 dual stack implementation ensures compatibility with modern networks and future IPv6 deployments. Ready for today's infrastructure and tomorrow's requirements.\u003c\/p\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e🔒\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eEnhanced Security\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eBuilt-in TLS v1.2 encryption, IP\/MAC filtering, and password protection ensure your serial data remains secure across the network. Enterprise-grade security for industrial control applications.\u003c\/p\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e⚡\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eHigh-Speed Performance\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eUART support up to 921.6 kbps (under certain conditions) ensures fast, reliable data transfer for even the most demanding serial applications.\u003c\/p\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e🔌\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eBuilt-In RS-485 Features\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eIntegrated 3.9kΩ biasing resistors for RS-485 simplify installation and improve reliability. No external biasing components required.\u003c\/p\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e🎯\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eFlexible Configuration\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eConfigure via Ethernet (ezManager), Telnet, or AT commands. Choose the method that works best for your deployment scenario. Patented AT command mode allows dynamic runtime configuration.\u003c\/p\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e🛡️\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eProtection Circuitry\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eBuilt-in reverse voltage and surge protection safeguard the module from electrical transients and installation errors common in industrial environments.\u003c\/p\u003e\n\u003chr class=\"my-7 border-neutral-300 dark:border-neutral-700\"\u003e\n\u003ch2 class=\"mb-2 mt-4 break-words text-xl font-semibold\"\u003eCSE-B63G Technical Specifications\u003c\/h2\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003eSerial Interface\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003ePhysical Interfaces:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eRS-232:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eRXD, TXD, CTS, RTS, GND\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eRS-485:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eTRX+, TRX-, GND (with built-in 3.9kΩ biasing resistors)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eSerial Parameters:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eBaud Rate:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e300 to 921,600 bps (up to 921.6 kbps under certain conditions)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eData Bits:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e8 bits, 7 bits (with parity)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eParity:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eNone, Even, Odd, Mark, Space\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eStop Bits:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e1, 2\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eFlow Control:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eRTS\/CTS (RS-232)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eNote:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eA single idle bit is automatically added after every stop bit by the MCU function.\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eRS-485 Features:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eBuilt-in 3.9kΩ biasing resistors\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eHalf-duplex communication\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eMulti-drop network support\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eDifferential signaling for noise immunity\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003eNetwork Interface\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eEthernet:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003ePort:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eRJ-45 connector\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eSpeed:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e10Base-T or 100Base-TX (Auto-Sensing)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eCable Detection:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eAuto MDI\/MDIX (works with straight or crossover cables)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eNetwork Protocols:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eIPv4\/IPv6:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eDual stack support\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eIPv6 Protocols:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eICMPv6, TCPv6, UDPv6\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eIPv4 Protocols:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eTCP, UDP, IP, ICMP, ARP, Telnet\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eNetwork Services:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eDHCP, PPPoE, DNS, DDNS\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eSecurity:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eSSL\/TLS v1.2 (Secure Socket Layer)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003eCommunication Modes\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eTCP Server (T2S):\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003ePassive connection mode\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eWaits for incoming TCP client connections\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eIdeal for centralized monitoring applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eTCP Client (COD):\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eActive connection mode\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eInitiates connection to remote TCP server\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003ePerfect for data logging and cloud integration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eAT Command Mode (ATC) - Patented:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eControl connections dynamically via AT commands\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eBoth active and passive connections supported\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eAllows runtime configuration changes\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eUnique Sollae Systems technology\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eUDP Mode (U2S):\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eConnectionless communication\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eBroadcast and multicast support\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eLow-latency data transfer\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003eSecurity Features\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eTLS v1.2:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eSecure Socket Layer encryption\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eProtect sensitive data in transit\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eIndustry-standard security protocol\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eAccess Control:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eIP address filtering (whitelist\/blacklist)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eMAC address filtering\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eRestrict access to specific hosts or networks\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003ePassword-protected