{"product_id":"systembase-scan-all-fd-serial-to-can-canfd-converter","title":"SystemBase sCAN\/all-FD RS232\/RS422\/RS485 to CAN\/CAN-FD Converter","description":"\u003ch2\u003e📋 Overview\u003c\/h2\u003e\n\u003cp\u003e\u003cspan class=\"special-order-badge\"\u003e📦 Special-Order · Ships in 1–2 Weeks\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe SystemBase sCAN\/all-FD is a high-performance industrial converter that bridges serial communication (RS232, RS422, or RS485 — user-selectable) to both Classical CAN and CAN-FD networks. Unlike the \u003ca href=\"\/es\/products\/systembase-scan-industrial-rs232-to-can-converter\" target=\"_blank\" title=\"SystemBase sCAN Industrial RS232 to CAN Converter\" rel=\"noopener\"\u003estandard sCAN\u003c\/a\u003e, which is RS232-only and Classical CAN-only, the all-FD model uses SystemBase's newly developed \u003ca href=\"\/es\/products\/systembase-sb300-serial-multi-protocol-rs232-rs422-rs485-transceiver\" target=\"_blank\" title=\"SB300 Advanced Serial Multi-Protocol RS232\/RS422\/RS485 Transceiver\" rel=\"noopener\"\u003eALL Transceiver (SB300)\u003c\/a\u003e to support any of the three serial standards from the same terminal block, and adds full CAN-FD (Flexible Data Rate) support alongside Classical CAN 2.0A\/B.\u003c\/p\u003e\n\u003cp\u003eConfiguration, live testing, and firmware upgrades are handled through the dedicated \u003cstrong\u003eCAN-FD Utility\u003c\/strong\u003e for Windows. With an industrial -40°C to 85°C operating range, ±15kV ESD protection, and built-in error-checking with DAR and ABOR options, the sCAN\/all-FD is built for factory automation, robotics, and vehicle\/industrial systems where reliability and higher CAN throughput both matter.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e🔀 CAN vs. CAN-FD — What's the Difference?\u003c\/h2\u003e\n\u003cp\u003eIf you're not sure whether you need Classical CAN or CAN-FD, here's the short version: CAN-FD is a newer, faster, higher-capacity evolution of the same CAN network your equipment already uses — and this converter supports both, so you don't have to choose in advance.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eData payload:\u003c\/strong\u003e Classical CAN carries up to 8 bytes of data per frame. CAN-FD (Flexible Data Rate) carries up to 64 bytes per frame — 8x more data in a single message.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpeed:\u003c\/strong\u003e Classical CAN tops out at 1Mbps. CAN-FD keeps the same 1Mbps (or lower) arbitration phase for network compatibility, but switches to a much faster 1–8Mbps data phase once arbitration is complete — so large amounts of data move significantly faster.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhy it matters:\u003c\/strong\u003e As modern equipment adds more sensors, drives, and control loops to a single CAN network, Classical CAN's small payload and speed ceiling can become a bottleneck. CAN-FD was developed specifically to remove that bottleneck without abandoning the reliability of the CAN standard.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatibility:\u003c\/strong\u003e CAN-FD controllers can receive Classical CAN messages, but Classical CAN-only nodes cannot understand CAN-FD frames — they'll register them as communication errors. If you're mixing CAN-FD and Classical CAN devices on the same bus, this is important to plan around.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eBecause the sCAN\/all-FD auto-detects and supports both frame types, it works whether your equipment is Classical CAN, CAN-FD, or a mix of both on separate segments.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e🎯 Applications — What Problems Does sCAN\/all-FD Solve?\u003c\/h2\u003e\n\u003cp\u003eThis converter is built for situations where either the serial interface, the CAN speed\/payload, or both, don't fit a standard converter.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePC-based CAN-FD monitoring and analysis:\u003c\/strong\u003e Connect a PC's serial port to CAN ECUs or CAN-FD equipment to monitor live traffic, capture logs, and diagnose issues using the CAN-FD Utility.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePLC-driven motor, servo, and robot control:\u003c\/strong\u003e Bridge a PLC's RS232 or RS485 output to a CAN-FD network controlling motors, servo drives, or robotic equipment — common in factory automation cells.