{"product_id":"sig-5530-4-port-analog-input-io-gateway-with-modbus-tcp","title":"Sollae Systems SIG-5530 4-Port Analog Input Ethernet I\/O Gateway with Modbus\/TCP","description":"\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eTransform your analog sensors into network-connected smart devices with the\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"font-semibold\"\u003eSollae Systems SIG-5530\u003c\/span\u003e—a professional-grade I\/O gateway that brings industrial monitoring into the modern era.\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eWhether you're monitoring temperature, pressure, flow, or any other analog measurement, the SIG-5530 makes it simple to integrate legacy sensors into your SCADA system, HMI, or monitoring platform using the industry-standard Modbus\/TCP protocol.\u003c\/p\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eWhat Makes the SIG-5530 Essential for Industrial Monitoring?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eThe SIG-5530 eliminates the complexity of analog sensor integration. Instead of running individual wires back to your control room, simply connect your sensors to the gateway, plug in an Ethernet cable, and access real-time data from anywhere on your network. It's that straightforward.\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eKey capabilities:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003e4 independent analog input ports\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003ethat you can configure individually for voltage (0-5V) or current (4-20mA \/ 0-20mA) measurements\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003e16-bit ADC resolution\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003edelivering 65,536 discrete values for precise monitoring\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eModbus\/TCP protocol\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003efor seamless integration with virtually any industrial control system\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eIndustrial temperature range\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003efrom -40°C to +85°C for reliable operation in harsh environments\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eMultiple simultaneous connections\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003esupporting up to 4 TCP sessions at once\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr class=\"my-7 border-neutral-300 dark:border-neutral-700\"\u003e\n\u003ch2 class=\"mb-2 mt-4 break-words text-xl font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eSIG-5530 TECHNICAL SPECIFICATIONS\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eAnalog Input Capabilities\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eNumber of Ports:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e4 independent channels\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eInput Types:\u003c\/span\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eVoltage: 0-5V DC\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eCurrent: 4-20mA (industry standard)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eCurrent: 0-20mA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eResolution:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e16-bit (0-65,535 values)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eTerminal Block:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e3.5mm pitch, 8-pole screw terminals\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003e1-bit ADC Function:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eConvert analog values to digital on\/off states for threshold-based control\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eNetwork Interface\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eEthernet:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e10\/100 Mbps auto-sensing (RJ45)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eCable Support:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eStraight-through or crossover cables (auto-detect)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eProtocols:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eModbus\/TCP, TCP\/UDP, ICMP, DHCP, mDNS, SSL\/TLS\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eIP Support:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eIPv4\/IPv6 dual stack\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eConnections:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eUp to 4 simultaneous TCP sessions\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eDefault Port:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e502 (Modbus\/TCP standard)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003ePower Requirements\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eInput Voltage:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eDC 5V ±0.5V\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eCurrent Draw:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eTypically 264mA\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eProtection:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eReverse voltage and surge protection built-in\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003ePhysical Specifications\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eDimensions:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e94mm × 57mm × 24mm (3.7\" × 2.2\" × 0.9\")\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eWeight:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eApproximately 65g (2.3 oz)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eMounting:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eCompact design for DIN rail or panel mounting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eEnvironmental\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eOperating Temperature:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e-40°C to +85°C (-40°F to +185°F)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eStorage Temperature:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e-40°C to +85°C (-40°F to +185°F)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eIndicators\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eLEDs:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eRUN (system status), LINK (network connection), MTX (transmit), MRX (receive)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eCertifications \u0026amp; Compliance\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eCE:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eEMC 2014\/30\/EU, RoHS 2011\/65\/EU\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eFCC:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003ePart 15 Subpart B, Class A\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eKC:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eRegistration (KN 32, KN 35)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr class=\"my-7 border-neutral-300 dark:border-neutral-700\"\u003e\n\u003ch2 class=\"mb-2 mt-4 break-words text-xl font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eWHAT'S INCLUDED\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eSIG-5530 4-Port Analog Input I\/O Gateway\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eQuick Start Guide\u003c\/li\u003e\n\u003cli\u003eFree spFinder configuration software (download from manufacturer)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem class=\"italic\"\u003eAll software is available for download from the Sollae Systems ezTCP website. See the link under the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTechnical Support \u0026amp; Resources\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esection below.