configuration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003eAdvanced Features\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003ePacket Fragmentation Control:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eSeparator settings for packet fragmentation\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eDefine custom packet delimiters\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eOptimize for different protocols and applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eAdditional Functions:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eTCP Server\/Client mode switching\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSending MAC address option\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eFlexible data handling\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003ePower Specifications\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eInput Voltage:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eDC 5V\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eCurrent Consumption:\u003c\/span\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e100M Ethernet: 133mA\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e10M Ethernet: 173mA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eProtection:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eReverse voltage and surge protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003eEnvironmental Specifications\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eOperating Temperature:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e-40°C to +85°C (-40°F to 185°F)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eStorage Temperature:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e-40°C to +85°C\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eHumidity:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e5% to 95% RH, non-condensing (typical for industrial modules)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003ePhysical Specifications\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eDimensions:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e80mm (W) x 45mm (L) x 17mm (H) (3.15\" x 1.77\" x 0.67\")\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eForm Factor:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eBoard-type module\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eMounting:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003ePCB mounting or panel mounting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003eStatus Indicators (LEDs)\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eSystem LEDs:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003ePWR:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003ePower indicator\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eLINK:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eEthernet link status\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eSTS:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eSystem status\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eTCP:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eTCP connection status\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eNetwork LEDs:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eTXD:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eNetwork transmit activity\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eRXD:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eNetwork receive activity\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eSerial LEDs:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eTXD:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eSerial transmit activity\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eRXD:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eSerial receive activity\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eRTS:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eRequest To Send status\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eCTS:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eClear To Send status\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr class=\"my-7 border-neutral-300 dark:border-neutral-700\"\u003e\n\u003ch2 class=\"mb-2 mt-4 break-words text-xl font-semibold\"\u003eReal-World Applications\u003c\/h2\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e🏭\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eIndustrial Automation \u0026amp; Control\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003ePLC networking and remote monitoring\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSCADA system integration\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eFactory automation equipment\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eProcess control devices\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eManufacturing machinery networking\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eIndustrial sensor networks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e⚡\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eEnergy \u0026amp; Utilities\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eSmart grid monitoring and control\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSubstation automation\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003ePower distribution management\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eRemote meter reading (AMR\/AMI)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSolar inverter monitoring\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eBattery management systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e🏗️\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eBuilding Automation\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eHVAC control systems\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eLighting control networks\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eAccess control panels\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eFire alarm systems\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eEnergy management devices\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eBuilding management systems (BMS)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e🚂\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eTransportation \u0026amp; Infrastructure\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eRailway signaling systems\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eTraffic management and ITS\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eAirport ground support equipment\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eParking management systems\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eFleet management devices\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eVehicle telematics\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e📡\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eTelecommunications\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eNetwork equipment management\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eBase station controllers\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eTelecom infrastructure monitoring\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eRemote site management\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSerial console servers\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e🔬\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eLaboratory \u0026amp; Research\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eAnalytical instrument networking\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eData acquisition systems\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eEnvironmental monitoring\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eQuality control