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRetrofitting equipment with an unusual serial interface:\u003c\/strong\u003e Since RS232, RS422, and RS485 are all selectable from the same unit, one converter covers legacy RS232 gear, long-distance RS422 runs, and multi-drop RS485 networks — no need to stock three different converter models.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-bandwidth CAN applications:\u003c\/strong\u003e When a system generates more data per message or needs faster throughput than Classical CAN's 8-byte\/1Mbps ceiling allows, CAN-FD's larger payload and higher data-phase speed removes that bottleneck.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNoisy or unstable CAN\/CAN-FD networks:\u003c\/strong\u003e ABOR (Automatic Bus-Off Recovery) and DAR (Disable Auto Retransmission) reduce network congestion and speed recovery when errors occur — useful for unattended industrial installations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMixed CAN and CAN-FD environments:\u003c\/strong\u003e Since the converter auto-detects Classical CAN and CAN-FD frames, it can be deployed across systems that use either standard, or plan to migrate from one to the other.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003e⭐ Key Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eAll-in-one serial support — RS232, RS422, or RS485 selectable from the same terminal block\u003c\/li\u003e\n\u003cli\u003eSupports both Classical CAN (2.0A\/B) and CAN-FD (Flexible Data Rate)\u003c\/li\u003e\n\u003cli\u003eCAN speed up to 1Mbps; CAN-FD data phase speed up to 8Mbps\u003c\/li\u003e\n\u003cli\u003eSerial communication speed up to 921.6kbps\u003c\/li\u003e\n\u003cli\u003eCAN-FD payload up to 64 bytes per frame (vs. 8 bytes for Classical CAN)\u003c\/li\u003e\n\u003cli\u003eDedicated CAN-FD Utility for Windows — device configuration, communication testing, and firmware upgrade from one screen\u003c\/li\u003e\n\u003cli\u003eDAR (Disable Auto Retransmission) and ABOR (Automatic Bus-Off Recovery) options for network reliability\u003c\/li\u003e\n\u003cli\u003eStandard and Extended CAN ID filtering (11-bit and 29-bit) with configurable ID\/Mask\u003c\/li\u003e\n\u003cli\u003e±15kV ESD protection (HBM) plus EFT and Surge protection standards\u003c\/li\u003e\n\u003cli\u003e-40°C to 85°C industrial operating range\u003c\/li\u003e\n\u003cli\u003ePowered via 5V DC adapter or CAN VDD terminal (not simultaneously)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003e📊 Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIndustrial RS232\/RS422\/RS485 to CAN\/CAN-FD Converter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSerial Standard\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRS232 \/ RS422 \/ RS485 (user-selectable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSerial Port\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 port, 3.81mm pitch 5-pole terminal block with plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSerial Max Speed\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e921.6kbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSerial Signals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRS232: TXD, RXD | RS422: TXD+\/-, RXD+\/- | RS485: TRXD+\/-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCAN Standard\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eISO 11898-1:2015, ISO 11898-2:2016\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCAN Specification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClassical CAN (2.0A\/B) and CAN-FD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCAN Frame Format\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard 11-bit ID \/ Extended 29-bit ID\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCAN Port\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 port, 3.81mm pitch 5-pole terminal block with plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCAN Max Speed\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1Mbps (Classical CAN \/ CAN-FD arbitration phase)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCAN-FD Max Data Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8Mbps (data phase, with Bit Rate Switching)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCAN Signals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCAN_H, CAN_L, VDD+, GND\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eESD Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±15kV (HBM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eKS C 9610-4-2 (ESD), KS C 9610-4-4 (EFT), KS C 9610-4-5 (Surge)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Requirement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5V 1A DC input, approx. 