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eNote:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003ePower supply (5V DC), Ethernet cable, and sensors sold separately.\u003c\/p\u003e\n\u003chr class=\"my-7 border-neutral-300 dark:border-neutral-700\"\u003e\n\u003ch2 class=\"mb-2 mt-4 break-words text-xl font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eKEY FEATURES \u0026amp; BENEFITS\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eFlexible Input Configuration\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eEach of the four analog input ports can be independently configured for your specific sensor type. Mix and match voltage and current sensors on the same gateway—perfect for diverse monitoring applications.\u003c\/p\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eTrue Industrial-Grade Reliability\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eWith an operating temperature range from -40°C to +85°C, the SIG-5530 handles extreme environments that would disable consumer-grade equipment. Built-in reverse voltage and surge protection safeguard your investment.\u003c\/p\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eModbus\/TCP Native Support\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eNo protocol conversion needed. The SIG-5530 speaks Modbus\/TCP natively, making integration with PLCs, SCADA systems, and HMIs completely straightforward. Access your sensor data using standard Modbus function codes.\u003c\/p\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eMultiple Simultaneous Connections\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eSupport up to 4 concurrent TCP sessions, allowing your HMI, SCADA system, data logger, and monitoring software to all access the gateway simultaneously without conflicts.\u003c\/p\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eSmart 1-bit ADC Function\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eConvert analog measurements into digital on\/off states based on configurable thresholds. Perfect for alarm conditions, threshold monitoring, or implementing \"Internet Switch\" functionality to trigger actions on other networked devices.\u003c\/p\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eEasy Configuration \u0026amp; Monitoring\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eThe included spFinder software provides an intuitive interface for:\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eDevice discovery on your network\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eComplete configuration management\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eReal-time monitoring of all analog inputs\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eViewing current, minimum, and maximum values\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eFirmware updates (online or manual)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eExport\/import of configuration settings\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eComprehensive Data Access\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eAccess sensor data in multiple formats via Modbus registers:\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eCurrent analog values (16-bit integer or 32-bit floating point)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eMinimum values recorded since last reset\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eMaximum values recorded since last reset\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e1-bit ADC states for threshold monitoring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr class=\"my-7 border-neutral-300 dark:border-neutral-700\"\u003e\n\u003ch2 class=\"mb-2 mt-4 break-words text-xl font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eTYPICAL APPLICATIONS\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eIndustrial Automation\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eMonitor process variables like temperature, pressure, flow rate, and level in manufacturing environments. Integrate seamlessly with existing PLCs and SCADA systems.\u003c\/p\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eEnvironmental Monitoring\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eTrack temperature, humidity, air quality, and other environmental parameters in facilities, greenhouses, or outdoor installations.\u003c\/p\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eEnergy Management\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eMonitor power consumption, voltage levels, and current draw across electrical systems for energy optimization and predictive maintenance.\u003c\/p\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eHVAC Systems\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eIntegrate temperature, pressure, and airflow sensors into building automation systems for efficient climate control.\u003c\/p\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eWater \u0026amp; Wastewater\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eMonitor flow rates, pressure, pH levels, and other critical parameters in water treatment and distribution systems.\u003c\/p\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eData Center Monitoring\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eTrack temperature, humidity, and power parameters across server rooms and equipment racks.\u003c\/p\u003e\n\u003chr class=\"my-7 border-neutral-300 dark:border-neutral-700\"\u003e\n\u003ch2 class=\"mb-2 mt-4 break-words text-xl font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eSETUP \u0026amp; CONFIGURATION\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eGetting Started in 5 Simple Steps:\u003c\/span\u003e\u003c\/h3\u003e\n\u003col class=\"ml-8 list-outside list-decimal\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003ePower Connection\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eConnect a 5V DC power supply to the 2-pole power terminal\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eObserve the RUN LED to confirm power-up\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eSensor Wiring\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eConnect your analog sensors to the 8-pole terminal block\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eConfigure each port for voltage (0-5V) or current (4-20mA \/ 0-20mA) input\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eNetwork Connection\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eConnect an Ethernet cable from your network to the RJ45 port\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eThe gateway supports both DHCP (automatic IP) and static IP addressing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eConfiguration\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eDownload