equipment\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eTest and measurement devices\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e🏥\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eMedical \u0026amp; Healthcare\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eMedical equipment networking\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eLaboratory automation\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003ePatient monitoring systems\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eHospital infrastructure management\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eDiagnostic equipment integration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e🔧\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eSecurity \u0026amp; Access Control\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eCard readers and access panels\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eCCTV camera control (PTZ)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eIntrusion detection systems\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eFire alarm panels\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003ePerimeter security systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr class=\"my-7 border-neutral-300 dark:border-neutral-700\"\u003e\n\u003ch2 class=\"mb-2 mt-4 break-words text-xl font-semibold\"\u003eWhat's Included\u003c\/h2\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e✓\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eCSE-B63G RS-232\/RS-485 to Ethernet Module\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e(1 unit)\u003cbr\u003e✓\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eDocumentation:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eDatasheet (PDF)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eUser manual (available for download)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eIntegration guide\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e✓\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eSoftware available for download:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eezManager (Configuration utility for Windows)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eezVSP (Virtual Serial Port driver for Windows)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eezTerm (TCP\/IP communication test tool)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cem\u003eAll software is available for download from the Sollae Systems ezTCP website. See the link under the \u003cstrong\u003eTechnical Support \u0026amp; Resource\u003c\/strong\u003es section below.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eNote:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eThis is a board-type module. Power supply (5V DC) and appropriate connectors are required for installation.\u003c\/p\u003e\n\u003chr class=\"my-7 border-neutral-300 dark:border-neutral-700\"\u003e\n\u003ch2 class=\"mb-2 mt-4 break-words text-xl font-semibold\"\u003eQuick Setup Guide\u003c\/h2\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eStep 1: Hardware Installation\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003ePower Connection:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eConnect a regulated 5V DC power supply\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eObserve polarity (reverse voltage protection included)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eTypical current: 133-173mA depending on Ethernet speed\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eSerial Interface Connection:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eChoose one interface based on your application:\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eRS-232:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eConnect RXD, TXD, RTS, CTS, GND\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eRS-485:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eConnect TRX+, TRX-, GND (biasing resistors built-in)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eEthernet Connection:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eConnect standard Ethernet cable to RJ-45 port\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eAuto MDI\/MDIX supports both straight and crossover cables\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eAuto-sensing 10\/100 Mbps\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eStep 2: Initial Configuration\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eDefault Settings:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eCommunication Mode:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eTCP Server\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eSerial Interface:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eRS-232\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eBaud Rate:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e19,200 bps (typical default)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eData Format:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e8-N-1 (8 data bits, No parity, 1 stop bit)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eConfiguration Methods:\u003c\/span\u003e\u003c\/p\u003e\n\u003col class=\"ml-8 list-outside list-decimal\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eVia Ethernet:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eUse ezManager to discover and configure (recommended)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eVia Telnet:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eConnect via Telnet for remote configuration\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eAT Commands:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eUse AT command mode for dynamic configuration\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eStep 3: Testing\u003c\/span\u003e\u003c\/h3\u003e\n\u003col class=\"ml-8 list-outside list-decimal\"\u003e\n\u003cli class=\"py-0.5\"\u003ePower on the module\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eVerify LED indicators (PWR, LINK, STS)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eUse ezManager to discover module on network\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eConfigure network and serial parameters\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eTest data communication using ezTerm\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eVerify bidirectional data flow\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eTotal setup time: 15-30 minutes\u003c\/span\u003e\u003c\/p\u003e\n\u003chr class=\"my-7 border-neutral-300 dark:border-neutral-700\"\u003e\n\u003ch2 class=\"mb-2 mt-4 break-words text-xl font-semibold\"\u003eAdvanced Features \u0026amp; Capabilities\u003c\/h2\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eIPv6 Dual Stack Implementation\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eThe CSE-B63G is fully IPv6-ready with comprehensive support:\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eIPv6 Features:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eFull IPv4\/IPv6 dual stack operation\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eICMPv6, TCPv6, UDPv6 protocols\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSeamless IPv4\/IPv6 interoperability\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eFuture-proof network compatibility\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eWhy IPv6 Matters:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eLarger address space for IoT deployments\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eImproved security with IPsec integration\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eBetter support for mobile devices\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSimplified network configuration\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eEssential