0.5W consumption; via DC adapter jack or CAN VDD terminal (not both simultaneously)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Connector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOuter Ø3.5mm, Internal Ø1.35mm barrel jack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApprox. 54 × 72 × 28.4 mm (2.13 × 2.83 × 1.12 inches) W × L × H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProduct weight approx. 100g (gross weight approx. 261g)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConfiguration Utility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCAN-FD Utility (Windows 10 or later)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUtility Functions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDevice configuration, communication testing, firmware upgrade\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLED Indicators\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRDY (Red), DATA (Green), ERR (Red)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40°C to 85°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40°C to 85°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHumidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMax. 90% R.H., non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e📦 What's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e1× SystemBase sCAN\/all-FD Converter\u003c\/li\u003e\n\u003cli\u003e1× 5V 1A DC Adapter\u003c\/li\u003e\n\u003cli\u003e2× Terminal Blocks (Serial and CAN)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"special-order-note\"\u003e\n\u003cstrong\u003e📦 Special-Order Item\u003c\/strong\u003e\u003cbr\u003eThis item ships from the manufacturer's existing factory stock rather than our own warehouse — which is why we can offer it at this price while still keeping delivery quick. We receive it first and ship it to you directly from\u003cspan\u003e \u003c\/span\u003e\u003cem\u003eEnvistia Mall\u003c\/em\u003e, with delivery typically taking\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e~1–2 weeks\u003c\/strong\u003e. Because it's ordered in specifically to fill your request, we're unable to modify, cancel, or return it once the order is placed. Have a question about compatibility or specs before you buy? Just message us — happy to help.\u003c\/div\u003e\n\u003chr\u003e\n\u003ch2\u003e📌 Pinout \/ Pin Diagram\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eSerial Terminal Block (interface selected in CAN-FD Utility):\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRS232: TXD, RXD, GND\u003c\/li\u003e\n\u003cli\u003eRS422: TX+, TX-, RX+, RX-, GND\u003c\/li\u003e\n\u003cli\u003eRS485: TRX+, TRX-, GND\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCAN Terminal Block:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCAN_H, CAN_L\u003c\/li\u003e\n\u003cli\u003eGND, VDD+ (power input option)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003e🔧 Setup \/ Configuration\u003c\/h2\u003e\n\u003cp\u003eThe sCAN\/all-FD uses two 2-position DIP switch banks on the case:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSW1 (CAN Port Switch):\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eSwitch 1: ON = Active Mode (default) \/ OFF = Setup Mode (for use with CAN-FD Utility)\u003c\/li\u003e\n\u003cli\u003eSwitch 2: ON = CAN 120Ω termination resistor enabled (default) \/ OFF = disabled\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSW2 (Power Selection Switch):\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eSwitch 1: ON = DC-Jack power enabled (default) \/ OFF = disabled\u003c\/li\u003e\n\u003cli\u003eSwitch 2: ON = CAN VDD power enabled \/ OFF = disabled (default)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cblockquote\u003e\n\u003cp\u003e\u003cstrong\u003eImportant:\u003c\/strong\u003e Do not enable the DC-Jack power and CAN VDD power at the same time — supplying power from both sources simultaneously may cause serious damage to the product or the power source.