and install the free spFinder software\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eSearch for the device on your network\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eLog in (default ID: sig-5530, password: sig-5530)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eConfigure network settings, TCP parameters, and analog input modes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eIntegration\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eAccess sensor data via Modbus\/TCP from your SCADA system or monitoring software\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eUse standard Modbus function codes to read registers\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eDefault Settings:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eLogin ID:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003esig-5530\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003ePassword:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003esig-5530 (change immediately for security)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eNetwork:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eDHCP enabled by default\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eTCP Port:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e502 (Modbus\/TCP standard)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eConnection Mode:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eTCP Server\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eAnalog Input Mode:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e0-5V (all ports)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr class=\"my-7 border-neutral-300 dark:border-neutral-700\"\u003e\n\u003ch2 class=\"mb-2 mt-4 break-words text-xl font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eMODBUS REGISTER MAP\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eThe SIG-5530 provides comprehensive data access through Modbus\/TCP registers:\u003c\/p\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eRead-Only Registers:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eAnalog Input Values\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e(16-bit integer format)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eMinimum Values\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e(since last reset)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eMaximum Values\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e(since last reset)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eAnalog Input Values\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e(32-bit floating point format)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003e1-bit ADC States\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e(digital on\/off values)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eDevice Information\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e(model, firmware version, uptime, etc.)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eRead\/Write Registers:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eReset Min\/Max Values\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e(clear recorded minimums and maximums)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eNotification Enable\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e(configure event notifications)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eComplete register addresses and function codes are detailed in the included user manual.\u003c\/p\u003e\n\u003chr class=\"my-7 border-neutral-300 dark:border-neutral-700\"\u003e\n\u003ch2 class=\"mb-2 mt-4 break-words text-xl font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eADVANCED FEATURES\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eInternet Switch Functionality\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eThe 1-bit ADC function enables sophisticated automation scenarios. Set high and low reference thresholds for each analog input, and the gateway converts continuous measurements into digital states. Use these states to trigger actions on other networked devices without requiring a central HMI.\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cspan class=\"font-semibold\"\u003eExample:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eWhen a temperature sensor exceeds a threshold, the gateway can signal a relay module to activate cooling equipment—all without human intervention.\u003c\/p\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eSecurity Features\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003ePassword Protection:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eSecure access to configuration settings\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eSSL\/TLS Support:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eEncrypted communications for sensitive data\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eIP Filtering:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eRestrict access to authorized hosts only\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eRemote Access Control:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eEnable\/disable remote configuration as needed\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eDiagnostic Capabilities\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eReal-time Statistics:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eMonitor TCP connection states, Modbus frame counts, and data throughput\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eCommunication Logging:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eTrack all Modbus queries, responses, and errors\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003e\n\u003cspan class=\"font-semibold\"\u003eLED Indicators:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eVisual feedback for power, network link, and data transmission\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr class=\"my-7 border-neutral-300 dark:border-neutral-700\"\u003e\n\u003ch2 class=\"mb-2 mt-4 break-words text-xl font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eCOMPATIBLE SENSORS\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003eThe SIG-5530 works with any analog sensor that outputs:\u003c\/p\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eVoltage Sensors (0-5V)\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eTemperature sensors (thermocouples with signal conditioning)\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003ePotentiometric sensors\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eAnalog output modules\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eVariable resistor sensors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mb-1 mt-4 break-words text-lg font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eCurrent Loop Sensors (4-20mA \/ 0-20mA)\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul class=\"ml-4 list-outside list-disc\"\u003e\n\u003cli class=\"py-0.5\"\u003eIndustrial pressure transmitters\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eFlow meters\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eLevel sensors\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003epH sensors\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eHumidity transmitters\u003c\/li\u003e\n\u003cli class=\"py-0.5\"\u003eAny 2-wire or 3-wire current loop sensor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr class=\"my-7 border-neutral-300 dark:border-neutral-700\"\u003e\n\u003ch2 class=\"mb-2 mt-4 break-words text-xl font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eFREQUENTLY ASKED QUESTIONS\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cstrong\u003e\u003cspan class=\"font-semibold\"\u003eQ: Can I mix voltage and current sensors on the same gateway?