for modern industrial networks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eTLS v1.2 Security\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eSecure Socket Layer Protection:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eEncrypt serial data over the network\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eProtect sensitive information in transit\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eIndustry-standard TLS v1.2 protocol\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eCertificate-based authentication\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003ePrevents eavesdropping and tampering\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eSecurity Features:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eIP address filtering (whitelist\/blacklist)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eMAC address filtering\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003ePassword-protected configuration\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eRestrict access to authorized systems only\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003ePacket Fragmentation Control\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eSeparator Settings:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eDefine custom packet delimiters\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eControl when data is transmitted over network\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eOptimize for different protocols and applications\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eReduce network overhead\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eImprove application-level parsing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eBenefits:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eBetter protocol compatibility\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eReduced latency for time-critical data\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eImproved bandwidth efficiency\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eFlexible data handling\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eAT Command Mode (Patented)\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eDynamic Control:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eChange connection parameters at runtime\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eEstablish\/terminate connections via serial commands\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eNo device reboot required\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003ePerfect for applications requiring dynamic connectivity\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eUnique Sollae Systems technology\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eAT Command Capabilities:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eConfigure IP addresses and ports\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eEstablish TCP connections\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eControl DHCP and PPPoE\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSet DNS servers\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eModify timeout values\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSave settings to flash memory\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eRS-485 Built-In Features\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eIntegrated Biasing:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e3.9kΩ biasing resistors built-in\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSimplifies RS-485 network installation\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eImproves signal integrity\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eReduces external components\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eRS-485 Benefits:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eLong-distance communication (up to 4,000 feet)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eMulti-drop networks (up to 32 devices)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eExcellent noise immunity\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eDifferential signaling\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eIdeal for industrial environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr class=\"my-7 border-neutral-300 dark:border-neutral-700\"\u003e\n\u003ch2 class=\"mb-2 mt-4 break-words text-xl font-semibold\"\u003eSoftware Suite\u003c\/h2\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eezManager - Configuration Utility\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eComprehensive Management Tool for Windows:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eFeatures:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eAutomatic device discovery via network\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eIntuitive graphical interface\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eReal-time status monitoring\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eFirmware update management\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eConfiguration backup and restore\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSimple test utility included\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eBatch configuration for multiple devices\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eConfiguration Methods:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eVia Ethernet (LAN)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eVia Serial port\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eRemote configuration via Telnet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eezVSP - Virtual Serial Port Driver\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eWindows Virtual COM Port Driver:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eFeatures:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eCreates virtual COM ports on Windows PC\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eLegacy applications work without modification\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eAutomatic reconnection on network interruption\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eCompatible with Windows 7\/8\/10\/11\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eNo application changes required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eHow It Works:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eThe CSE-B63G appears as a local COM port on your Windows PC. Your existing serial software communicates with the virtual port, and ezVSP handles all network communication transparently.