\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003cp\u003eTo change settings, set SW1 switch 1 to OFF (Setup Mode), connect the serial terminal block to a PC via RS232 (fixed at 115200, 8N1 in Setup Mode), and open the CAN-FD Utility. Select Device → sCAN\/all-FD, choose the COM port, and click Connect (Setup tab) to access the Setting Page. From there you can configure CAN arbitration and data phase baud rates, standard\/extended ID filters, DAR\/ABOR options, and the serial interface, baud rate, and termination settings — then click Save. Switch SW1 switch 1 back to ON (Active Mode) to apply your changes and resume normal operation.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e💻 Software\u003c\/h2\u003e\n\u003cp\u003eThe CAN-FD Utility is SystemBase's Windows configuration tool for the sCAN\/all-FD, eCAN-FD, and uCAN\/Analyzer-FD product line. It provides a Setting Page for CAN and serial configuration, an Active Page for sending\/receiving CAN and CAN-FD frames with real-time error status (TEC\/REC\/LEC) and logging (up to 2,000 real-time or 10,000 accumulated entries), and a Firmware update function accessible from the top menu in Setup Mode.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e💡 Tips\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eNever enable DC-Jack power and CAN VDD power at the same time — pick one power source only.\u003c\/li\u003e\n\u003cli\u003eIf sCAN\/all-FD is at the end of a CAN bus segment, enable the 120Ω termination resistor via SW1 switch 2; RS422\/RS485 serial termination is set separately in the CAN-FD Utility's Serial Setting section.\u003c\/li\u003e\n\u003cli\u003eAll CAN 2.0A\/B nodes sharing the network with sCAN\/all-FD must use the same Arbitration Baudrate (max 1Mbps) — only the Data Phase Baudrate can run faster in CAN-FD mode.\u003c\/li\u003e\n\u003cli\u003eDo not perform a firmware update while CAN data is actively being received on the CAN port — this can cause critical damage to the product.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003e🚫 Limitations\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSingle serial port and single CAN port per unit — one interface must be selected in software (RS232, RS422, or RS485) rather than used simultaneously.\u003c\/li\u003e\n\u003cli\u003eCAN-FD Utility requires Windows 10 or later.\u003c\/li\u003e\n\u003cli\u003eThis device is intended for industrial use (Class A) and is not intended for use in a home or residential environment.\u003c\/li\u003e\n\u003cli\u003eClassical CAN-only nodes cannot interpret CAN-FD frames and will register them as communication errors — plan network topology accordingly if mixing CAN and CAN-FD devices.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003e📄 Documentation \u0026amp; Resources\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1641\/0911\/files\/sCAN_all-FD_Spec_Sheet_Eng.pdf?v=1786212119\" title=\"sCAN\/all-FD Spec Sheet\" rel=\"noopener\" target=\"_blank\"\u003eSpec Sheet — Full technical specifications, dimensions, and pinout\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1641\/0911\/files\/sCAN_all_FD_UserManual_Eng.pdf?v=1786212145\" title=\"sCAN\/all-FD User Manual\" rel=\"noopener\" target=\"_blank\"\u003eUser Manual — CAN\/CAN-FD overview, hardware setup, CAN-FD Utility configuration, and troubleshooting\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/en.sysbas.com\/serial-to-can\/?idx=49\" title=\"SystemBase sCAN\/all-FD Manufacturer Page\" rel=\"noopener\" target=\"_blank\"\u003eManufacturer Product Page — Specifications, app notes, downloads\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/envistiamall.com\/collections\/can-bus-converters\" title=\"CAN Bus Converters at Envistia Mall\" rel=\"noopener\" target=\"_blank\"\u003eAll CAN Bus Converters\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003cp\u003e\u003cem\u003eSold and supported by Envistia Mall. This product ships from the United States. Envistia Mall and the manufacturer are not liable for damages or losses resulting from improper installation, incorrect wiring, applying power to both power sources simultaneously, or use outside the specified operating conditions. Always verify serial and CAN wiring, power source, and bus termination before connecting to live industrial or vehicle networks, and consult the User Manual for full setup and safety guidance.\u003c\/em\u003e\u003c\/p\u003e","brand":"SystemBase","offers":[{"title":"Default Title","offer_id":48800684212473,"sku":null,"price":329.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1641\/0911\/files\/scan_all-fd-to-can-converter-1.jpg?v=1786213117","url":"https:\/\/envistiamall.com\/es\/products\/systembase-scan-all-fd-serial-to-can-canfd-converter","provider":"Envistia Mall","version":"1.0","type":"link"}