\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003eA: Yes! Each of the 4 ports can be independently configured for voltage (0-5V) or current (4-20mA \/ 0-20mA) input. Configure them individually based on your sensor requirements.\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cstrong\u003e\u003cspan class=\"font-semibold\"\u003eQ: What software do I need to read the sensor data?\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003eA: Any Modbus\/TCP client software will work. Popular options include ModScan, QModMaster, or integration directly into your SCADA system (Ignition, Wonderware, etc.). The free spFinder software is used for configuration and monitoring.\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cstrong\u003e\u003cspan class=\"font-semibold\"\u003eQ: How do I access the gateway remotely over the internet?\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003eA: Configure port forwarding on your router to forward external traffic to the gateway's IP address and port 502. For enhanced security, use a VPN connection instead of direct internet exposure. Remote access can be enabled\/disabled in the security settings.\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cstrong\u003e\u003cspan class=\"font-semibold\"\u003eQ: What's the difference between 4-20mA and 0-20mA current inputs?\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003eA: 4-20mA is the industrial standard where 4mA represents 0% of the measurement range and 20mA represents 100%. This \"live zero\" allows detection of broken wires (0mA). 0-20mA uses the full range from 0-100% but cannot detect wire breaks.\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cstrong\u003e\u003cspan class=\"font-semibold\"\u003eQ: Can multiple devices access the gateway simultaneously?\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003eA: Yes, the SIG-5530 supports up to 4 simultaneous TCP connections, allowing your HMI, SCADA system, data logger, and monitoring software to all connect at the same time.\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cstrong\u003e\u003cspan class=\"font-semibold\"\u003eQ: What power supply do I need?\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003eA: You need a regulated 5V DC power supply capable of at least 300mA (the gateway typically draws 264mA). Ensure the power supply is within the ±0.5V tolerance (4.5V to 5.5V).\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cstrong\u003e\u003cspan class=\"font-semibold\"\u003eQ: How accurate are the analog measurements?\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003eA: The SIG-5530 uses a 16-bit ADC providing 65,536 discrete values across the input range. For a 0-5V input, this gives approximately 76μV resolution. Actual accuracy depends on your sensor specifications and environmental factors.\u003c\/p\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cstrong\u003e\u003cspan class=\"font-semibold\"\u003eQ: Can I use this outdoors?\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003eA: The SIG-5530 operates reliably from -40°C to +85°C, but it should be installed in a weatherproof enclosure if used outdoors to protect against moisture and physical damage.\u003c\/p\u003e\n\u003chr class=\"my-7 border-neutral-300 dark:border-neutral-700\"\u003e\n\u003ch2 class=\"mb-2 mt-4 break-words text-xl font-semibold\"\u003e\u003cspan class=\"font-semibold\"\u003eTECHNICAL SUPPORT \u0026amp; RESOURCES\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.eztcp.com\/en\/products\/sig-5530\" title=\"SIG-5530 4-Port Analog Input I\/O Gateway Product Page\" rel=\"noopener\" target=\"_blank\"\u003e\u003cstrong\u003eSIG-5530 4-Port Analog Input I\/O Gateway Product Page\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.eztcp.com\/en\/download\/pds_files\/ds_sig5530en.pdf\" title=\"SIG-5530 4-Port Analog Input I\/O Gateway Datasheet\" rel=\"noopener\" target=\"_blank\"\u003e\u003cstrong\u003eSIG-5530 4-Port Analog Input I\/O Gateway Datasheet\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.eztcp.com\/en\/download\/pds_files\/sig5530en.pdf\" title=\"SIG-5530 4-Port Analog Input I\/O Gateway User Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003cstrong\u003eSIG-5530 4-Port Analog Input I\/O Gateway User Manual\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.eztcp.com\/en\/download\/pds_files\/an_modbus_tcp_en.pdf\" title=\"ModBus\/TCP Protocol ezTCP Application Note\" rel=\"noopener\" target=\"_blank\"\u003e\u003cstrong\u003eModBus\/TCP Protocol ezTCP Application Note\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca rel=\"noopener\" title=\"SIG Series I\/O Applications (Internet Switch) Application Note\" href=\"https:\/\/www.eztcp.com\/en\/download\/pds_files\/combinations_sig_en.pdf\" target=\"_blank\"\u003e\u003cstrong\u003eSIG Series I\/O Applications (Internet Switch) Application Note\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca rel=\"noopener\" title=\"ModMap User Manual\" href=\"https:\/\/www.eztcp.com\/en\/download\/pds_files\/an_modmap_en.pdf\" target=\"_blank\"\u003e\u003cstrong\u003eModMap User Manual\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/www.eztcp.com\/en\/download\/pds_files\/spFinder.zip\" title=\"spFinder : Management program for Packageware Products(for Windows)\" rel=\"noopener\" target=\"_blank\"\u003espFinder Management Program for Packageware Products (for Windows) Download\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.eztcp.com\/en\/download\/pds_files\/ModMap_21C.zip\" title=\"ModMap HMI Application for Remote I\/O Gateway (Supports Modbus\/TCP) Download\" rel=\"noopener\" target=\"_blank\"\u003e\u003cstrong\u003eModMap HMI Application for Remote I\/O Gateway (Supports Modbus\/TCP) Download\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003chr class=\"my-7 border-neutral-300 dark:border-neutral-700\"\u003e\n\u003cp class=\"overflow-wrap-anywhere mb-4 break-words text-base font-normal leading-7 last:mb-0 [li_\u0026amp;]:mb-0\"\u003e\u003cem class=\"italic\"\u003eThe SIG-5530 is designed for professional industrial applications. Basic networking knowledge and familiarity with Modbus\/TCP protocol recommended for optimal deployment.\u003c\/em\u003e\u003c\/p\u003e","brand":"Sollae Systems","offers":[{"title":"Default Title","offer_id":47501250691321,"sku":"SIG-5530-BO","price":195.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1641\/0911\/files\/sollae-systems-sig-5530-4-port-analog-input-ethernet-io-gateway-with-modbustcp-7996482.jpg?v=1773357908","url":"https:\/\/envistiamall.com\/es\/products\/sig-5530-4-port-analog-input-io-gateway-with-modbus-tcp","provider":"Envistia Mall","version":"1.0","type":"link"}