\u003c\/p\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eezTerm - Communication Test Tool\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eSimple TCP\/IP Testing:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eFeatures:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eQuick TCP\/IP communication testing\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eBoth TCP and UDP support\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eServer and client modes\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eHex and ASCII data display\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eData logging capabilities\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003ePerfect for troubleshooting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr class=\"my-7 border-neutral-300 dark:border-neutral-700\"\u003e\n\u003ch2 class=\"mb-2 mt-4 break-words text-xl font-semibold\"\u003eIndustrial Protection Features\u003c\/h2\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eReverse Voltage Protection\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eProtects against incorrect power polarity\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003ePrevents damage from installation errors\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eEssential for field installations\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eIncreases reliability and uptime\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eSurge Protection\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eGuards against voltage spikes and transients\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eProtects from electrical noise in industrial environments\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eExtends module lifespan\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eReduces field failures\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eIndustrial Temperature Range\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eOperates reliably from -40°C to +85°C\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSuitable for outdoor installations\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eHandles extreme environmental conditions\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eNo derating required within spec range\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr class=\"my-7 border-neutral-300 dark:border-neutral-700\"\u003e\n\u003ch2 class=\"mb-2 mt-4 break-words text-xl font-semibold\"\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cstrong\u003e\u003cspan class=\"font-semibold\"\u003eQ: What's the difference between CSE-B63G and CSE-H53N?\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003eA: The CSE-B63G is a board-type module (80x45x17mm) supporting both RS-232 and RS-485, while the CSE-H53N is a standalone converter with enclosure supporting RS-232 only. Choose CSE-B63G for OEM integration and dual-interface flexibility, CSE-H53N for standalone plug-and-play applications.\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cstrong\u003e\u003cspan class=\"font-semibold\"\u003eQ: Can I use both RS-232 and RS-485 simultaneously?\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003eA: No, the module has one UART that can be configured for either RS-232 or RS-485 operation. You select the interface based on your application needs.\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cstrong\u003e\u003cspan class=\"font-semibold\"\u003eQ: Does the module include RS-485 termination resistors?\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003eA: The CSE-B63G includes 3.9kΩ biasing resistors but does not include 120Ω termination resistors. Add external 120Ω termination resistors at both ends of your RS-485 bus as needed.\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cstrong\u003e\u003cspan class=\"font-semibold\"\u003eQ: What are the built-in 3.9kΩ biasing resistors for?\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003eA: The 3.9kΩ biasing resistors help maintain the RS-485 bus in a known state when no devices are transmitting, improving signal integrity and reducing noise sensitivity.\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cstrong\u003e\u003cspan class=\"font-semibold\"\u003eQ: Does the CSE-B63G support IPv6?\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003eA: Yes! Full IPv4\/IPv6 dual stack support with ICMPv6, TCPv6, and UDPv6 protocols. It's fully ready for modern IPv6 networks.\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cstrong\u003e\u003cspan class=\"font-semibold\"\u003eQ: What is the maximum baud rate?\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003eA: Up to 921.6 kbps under certain conditions. Standard operation supports up to 230.4 kbps reliably for both RS-232 and RS-485.\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cstrong\u003e\u003cspan class=\"font-semibold\"\u003eQ: How do I configure the module?\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003eA: Three methods: (1) ezManager via Ethernet (easiest), (2) Telnet for remote configuration, (3) AT commands via serial terminal for dynamic control. Choose the method that works best for your deployment.\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cstrong\u003e\u003cspan class=\"font-semibold\"\u003eQ: Can I use this in outdoor applications?\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003eA: Yes! The module is rated for industrial temperatures (-40°C to +85°C) and includes surge protection. However, it's not waterproof—install in a weatherproof enclosure for outdoor use.\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cstrong\u003e\u003cspan class=\"font-semibold\"\u003eQ: What security features are included?\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003eA: TLS v1.2 encryption, IP\/MAC address filtering, and password-protected configuration. This provides enterprise-grade security for industrial control applications.\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cstrong\u003e\u003cspan class=\"font-semibold\"\u003eQ: What is AT Command mode?\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003eA: AT Command mode is a patented \u003cem\u003eSollae Systems\u003c\/em\u003e feature that allows you to control TCP\/IP connections dynamically via serial AT commands. You can establish connections, change IP addresses, and configure network parameters without rebooting the device.\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cstrong\u003e\u003cspan class=\"font-semibold\"\u003eQ: Is the CSE-B63G module compatible with Modbus?\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003eA: Yes, the CSE-B63G can transport Modbus RTU (serial) over TCP\/IP networks, enabling Modbus TCP functionality. Configure the module in transparent mode for Modbus applications.\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cstrong\u003e\u003cspan class=\"font-semibold\"\u003eQ: What power supply do I need?\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003eA: Regulated 5V DC power supply capable of at least 200mA (173mA max consumption + safety margin). The module includes reverse voltage protection.\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e.\u003c\/p\u003e\n\u003chr class=\"my-7 border-neutral-300 dark:border-neutral-700\"\u003e\n\u003ch2\u003e\u003cspan class=\"italic\"\u003eTechnical Support \u0026amp; Resources\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.eztcp.com\/en\/products\/cse-b63g\" title=\"CSE-B63G \/ Embedded RS232\/RS485 to Ethernet board\" rel=\"noopener\" target=\"_blank\"\u003e\u003cstrong\u003eCSE-B63G RS-232\/RS-485 Serial to Ethernet Module Product Page\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.eztcp.com\/en\/download\/utility.php\" target=\"_blank\"\u003e\u003cstrong\u003eEZTCP Utility Downloads\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.eztcp.com\/en\/download\/pds_files\/ds_cseb63gen.pdf\" title=\"CSE-B63G embedded RS232\/RS485 to Ethernet board Datasheet\" rel=\"noopener\" target=\"_blank\"\u003e\u003cstrong\u003eCSE-B63G Embedded Serial to Ethernet Module Datasheet\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.eztcp.com\/en\/download\/pds_files\/csem53gen.pdf\" title=\"CSE-M53G Embedded Serial to Ethernet Module User Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003cstrong\u003eCSE-M53G Embedded Serial to Ethernet Module User Manual\u003c\/strong\u003e\u003c\/a\u003e (The CSE-M53G module is the core of the CSE-B63G.)\u003c\/p\u003e","brand":"Sollae Systems","offers":[{"title":"Default Title","offer_id":47500528091385,"sku":"CSE-B63G-BO","price":89.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1641\/0911\/files\/sollae-systems-cse-b63g-industrial-rs-232rs-485-serial-to-ethernet-module-3168587.jpg?v=1773275046","url":"https:\/\/envistiamall.com\/es\/products\/cse-b63g-embedded-rs232-rs485-serial-to-ethernet-module","provider":"Envistia Mall","version":"1.0","type":"link"}